Advertisement

Arthroplasty for the Treatment of Radial Head Fractures: Indications and Current Techniques

  • Chaitanya S. Mudgal
  • James T. Monica
  • Jyoti Sharma
Chapter

Abstract

Radial head arthroplasty remains a good treatment option for fractures not amenable to fixation. Several variations exist in technique and implant type. This review discusses the insertion techniques, implant types available, and literature outcomes associated with radial head arthroplasty.

Keywords

Radial head fracture Radial head arthroplasty Radial head replacement Radial head resection Radial neck fracture Elbow fracture Terrible triad elbow 

References

  1. 1.
    Herbertsson P, Josefsson PO, Hasserius R, et al. Fractures of the radial head and neck treated with radial head excision. J Bone Joint Surg Am. 2004;86-A(9):1925–30.CrossRefGoogle Scholar
  2. 2.
    Morrey BF, Tanaka S, An KN. Valgus stability of the elbow: a definition of primary and secondary constraints. Clin Orthop Relat Res. 1991;265:187–95.Google Scholar
  3. 3.
    Ikeda M, Oka Y. Function after early radial head resection for fracture: a retrospective evaluation of 15 patients followed for 3–18 years. Acta Orthop Scand. 2000;71:191–4.CrossRefPubMedGoogle Scholar
  4. 4.
    Ring D, Quintero J, Jupiter JS. Open reduction and internal fixation of fractures of the radial head. J Bone Joint Surg Am. 2002;84:1811–5.CrossRefPubMedGoogle Scholar
  5. 5.
    Bryce CD, Armstrong AD. Anatomy and biomechanics of the elbow. Orthop Clin North Am. 2008;39:141–54.CrossRefPubMedGoogle Scholar
  6. 6.
    Johnson JA, King GJ. Anatomy and biomechanics of the elbow. In: Williams GR, Yamaguchi K, Ramsey ML, et al., editors. Shoulder and elbow arthroplasty. Philadelphia: Lippincott Williams and Wilkins; 2005. p. 279–96.Google Scholar
  7. 7.
    Bain GI, Ashwood N, Baird R, et al. Management of mason type-III radial head fractures with a titanium prosthesis, ligament repair, and early mobilization. J Bone Joint Surg Am. 2005;87:136–47.CrossRefPubMedGoogle Scholar
  8. 8.
    Technique guide from Wright Medical Technology, Inc. EVOLVE modular radial head: surgical technique guide. 2016.Google Scholar
  9. 9.
    Technique guide from DePuy Synthes. Radial head prosthesis system: surgical technique guide. 2013.Google Scholar
  10. 10.
    Judet T, Garreau de Loubresse C, Pirious P, et al. A floating prosthesis for radial- head fractures. J Bone Joint Surg Br. 1996;78:244–9.CrossRefPubMedGoogle Scholar
  11. 11.
    Technique guide from Wright. Tornier RHS radial head system: surgical technique guide. 2016.Google Scholar
  12. 12.
    Technique guide from Integra. Katalyst bipolar radial head system: surgical technique. 2011.Google Scholar
  13. 13.
    Technique guide from Stryker Howmedica Osteonics. Solar radial head: surgical technique guide. 2002.Google Scholar
  14. 14.
    Technique guide from Biomet Orthopedics. Explor modular radial head: surgical technique. 2008.Google Scholar
  15. 15.
    Technique guide from Small Bone Innovations, Inc. rHead radial implants: surgical technique. 2010.Google Scholar
  16. 16.
    Technique guide from Acumed. Anatomic radial head system: surgical technique. 2011.Google Scholar
  17. 17.
    Hotchkiss RN. Displaced fractures of the radial head: internal fixation or excision. J Am Acad Orthop Surg. 1997;5:1–10.CrossRefPubMedGoogle Scholar
  18. 18.
    Morry BF. Surgical exposures of the elbow. In: Morrey BF, editor. The elbow and its disorders. 2nd ed. Philadelphia: W.B. Sanders; 1993. p. 139–66.Google Scholar
  19. 19.
    Calfee RP, Wilson JM, Won AHW. Variations in the anatomic relations of the posterior interosseous nerve associated with proximal forearm trauma. J Bone Joint Surg Am. 2011;93(1):81–90.CrossRefPubMedPubMedCentralGoogle Scholar
  20. 20.
    Tornetta P, Hochwald N, Bono C, et al. Anatomy of the posterior interosseous nerve in relation to fixation of the radial head. Clin Orthop Relat Res. 1997;345:215–8.CrossRefGoogle Scholar
  21. 21.
    King GJW. Management of comminuted radial head fractures with replacement arthroplasty. Hand Clin. 2004;20:429–41.CrossRefPubMedGoogle Scholar
  22. 22.
    Shannon HL, Deluce SR, Giles JW, et al. The effect of radial head implant shape on radiocapitellar kinematics during in vitro forearm rotation. J Shoulder Elb Surg. 2015;24(2):258–64.CrossRefGoogle Scholar
  23. 23.
    Smith GR, Hotchkiss RN. Radial head and neck fractures: anatomic guidelines for proper placement of internal fixation. J Should Elb Surg. 1996;5(2 Pt 1):113–7.CrossRefGoogle Scholar
  24. 24.
    Van Glabbeek F, Van Riet RP, Baumfeld JA, et al. Detrimental effects of overstuffing or understuffing with a radial heal replacement in the medial collateral ligament deficient elbow. J Bone Joint Surg Am. 2004;86:2629–35.CrossRefPubMedGoogle Scholar
  25. 25.
    Doornberg JN, Linzel DS, Zurakowski D, et al. Reference points for radial head prosthesis size. J Hand Surg Am. 2006;31:53–7.CrossRefPubMedGoogle Scholar
  26. 26.
    Ring D, King G. Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability: surgical technique. J Bone Joint Surg Am. 2008;90:63–73.CrossRefPubMedGoogle Scholar
  27. 27.
    King GJ, Zarzour ZD, Rath DA, et al. Metallic radial head arthroplasty improves valgus stability of the elbow. Clin Orthop. 1999;368:114–25.CrossRefGoogle Scholar
  28. 28.
    Beingessner DM, Dunning CE, Gordon KD, et al. The effect of radial head excision and arthroplasty on elbow kinematics and stability. J Bone Joint Surg Am. 2004;86:1730–9.CrossRefPubMedGoogle Scholar
  29. 29.
    Morrey BF, Askew L, Chao EY. Silastic prosthetic replacement for the radial head. J Bone Joint Surg Am. 1981;63:454–8.CrossRefPubMedGoogle Scholar
  30. 30.
    Worsing RA Jr, Engber WD, Lange TA. Reactive synovitis from particulate silastic. J Bone Joint Surg Am. 1982;63:581–5.CrossRefGoogle Scholar
  31. 31.
    Strzepa P, Klawitter J. Ascension pyrocarbon hemisphere wear testing against bone. Poster No. 0897, 51st Annual Meeting of the Orthopaedic Research Society. Washington, DC; 2005.Google Scholar
  32. 32.
    Cook SD, Thomas KA, Kester MA. Wear characteristics of the canine acetabulum against different femoral prosthesis. J Bone Joint Surg Br. 1989;71(2):189–97.CrossRefPubMedGoogle Scholar
  33. 33.
    Moon JG, Berglund LJ, Xachary D, et al. Radiocapitellar joint stability with bipolar versus monopolar radial head prostheses. J Should Elb Surg. 2009;18(5):779–84.CrossRefGoogle Scholar
  34. 34.
    Grewal R, MacDermid JC, Faber KJ, et al. Comminuted radial head fractures treated with a modular metallic radial head arthroplasty: study of outcomes. J Bone Joint Surg Am. 2006;88:2192–200.PubMedGoogle Scholar
  35. 35.
    Harrington IJ, Sekyi-Otu A, Barrington TW, et al. The functional outcome with metallic radial head implants in the treatment of unstable elbow fractures: a long- term review. J Trauma. 2001;50:46–52.CrossRefPubMedGoogle Scholar
  36. 36.
    Doornberg JN, Parisien R, van Duijn J, et al. Radial head arthroplasty with a modular metal spacer to treat traumatic elbow instability. J Bone Joint Surg Am. 2007;89:1075–80.CrossRefPubMedGoogle Scholar
  37. 37.
    Morrey BF. The elbow and its disorders. 2nd ed. Philadelphia: Saunders; 1993.Google Scholar
  38. 38.
    Moro JK, Werier J, MacDermid JC, et al. Arthroplasty with a metal radial head for unreconstructible fractures of the radial head. J Bone Joint Surg Am. 2001;83:1202–11.CrossRefGoogle Scholar
  39. 39.
    Knight DJ, Rymaszewski LA, Amis AA, et al. Primary replacement of the fractured radial head with a metal prosthesis. J Bone Joint Surg Br. 1993;75:572–6.CrossRefPubMedGoogle Scholar
  40. 40.
    Marsh JP, Grewal R, Faber KJ, et al. Radial head fractures treated with modular metallic radial head replacement: outcomes at a mean follow-up of eight years. J Bone Joint Surg Am. 2016;98(7):527–35.CrossRefPubMedGoogle Scholar
  41. 41.
    Holmenschlager F, Halm JP, Winckler S. Fresh fractures of the radial head: results with the Judet prosthesis. Rev Chir Orthop Reparatrice Appar Mot. 2002;88:387–97. [in French].PubMedGoogle Scholar
  42. 42.
    Antuna SA, Sanchez-Marquez JM, Barco R. Long- term results of radial head resection following isolated radial head fractures in patients younger than forty years old. J Bone Joint Surg Am. 2010;92(3):558–66.CrossRefPubMedGoogle Scholar
  43. 43.
    Neuhaus V, Christoforou D, Kachooei A, et al. Radial head prosthesis removal: a retrospective case series of 14 patients. Arch Bone Joint Surg. 2015;3(2):88–93.PubMedGoogle Scholar

Copyright information

© Springer Nature Switzerland AG 2018

Authors and Affiliations

  • Chaitanya S. Mudgal
    • 1
  • James T. Monica
    • 2
  • Jyoti Sharma
    • 3
  1. 1.Hand Surgery Service, Department of Orthopedic SurgeryMassachusetts General HospitalBostonUSA
  2. 2.Department of Orthopedic SurgeryRobert Wood Johnson University Medical School, Rutgers UniversityNew BrunswickUSA
  3. 3.Department of Orthopedic SurgeryMassachusetts General HospitalBostonUSA