Advertisement

Review of Currently Available Tools of the Trade

  • Silvana Marasco
  • Jose J. DiazJr.
Chapter

Abstract

The science of chest wall injury has continued to grow. The understanding of the mechanics of the chest wall and the various injury patterns has become better understood. This has allowed surgeons to study how to improve on the management of chest wall injury. The surge in technology on implant development had been significant in the last 10 years. In addition, the concept of absorbable prostheses for the purpose of rib fractures and sternal injuries has made it to the market. Since the introduction of the laparoscope in the 1990s and the recognition of minimally invasive surgical approaches, these techniques have demonstrated improved patient outcomes. The latest advancements on chest wall injury have been related to minimally invasive approach. Surgeons are focusing on smaller incisions, sparing major muscle groups resulting in less damage, and a quicker return to function. As surgeons develop new surgical techniques and approaches, industry has had to innovate and make instruments to function in smaller sizes dementions.

Keywords

Chest wall injury Bioresorbable prostheses for chest injury Rib fracture plating system Intramedullary fixation of fractured ribs Rib splints 

References

  1. 1.
    Andriano KP, Pohjonen T, Tormala P. Processing and characterization of absorbable polylactide polymers for use in surgical implants. J Appl Biomater. 1994;5(2):133–40.CrossRefPubMedGoogle Scholar
  2. 2.
    Pietrzak WS, Sarver DR, Verstynen ML. Bioabsorbable polymer science for the practicing surgeon. J Craniofac Surg. 1997;8(2):87–91.CrossRefPubMedGoogle Scholar
  3. 3.
    Viljanen J, Pihlajamäki H, Kinnunen J, Bondestam S, Rokkanen P. Comparison of absorbable poly-L-lactide and metallic intramedullary rods in the fixation of femoral shaft osteotomies: an experimental study in rabbits. J Orthop Sci. 2001;6:160–6.CrossRefPubMedGoogle Scholar
  4. 4.
    Marasco S, Cooper J, Pick A, Kossmann T. Pilot study of operative fixation of fractured ribs in patients with flail chest. ANZ J Surg. 2009;79(11):804–8.CrossRefPubMedGoogle Scholar
  5. 5.
    Marasco SF, Davies AR, Cooper J, Varma D, Bennet V, Nevill R, Lee G, Bailey M, Fitzgerald M. Prospective randomized controlled trial of operative rib fixation in traumatic flail chest. J Am Coll Surgeons. 2013;216(5):924–32.CrossRefGoogle Scholar
  6. 6.
    Campbell N, Conaglen P, Martin K, Antippa P. Surgical stabilization of rib fractures using Inion OTPS wraps-techniques and quality of life follow up. J Trauma. 2009;67(3):596–601.CrossRefPubMedGoogle Scholar
  7. 7.
    Ito T, Kudo M, Yozu R. Usefulness of osteosynthesis device made of hydroxyapatite-poly-L-lactide composites in post-access cardiac surgery. Ann Thorac Surg. 2008;86:1905–8.CrossRefPubMedGoogle Scholar
  8. 8.
    Kawachi R, Watanabe S, Suzuki K, Asamura H. Clinical application of costal coaptation pins made of hydroxyapatite and poly-L-lactide composite for posterolateral thoracotomy. Eur J Cardiothorac Surg. 2008;34:510–3.CrossRefPubMedGoogle Scholar
  9. 9.
    Bell RB, Kindsfater CS. The use of biodegradable plates and screws to stabilize facial fractures. J Oral Maxillofac Surg. 2006;64:31–9.PubMedGoogle Scholar
  10. 10.
    Yerit KC, Hainich S, Turhani D, Klug C, Wittwer G, Ockher M, Ploder O, Undt G, Baumann A, Ewers R. Stability of biodegradable implants in treatment of mandibular fractures. Plast Reconstr Surg. 2005;115:1863–70.CrossRefPubMedGoogle Scholar
  11. 11.
    Mayberry JC, Terhes JT, Ellis TJ, Wanek S, Mullins RJ. Absorbable plates for rib fracture repair: preliminary experience. J Trauma. 2003 Nov;55(5):835–9.CrossRefPubMedGoogle Scholar
  12. 12.
    Marasco SF, Sutalo ID, Bui AV. Mode of failure of rib fixation with absorbable plates: a clinical and numerical modelling study. J Trauma. 2010;68(5):1225–33.CrossRefPubMedGoogle Scholar
  13. 13.
    Sales JR, Ellis TJ, Gillard J, Liu Q, Chen JC, Ham B, Mayberry JC. Biomechanical testing of a novel, minimally invasive rib fracture plating system. J Trauma. 2008;64(5):1270–4.CrossRefPubMedGoogle Scholar
  14. 14.
    Mohr M, Abrams E, Engel C, Long WB, Bottlang M. Geometry of human ribs pertinent to orthopaedic chest-wall reconstruction. J Biomech. 2007;40:1310–7.CrossRefPubMedGoogle Scholar
  15. 15.
    Jayle CP, Allain G, Ingrand P, Laksiri L, Bonnin E, Hajj-Chahine J, Mimoz O, Corbi P. Flail chest in polytraumatized patients: surgical fixation using stracos reduces ventilator time and hospital stay. Biomed Res Int. 2015;2015:624723.CrossRefPubMedPubMedCentralGoogle Scholar
  16. 16.
    Coonar AS, Wihlm JM, Wells FC, Qureshi N. Intermediate outcome and dynamic computerised tomography after chest wall reconstruction with the STRATOS titanium rib bridge system: video demonstration of preserved bucket-handle rib motion. Interact Cardiovasc Thorac Surg. 2011;12(1):80–1.CrossRefPubMedGoogle Scholar
  17. 17.
    Wiese MN, Kawel-Boehm N, Moreno de la Santa P, Al-Shahrabani F, Toffel M, Rosenthal R, Schäfer J, Tamm M, Bremerich J, Lardinois D. Functional results after chest wall stabilization with a new screwless fixation device. Eur J Cardiothorac Surg. 2015;47:868–75.CrossRefPubMedGoogle Scholar
  18. 18.
    Marasco S, Quayle M, Summerhayes R, Sutalo ID, Liovic P. An assessment of outcomes with intramedullary fixation of fractured ribs. J Cardiothorac Surg. 2016;11(1):126–40.CrossRefPubMedPubMedCentralGoogle Scholar
  19. 19.
    Claes L, Heigele CA. Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing. J Biomech. 1999;32:255–66.CrossRefPubMedGoogle Scholar
  20. 20.
    Lacroix D, Predergast P. A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading. J Biomech. 2002;35:1163–71.CrossRefPubMedGoogle Scholar
  21. 21.
    Helzel I, Long W, Fitzpatrick D, Madey S, Bottlang M. Evaluation of intramedullary rib splints for less-invasive stabilisation of rib fractures. Injury. 2009;40:1104–10.CrossRefPubMedGoogle Scholar
  22. 22.
    Bottlang M, Helzel I, Long W, Fitzpatrick D, Madey S. Less-invasive stabilization of rib fractures by intramedullary fixation: a biomechanical evaluation. J Trauma. 2010;68(5):1218–24.PubMedGoogle Scholar
  23. 23.
    Zaidenberg EE, Rossi LA, Bongiovanni SL, Tanoira I, Maignon G, Ranalletta M. Snapping scapular syndrome secondary to rib intramedullary fixation device. Int J Surg Case Rep. 2015;17:158–60.CrossRefPubMedPubMedCentralGoogle Scholar
  24. 24.
    Tarng Y-W, Liu Y-Y, Huang F-D, Lin H-L, Wu T-C, Chou Y-P. The surgical stabilization of multiple rib fractures using titanium elastic nail in blunt chest trauma with acute respiratory failure. Surg Endosc. 2016;30:388–39.CrossRefPubMedGoogle Scholar

Copyright information

© Springer International Publishing AG, part of Springer Nature 2018

Authors and Affiliations

  1. 1.Department of Cardiothoracic SurgeryThe Alfred HospitalMelbourneAustralia
  2. 2.Division Acute Care Surgery, Department of Surgery, R Adams Cowley Shock TraumaUniversity of Maryland School of MedicineBaltimoreUSA

Personalised recommendations