Advertisement

Removal of Pharmaceuticals from WWTP Secondary Effluent with Biofilters

  • L. Sbardella
  • A. Fenu
  • J. Comas
  • I. Rodriguez Roda
  • M. Weemaes
Conference paper
Part of the Lecture Notes in Civil Engineering book series (LNCE, volume 4)

Abstract

In this study the performances of a biological activated carbon filter (BAC) followed by an ultrafiltration step have been evaluated with specific regard to pharmaceutical active compounds removal (PhACs) from secondary effluent of wastewater treatment plant. The long-term operation of this technology resulted in overall removal (>75%) of the studied compounds. Aiming at understanding the mechanisms ruling the removal of the investigated PhACs, together with the BAC pilot plant, a lab-scale column set-up was operated. The column set-up was composed by two biotic columns and by an abiotic one. This scheme allowed to highlight the capability of biofilters to remove via biodegradation compounds which are classified as recalcitrant to biological process. On the same time, the column characterized by the combined effect of adsorption and biological activity, showed removal percentages which were not obtained neither in the standard biofilter (sand) nor in the standard granular activated carbon (abiotic) filter. In conclusion, both the results from the pilot and the lab-scale, suggested biofiltration as a viable option to improve secondary effluent quality and to efficiently remove PhACS.

Keywords

Biofiltration Pharmaceutical active compounds Biological activated carbon Ultrafiltration 

Notes

Acknowledgement

This work has been supported by the European Union’s Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement No 642904 - TreatRec ITN-EID project.

References

  1. Clara M, Kreuzinger N, Strenn B, Gans O, Kroiss H (2005) The solids retention time—a suitable design parameter to evaluate the capacity of wastewater treatment plants to remove micropollutants. Water Res 39:97–106CrossRefGoogle Scholar
  2. Gobel A, McArdell CS, Joss A, Siegrist H, Giger W (2007) Fate of sulphonamides, macrolides, and trimethoprim in different wastewater treatment technologies. Sci Total Environ 372:361–371CrossRefGoogle Scholar
  3. Verlicchi P, Al Aukidy M, Zambello E (2012) Occurence of pharmaceutical compounds in urban wastewater: removal mass load and environmental risk after secondary treatment – a review. Sci Total Environ 429:123–155CrossRefGoogle Scholar
  4. Zearley TL, Summers RS (2012) Removal of trace organic micropollutants by drinking water biological filters. Environ Sci Technol 46:9412–9419CrossRefGoogle Scholar

Copyright information

© Springer International Publishing AG 2017

Authors and Affiliations

  • L. Sbardella
    • 1
    • 2
  • A. Fenu
    • 2
  • J. Comas
    • 1
  • I. Rodriguez Roda
    • 1
  • M. Weemaes
    • 2
  1. 1.Catalan Institute for Water Research (ICRA)GironaSpain
  2. 2.Aquafin NVAartselaarBelgium

Personalised recommendations