Minimally Invasive Medical Devices and Healthcare Devices Using Microfabrication Technology

Chapter
Part of the Microsystems and Nanosystems book series (MICRONANO)

Abstract

Medical tools for use in the human body, such as catheters and endoscopic tools, usually need to be thin and small. With the progress of minimally invasive diagnostics and treatment techniques, these medical tools must not only be thin or small, but must also be capable of performing several functions. To meet these demands, microfabrication techniques such as MEMS (micro electromechanical systems) technology and related microfabrication technologies are effective. A MEMS device can incorporate several functions, such as sensor, actuator, and microelectronics. We have developed several microdevices for minimally invasive diagnostics and therapies using MEMS and related microfabrication technologies. An ultraminiature fiber-optic pressure sensor and intraluminal MRI (magnetic resonance imaging) probe have been developed for use in the human body. Active bending catheters and endoscopes using micro actuators have been developed for steering their tips without using traction of wires from outside the body. Small wearable healthcare devices which are attached on the surface of the human body have also been developed using the microfabrication technologies. A wearable blood pressure monitoring system using ultrasound and a microperfusion system using a metal needle with micro flow channel for measurement of subepidermal biological substances have been developed.

Keywords

Endoscope Catheter Medical device Healthcare device MEMS technology 

References

  1. 1.
    Totsu K, Haga Y, Esashi M (2005) Ultra-miniature fiber-optic pressure sensor using white light interferometry. J Micromech Microeng 15(1):71–75CrossRefGoogle Scholar
  2. 2.
    Matsuo M, Iijima K, Matsunaga T, Haga Y (2015) Development of hood with hydraulically variable tip diameter for endoscopic submucosal dissection. Sensors Actuators A 232:267–275CrossRefGoogle Scholar
  3. 3.
    Haga Y, Mineta T, Totsu K, Makishi W, Esashi M (2001) Development of active catheter, active guide wire and micro sensor systems. Interv Neuroradiol 7:125–130Google Scholar
  4. 4.
    Kobayashi T, Matsunaga T, Haga Y (2015) Active bending electric endoscope using shape memory alloy wires. In: Bleuer H et al (eds) New trends in medical and service robotics. Springer, Dordrecht, pp 131–139Google Scholar
  5. 5.
    Goto S, Matsunaga T, Matsuoka Y, Kuroda K, Esashi M, Haga Y (2008) Development of intravascular MRI probe applicable to catheter mounting. IEEJ Trans Sensors Micromach 128(10):389–395 (in Japanese)CrossRefGoogle Scholar
  6. 6.
    Suzuki D, Nishiyachi K, Fujita K, Maehira K, Oohashi Y, Fuwa K, Matsunaga T, Hasegawa H, Kanai H, Haga Y (2012) Development of wearable blood pressure sensor using ultrasound measurement. In: Proceedings of annual conference of Japanese society for medical and biological engineering (in Japanese)Google Scholar
  7. 7.
    Tsuruoka N, Ishii K, Matsunaga T, Nagatomi R, Haga Y (2016) Lactate and glucose measurement in subepidermal tissue using minimally invasive microperfusion needle. Biomed Microdevices 18:19Google Scholar

Copyright information

© Springer International Publishing Switzerland 2017

Authors and Affiliations

  • Y. Haga
    • 1
  • T. Matsunaga
    • 2
  • T. Kobayashi
    • 1
  • N. Tsuruoka
    • 1
  1. 1.Graduate School of Biomedical EngineeringTohoku UniversitySendaiJapan
  2. 2.Micro System Integration CenterTohoku UniversitySendaiJapan

Personalised recommendations