Abstract
Many issues related to electrodes and montages are the same with for cEEG as for routine EEG and long-term video EEG monitoring. Electrodes must be applied in a safe, reliable/reproducible, and standardized way to provide adequate spatial and temporal representation of cerebral activity. The montages used should allow for adequate visualization of activities of interest. However, there are several unique considerations for cEEG with respect to both.
Keywords
Needle Electrode Streak Artifact Seizure Detection Skin Breakdown Disposable Electrode
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
- 1.Ives JR. New chronic EEG electrode for critical/intensive care unit monitoring. J Clin Neurophysiol. 2005;22:119–23.CrossRefPubMedGoogle Scholar
- 2.Martz GU, Hucek C, Quigg M. Sixty day continuous use of subdermal wire electrodes for EEG monitoring during treatment of status epilepticus. Neurocrit Care. 2009;11:223–7.CrossRefPubMedGoogle Scholar
- 3.Das RR, Lucey BP, Chou SH, et al. The utility of conductive plastic electrodes in prolonged ICU EEG monitoring. Neurocrit Care. 2009;10:368–72.CrossRefPubMedGoogle Scholar
- 4.Vulliemoz S, Perrig S, Pellise D, et al. Imaging compatible electrodes for continuous electroencephalogram monitoring in the intensive care unit. J Clin Neurophysiol. 2009;26:236–43.CrossRefPubMedGoogle Scholar
- 5.Falco C, Sebastiano F, Cacciola L, et al. Scalp electrode placement by EC2 adhesive paste in long-term video-EEG monitoring. Clini Neurophysiol Off J Int Federation Clini Neurophysiol. 2005;116:1771–3.CrossRefGoogle Scholar
- 6.Kolls BJ, Husain AM. Assessment of hairline EEG as a screening tool for nonconvulsive status epilepticus. Epilepsia. 2007;48:959–65.CrossRefPubMedGoogle Scholar
- 7.Young GB, Sharpe MD, Savard M, Al Thenayan E, Norton L, Davies-Schinkel C. Seizure detection with a commercially available bedside EEG monitor and the subhairline montage. Neurocrit Care. 2009;11:411–6.CrossRefPubMedGoogle Scholar
- 8.Tanner AE, Sarkela MO, Virtanen J, et al. Application of subhairline EEG montage in intensive care unit: comparison with full montage. J Clini Neurophysiol Off Pub Am Electroencephal Soc. 2014;31:181–6.Google Scholar
- 9.Muraja-Murro A, Mervaala E, Westeren-Punnonen S, et al. Forehead EEG electrode set versus full-head scalp EEG in 100 patients with altered mental state. Epilepsy Behav E&B. 2015;49:245–9.CrossRefGoogle Scholar
- 10.Karakis I, Montouris GD, Otis JA, et al. A quick and reliable EEG montage for the detection of seizures in the critical care setting. J Clini Neurophysiol Off Pub Am Electroencephal Soc. 2010;27:100–5.Google Scholar
- 11.Kolls BJ, Olson DM, Gallentine WB, Skeen MB, Skidmore CT, Sinha SR. Electroencephalography leads placed by nontechnologists using a template system produce signals equal in quality to technologist-applied, collodion disk leads. J Clini Neurophysiol Off Pub Am Electroencephal Soc. 2012;29:42–9.Google Scholar
- 12.Kolls BJ, Lai AH, Srinivas AA, Reid RR. Integration of EEG lead placement templates into traditional technologist-based staffing models reduces costs in continuous video-EEG monitoring service. J Clini Neurophysiol Off Pub Am Electroencephal Soc. 2014;31:187–93.Google Scholar
Copyright information
© Springer International Publishing Switzerland 2017