Electric Arc Furnace Slag Concrete

Chapter
Part of the Green Energy and Technology book series (GREEN)

Abstract

The aim of this section is to comprehensively investigate the possibility of substituting natural aggregates with Black/Oxidizing Electric Arc Furnace (EAF) slag, at high replacement ratios, to produce structural concrete. The properties of the slag are described in detail, in terms of chemical composition, mineralogy, microstructure and physical characteristics. A review of the main physical and mechanical properties of concrete containing EAF slag is reported, analyzing the effect of the substitution on compressive and tensile strength and on elastic modulus, both for producing ordinary strength and high strength concretes. Durability-related properties in aggressive environments are also discussed, paying attention on freezing/thawing, drying/wetting conditions, and chlorides-contaminated exposure. Results showed that high substitution ratios of coarse natural aggregates are possible without decreasing mechanical properties of concrete, and on the contrary, slag use enhances concrete strength. Conversely, replacement of fine natural aggregates with fine slag seems feasible at lower substitution ratios only. Presence of calcium and magnesium oxides in the slag does not seem to represent a limit for the durability of concrete, due to their stabilization in crystalline lattice.

Keywords

Compressive Strength Coarse Aggregate Recycle Aggregate Natural Aggregate Recycle Concrete 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Notes

Acknowledgments

The authors would like to acknowledge Zerocento Srl, Calcestruzzi Zillo SpA, Cementi Candeo SpA, for their economical support and for supplying the EAF slag and cement.

References

  1. 1.
    Pasetto M, Baldo N (2011) Mix design and performance analysis of asphalt concretes with electric arc furnace slag. Constr Build Mater 125(8):3458–3468CrossRefGoogle Scholar
  2. 2.
    Wu S, Xue Y, Ye Q, Chen Y (2007) Utilization of steel slag as an aggregate for stone mastic asphalt (SMA) mixtures. Build Environ 42:2580–2585CrossRefGoogle Scholar
  3. 3.
    Motz H, Geiser J (2001) Products of steel slags an opportunity to save natural resources. Waste Manage 21:285–293CrossRefGoogle Scholar
  4. 4.
    Faleschini F, Brunelli K, Zanini MA, Dabalà M, Pellegrino C (2015) Electric arc furnace slag as coarse recycled aggregate for concrete production. J Sustain Metall. doi: 10.1007/s40831-015-0029-1 Google Scholar
  5. 5.
    Polanco JA, Manso JM, Setién J, Gonzàlez JJ (2011) Strength and durability of concrete made with electric steelmaking slag. ACI Mater J 108:196–203Google Scholar
  6. 6.
    Papayianni I, Anastasiou E (2010) Production of high-strength concrete using high volume of industrial by-products. Constr Build Mater 24:1412–1417CrossRefGoogle Scholar
  7. 7.
    Manso JM, Polanco JA, Losanez M, Gonzalez JJ (2006) Durability of concrete made with EAF slag as aggregate. Cem Concr Comp 28:528–534CrossRefGoogle Scholar
  8. 8.
    Pellegrino C, Gaddo V (2009) Mechanical and durability characteristics of concrete containing EAF slag as aggregate. Cem Concr Comp 31:663–671CrossRefGoogle Scholar
  9. 9.
    Tossavainen M, Engstrom F, Yang Q, Menad N, Larsson ML, Bjorkman B (2007) Characteristics of steel slag under different cooling conditions. Waste Manage 27(7):1335–1344CrossRefGoogle Scholar
  10. 10.
    Maslehuddin M, Sharif AM, Shameem M, Ibrahim M, Barry MS (2003) Comparison of properties of steel slag and crushed limestone aggregate concretes. Constr Build Mater 17:105–112CrossRefGoogle Scholar
  11. 11.
    Manso JM, Gonzalez JJ, Polanco JA (2004) Electric arc furnace slag in concrete. J Mater Civ Eng 16:639–645CrossRefGoogle Scholar
  12. 12.
    Pellegrino C, Faleschini F (2013) Experimental behavior of reinforced concrete beams with electric arc furnace slag as recycled. ACI Mater J 110(2):197–206Google Scholar
  13. 13.
    Pellegrino C, Cavagnis P, Faleschini F, Brunelli K (2013) Properties of concretes with black/oxidizing electric arc furnace slag aggregate. Cem Concr Compos 37:232–240CrossRefGoogle Scholar
  14. 14.
    ASTM International (2013) ASTM C33/C33M. Standard Specification for Concrete Aggregates, West ConshohockenGoogle Scholar
  15. 15.
    Manso JM, Hernández D, Losáñez MM, González JJ (2011) Design and elaboration of concrete mixtures using steelmaking slags. ACI Mater J 108(6):673–681Google Scholar
  16. 16.
    Arribas I, Santamaría A, Ruiz E, Ortega-López V, Manso JM (2015) Electric arc furnace slag and its use in hydraulic concrete. Constr Build Mater 90:68–79CrossRefGoogle Scholar
  17. 17.
    Faleschini F, Fernández-Ruíz MA, Zanini MA, Brunelli K, Pellegrino C, Hernández-Montes E (2015) High performance concrete with electric arc furnace slag as aggregate: mechanical and durability properties. Constr Build Mater 101:113–121CrossRefGoogle Scholar
  18. 18.
    Adegoloye G, Beaucour A-L, Ortola S, Noumowé A (2015) Concretes made of EAF slag and AOD slag aggregates from stainless steel process: mechanical properties and durability. Constr Build Mater 76:313–321CrossRefGoogle Scholar
  19. 19.
    Wang G, Wang Y, Gao Z (2010) Use of steel slag as a granular material: volume expansion prediction and usability criteria. J Hazard Mater 184:555–560CrossRefGoogle Scholar
  20. 20.
    ASTM International (2006) ASTM 4792-00. Standard test method for potential expansion of aggregates from hydration reactions; ASTM Committee D04 on Road and Paving Materials, West Conshohocken, PAGoogle Scholar
  21. 21.
    Kim S-W, Kim Y-S, Lee J-M, Kim K-H (2013) Structural performance of spirally confined concrete with EAF oxidizing slag aggregate. Eur J Environ Civ Engin 17(8):654–674CrossRefGoogle Scholar
  22. 22.
    Limbachiya MC, Leelawat T, Dhir RK (2000) Use of recycled concrete aggregate in high-strength concrete. Mater Struct 33:574–580CrossRefGoogle Scholar
  23. 23.
    Ajdukiewicz A, Kliszczewicz A (2002) Influence of recycled aggregates on mechanical properties of HS/HPC. Cem Concr Compos 24:269–279CrossRefGoogle Scholar
  24. 24.
    American Concrete Institute (2014) ACI Committee 318. Building code requirements for structural concrete (ACI 318-4)Google Scholar
  25. 25.
    International Federation for Structual Concrete (2008) fib Bulletin 42. Constitutive modelling of high strength/high performance concreteGoogle Scholar
  26. 26.
    Nordtest Method (1995) NT Build 443. Concrete hardened: accelerated chloride penetrationGoogle Scholar
  27. 27.
    He F, Shi C, Yuan Q, Chen C, Zheng K (2012) AgNO3-based colorimetric methods for measurement of chloride penetration in concrete. Constr Build Mater 26:1–8CrossRefGoogle Scholar
  28. 28.
    Baroghel-Bouny V, Belin P, Maultzsch M, Henry D (2007) AgNO3 spray tests: advantages, weaknesses, and various applications to quantify chloride ingress into concrete. Part 1: Non-steady-state diffusion tests and exposure to natural conditions. Mater Struct 40:759–781CrossRefGoogle Scholar

Copyright information

© Springer International Publishing Switzerland 2016

Authors and Affiliations

  1. 1.Department of Civil, Environmental and Architectural EngineeringUniversity of PaduaPaduaItaly

Personalised recommendations