Abstract

Transperineal mapping biopsy (TPMB) is a substantial improvement over transrectal ultrasound guided biopsy (TRUS) in accurate grading and lesion identification, yet lacks standardization and in its current form utilizes antiquated technology. Theoretical models demonstrate that sampling the prostate at 5 mm intervals with a 15-gauge biopsy needle would detect 2.5 mm lesions with excellent accuracy. In practice, this approach is problematic due to deflection of biopsy needles during travel into the gland, movement of the gland during respiration, and technological constraints requiring multiple sampling attempts along the same needle path to cover the full length of the prostate. To help solve these problems, a software program was created to provide a real-time 3D image of the prostate generated from intraoperative axial (transverse) image capture. This software both generates a biopsy plan designed to provide complete coverage of the gland and subsequently monitors sampling in real-time to ensure adequate coverage is obtained. Moreover, if a patient is found to have cancer amenable to targeted focal therapy, the 3D map can be utilized in the OR to locate the sites to be ablated. What follows is a detailed description of how the software works and what additional changes are necessary to overcome the current challenges facing TPMB. The increased sampling accuracy that can be obtained with 3D mapping biopsy (MB) is necessary for proper risk stratification allowing improved selection of surveillance candidates.

Keywords

Prostate cancer Three-dimensional mapping biopsy Patient selection Active surveillance 

Supplementary material

Video 6.1

(Fig. 6.8): Overview of the three-dimensional mapping biopsy procedure and software functionality (MP4 178,387 kb)

References

  1. 1.
    Kepner GR, Kepner JV. Transperineal prostate biopsy: analysis of a uniform core sampling pattern that yields data on tumor volume limits in negative biopsies. Theor Biol Med Model. 2010;17(7):23.CrossRefGoogle Scholar
  2. 2.
    Stone NN, Roy J, Hong S, Lo YC, Stock RG. Prostate gland motion and deformation caused by needle placement during brachytherapy. Brachytherapy. 2002;1:154–60.CrossRefPubMedGoogle Scholar
  3. 3.
    Brede CM, Douville NJ, Jones S. Variable correlation of grid coordinates to core location in template prostate biopsy. Curr Urol. 2013;6(4):194–8. doi: 10.1159/000343538.PubMedCentralCrossRefPubMedGoogle Scholar
  4. 4.
    Huo ASY, Hossack T, Symons JLP, et al. Accuracy of primary systematic template guided transperineal biopsy of the prostate for locating prostate cancer: a comparison with radical prostatectomy specimens. J Urol. 2012;187(6):2044–9. doi: 10.1016/j.juro.2012.01.066.CrossRefPubMedGoogle Scholar
  5. 5.
    Brawer MK. The influence of prostate volume on prostate cancer detection. Eur Urol Suppl. 2002;1(6):35–9. doi: 10.1016/S1569-9056(02)00055-6.CrossRefGoogle Scholar
  6. 6.
    Symons JL, Huo A, Yuen CL, et al. Outcomes of transperineal template‐guided prostate biopsy in 409 patients. BJU Int. 2013;112(5):585–93. doi: 10.1111/j.1464-410X.2012.11657.x.CrossRefPubMedGoogle Scholar

Copyright information

© Springer International Publishing Switzerland 2016

Authors and Affiliations

  • Kevin Krughoff
    • 1
  • Nelson N. Stone
    • 2
  • Jesse Elliott
    • 3
  • Craig Baer
    • 4
  • Paul Arangua
    • 5
  • E. David Crawford
    • 6
    Email author
  1. 1.Division of Urology, Department of SurgeryUniversity of Colorado Denver School of MedicineAuroraUSA
  2. 2.Department of UrologyThe Icahn School of Medicine at Mount SinaiNew YorkUSA
  3. 3.Software Development, BSCi, Inc.Colorado SpringersUSA
  4. 4.BCSi Inc.Colorado SpringsUSA
  5. 5.Urologic OncologyUniversity of Colorado DenverAuroraUSA
  6. 6.Radiation Oncology, University of ColoradoAuroraUSA

Personalised recommendations