Optical Coherence Tomography (OCT)

  • Axel PetzoldEmail author

Abstract

Retinal optical coherence tomography (OCT) has developed from a research tool to a validated instrument recommended for clinical use. For good clinical practice (GCP), this will require adherence to quality control (QC) criteria. This chapter will provide an overview of lessons learned from hands-on teaching of retinal OCT to a broad audience at a number of centers, both neurological and ophthalmological, and international teaching courses. The chapter will also highlight practical QC points as relevant to working together with a reading center for clinical studies and trials.

Keywords

OCT Protocol Hands on Training Visual fixation Guidelines Quality control 

Supplementary material

Video 3.1

Video showing correct placement of the OCT measurement beam to the center of the pupil and artifacts related to off-center placement (Reproduced with permission from Balk et al. [14].) (MP4 148502 kb)

References

  1. 1.
    Frohman E, Costello F, Zivadinov R, et al. Optical coherence tomography in multiple sclerosis. Lancet Neurol. 2006;5:853–63.CrossRefPubMedGoogle Scholar
  2. 2.
    Petzold A, de Boer JF, Schippling S, et al. Optical coherence tomography in multiple sclerosis: a systematic review and meta-analysis. Lancet Neurol. 2010;9:921–32.CrossRefPubMedGoogle Scholar
  3. 3.
    Saidha S, Calabresi PA. Optical coherence tomography should be part of the routine monitoring of patients with multiple sclerosis: yes. Mult Scler. 2014;20:1296–8.CrossRefPubMedGoogle Scholar
  4. 4.
    Costello FE. Optical coherence tomography technologies: which machine do you want to own?”. J Neuroophthalmol. 2014;34(Suppl):S3–9.CrossRefPubMedGoogle Scholar
  5. 5.
    Petzold A. Optical coherence tomography to assess neurodegeneration in multiple sclerosis. Methods Mol Biol. 2014;153 ff. doi: 10.1007/7651_2014_153 Google Scholar
  6. 6.
    Tewarie P, Balk L, Costello F, Green A, Martin R, et al. The OSCAR-IB consensus criteria for retinal OCT quality assessment. PLoS One. 2012;7, e34823.PubMedCentralCrossRefPubMedGoogle Scholar
  7. 7.
    Schippling S, Balk L, Costello F, et al. Quality control for retinal OCT in multiple sclerosis: validation of the OSCAR-IB criteria. Mult Scler. 2014;21(2):163–70.CrossRefPubMedGoogle Scholar
  8. 8.
    Uhthoff W. Untersuchungen über den Einfluss des chronischen Alkoholismus auf das menschliche Sehorgan. Archiv für Ophthalmologie. 1886;32:95–188.Google Scholar
  9. 9.
    Ogden TE. Nerve fiber layer of the primate retina: morphometric analysis. Invest Ophthalmol Vis Sci. 1984;25:19–29.PubMedGoogle Scholar
  10. 10.
    Plant GT, Perry VH. The anatomical basis of the caecocentral scotoma. New observations and a review. Brain. 1990;113(Pt 5):1441–57.CrossRefPubMedGoogle Scholar
  11. 11.
    Petzold A. CSF biomarkers for improved prognostic accuracy in acute CNS disease. Neurol Res. 2007;29:691–708.CrossRefPubMedGoogle Scholar
  12. 12.
    Kupersmith MJ, Anderson S, Durbin MK, Kardon RH. Scanning laser polarimetry, but not optical coherence tomography predicts permanent visual field loss in acute non-arteritic anterior ischemic optic neuropathy. Invest Ophthalmol Vis Sci. 2013;54:5514–9.PubMedCentralCrossRefPubMedGoogle Scholar
  13. 13.
    Petzold A, Wattjes MP, Costello F, et al. The investigation of acute optic neuritis: a review and proposed protocol. Nat Rev Neurol. 2014;10:447–58.CrossRefPubMedGoogle Scholar
  14. 14.
    Balk LJ, de Vries–Knoppert WAEJ, Petzold A. A simple sign for recognizing off–axis OCT measurement beam placement in the context of multicentre studies. PLoS One. 2012;7(11), e48222.PubMedCentralCrossRefPubMedGoogle Scholar
  15. 15.
    Domalpally A, Danis RP, Zhang B, et al. Quality issues in interpretation of optical coherence tomograms in macular diseases. Retina. 2009;29:775–81.CrossRefPubMedGoogle Scholar
  16. 16.
    Talman LS, Bisker ER, Sackel DJ, et al. Longitudinal study of vision and retinal nerve fiber layer thickness in multiple sclerosis. Ann Neurol. 2010;67:749–60.PubMedCentralPubMedGoogle Scholar
  17. 17.
    Balk L, et al. Retinal ganglion cell injury in MS occurs most rapidly early in the course of disease. Multiple Sclerosis J. 2014;20(S1):PS8.3.Google Scholar
  18. 18.
    Gabriele ML, Ishikawa H, Wollstein G, et al. Optical coherence tomography scan circle location and mean retinal nerve fiber layer measurement variability. Invest Ophthalmol Vis Sci. 2008;49:2315–21.PubMedCentralCrossRefPubMedGoogle Scholar
  19. 19.
    Balasubramanian M, Bowd C, Vizzeri G, et al. Effect of image quality on tissue thickness measurements obtained with spectral domain-optical coherence tomography. Opt Express. 2009;17:4019–36.PubMedCentralCrossRefPubMedGoogle Scholar
  20. 20.
    Petzold A, Balcer L, Calabresi P, et al. OCT in a multi–centre setting: quality control issues. In: Calabresi P, Balcer L, Frohman E, editors. Optical coherence tomography in neurological disease. New York: Cambridge University Press; 2015. p. 103–13.Google Scholar
  21. 21.
    Evangelou N, Konz D, Esiri MM, et al. Size-selective neuronal changes in the anterior optic pathways suggest a differential susceptibility to injury in multiple sclerosis. Brain. 2001;124:1813–20.CrossRefPubMedGoogle Scholar
  22. 22.
    Hariri A, Lee SY, Ruiz-Garcia H, et al. Effect of angle of incidence on macular thickness and volume measurements obtained by spectral-domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2012;53:5287–91.CrossRefPubMedGoogle Scholar
  23. 23.
    Hutchinson M. Optical coherence tomography should be part of the routine monitoring of patients with multiple sclerosis: commentary. Mult Scler. 2014;20:1302–3.CrossRefPubMedGoogle Scholar

Copyright information

© Springer International Publishing Switzerland 2016

Authors and Affiliations

  1. 1.Department of Neuro-ophthalmologyMoorfields Eye Hospital & National Hospital of Neurology and NeurosurgeryLondonUK
  2. 2.Department of NeuroimmunologyUCL Institute of NeurologyLondonUK
  3. 3.Dutch Expertise Center Neuro-Ophthalmology, Departments of Neurology and OphthalmologyVU Medical CenterAmsterdamThe Netherlands

Personalised recommendations