Application of Diffuse Optical Reflectance to Measure Myocardial Wall Thickness and Presence of Infarct Scar: A Monte Carlo Simulation Study
Abstract
Catheter ablation in patients suffering from chronic arrhythmias often requires detailed knowledge of the specific myocardial anatomy underlying the catheter tip to guide the delivery of the ablating RF energy. Such information is often lacking in a clinical procedure. In this study, we present a proof-of-concept computational investigation into the potential for using an optical strategy, based-on diffuse optical reflectance, to provide quantitative anatomical measures of underlying myocardial wall thickness and presence of scar. In detailed Monte Carlo simulations of light scattering, significant changes in peak height and FWHM of radial profiles of diffusely reflected light were seen with both changes in tissue thickness and presence of underlying scar. Such changes were seen to occur to different degrees for different wavelengths of light. In conclusion, our findings suggest that examining the ratio of these changes between different wavelengths may provide the potential basis for an optical-catheter to map underlying cardiac anatomy and guide ablation in the clinic.
Keywords
Peak Height Radial Profile Tissue Thickness Healthy Myocardium Relative Peak HeightReferences
- 1.Bunch, T., Asirvatham, S., Friedman, P., Monahan, K., Munger, T., Rea, R., Sinak, L., Packer, D.: Outcomes after cardiac perforation during radiofrequency ablation of the atrium. J. Cardiovasc. Electrophysiol. 16, 1172–1179 (2005)CrossRefGoogle Scholar
- 2.Stevenson, W.: Ventricular tachycardia after myocardial infarction: from arrhythmia surgery to catheter ablation. J. Cardiovasc. Electrophysiol. 6, 942–950 (1995)CrossRefGoogle Scholar
- 3.Stevenson, W.G., Soejima, K.: Catheter ablation for ventricular tachycardia. Circulation 115, 2750–2760 (2007)CrossRefGoogle Scholar
- 4.Wright, M., Harks, E., Deladi, S., Suijver, F., Barley, M., van Dusschoten, A., Fokkenrood, S., Zuo, F., Sacher, F., Hocini, M., Haissaguerre, M., Jais, P.: Real-time lesion assessment using a novel combined ultrasound and radiofrequency ablation catheter. Heart Rhythm 8, 304–312 (2011)CrossRefGoogle Scholar
- 5.Cheong, W.F., Prahl, S.A., Welch, A.J.: A review of the optical properties of biological tissues. IEEE Quant. Electron. 26, 2166–2185 (1990)CrossRefGoogle Scholar
- 6.Gibson, A., Hebden, J., Arridge, S.: Recent advances in diffuse optical imaging. Phys. Med. Biol. 50, R1–R43 (2005)CrossRefGoogle Scholar
- 7.Wang, L., Jacques, S.L., Zheng, L.: MCML–Monte carlo modeling of light transport in multi-layered tissues. Comput. Methods Programs Biomed. 47, 131–146 (1995)CrossRefGoogle Scholar
- 8.Bishop, M.J., Bub, G., Garny, A., Gavaghan, D.J., Rodriguez, B.: An investigation into the role of the optical detection set-up in the recording of cardiac optical mapping signals: a Monte Carlo simulation study. Physica D 238, 1008–1018 (2009)MATHMathSciNetCrossRefGoogle Scholar
- 9.Walton, R.D., Benoist, D., Hyatt, C.J., Gilbert, S.H., White, E., Bernus, O.: Dual excitation wavelength epifluorescence imaging of transmural electrophysiological properties in intact hearts. Heart Rhythm 7, 1843–1849 (2010)CrossRefGoogle Scholar
- 10.Splinter, R., Svenson, R.H., Littmann, L., Tuntelder, J.R., Chuang, C.H., Tatsis, G.P., Thompson, M.: Optical properties of normal, diseased, and laser photocoagulated myocardium at the Nd: YAG wavelength. Lasers Surg. Med. 11, 117–124 (1991)CrossRefGoogle Scholar
- 11.Bishop, M.J., Plank, G.: Simulating photon scattering effects in structurally detailed ventricular models using a Monte Carlo approach. Front. Physiol. 5, 1–14 (2014)CrossRefGoogle Scholar