Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 47))

  • 2112 Accesses

Abstract

To investigate the hemodynamic performance of overlapping bare-metal stents treatment of thoracic aortic aneurysms (TAA), three simplified geometric models, named, no stent, with one single stent and two overlapped stents were studied and compared in terms of velocity profiles and wall shear stress (WSS) distributions by means of computational fluid dynamics (CFD). The results showed that overlapping bare-metal stents intervention significantly decreased the WSS and the blood flow velocity in the aneurysm sac, meanwhile the vortex in the sac became weaker and weaker. The results indicated that overlapping stents intervention may effectively isolate the thoracic aortic aneurysm, protecting it from rupture. In conclusion, overlapping bare-metal stents may serve a similar purpose to that of the multilayer flow modulator (MFM) manufactured by Cardiatis SA (Isnes, Belgium).

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2015 Springer International Publishing Switzerland

About this paper

Cite this paper

Zhang, P., Sun, A.Q., Zhan, F., Deng, X.Y. (2015). Overlapping Bare-Metal Stents Strategy in Treatment of Thoracic Aortic Aneurysm: A Numerical Study. In: Su, FC., Wang, SH., Yeh, ML. (eds) 1st Global Conference on Biomedical Engineering & 9th Asian-Pacific Conference on Medical and Biological Engineering. IFMBE Proceedings, vol 47. Springer, Cham. https://doi.org/10.1007/978-3-319-12262-5_16

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-12262-5_16

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-12261-8

  • Online ISBN: 978-3-319-12262-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics