Advertisement

A Transient Response Domain Time Analysis Method of Transmission Lines

  • Hong-bo Dou
  • Yun-feng Hua
  • An-xin Qi
  • Jing XuEmail author
  • Jin-quan Zhao
Conference paper
Part of the Advances in Intelligent Systems and Computing book series (AISC, volume 1075)

Abstract

In this paper, we presented a new time domain method to analyze the transient response of transmission lines. This method first discretizes telegraph equations in domain time by difference, then establishes a first order differential equation with respect to space, next using the precise integration method to receive the transient response of the transmission lines. This is a semi analytic numerical method in domain time. This method has advantages of simple, accurate and efficient which can be used to analyze the transient response of the lossy transmission lines with nonlinear load efficiently. It also can be used to analyze transient response of power transmission lines and detect the fault location.

Keywords

Transmission lines Transient response Domain time analysis Nonlinear load 

References

  1. 1.
    Li, H., Li, Z.: Efficient numerical method for simulating transient response of interconnect lines in high speed VLSI. J. Shanghai Jiaotong Univ. 35(6), 817–819 (2001)Google Scholar
  2. 2.
    Zhao, J., Zhou, X., Jiang, L., Fan, N.: Transient response sensitivity analysis of transmission line network. J. Circ. Syst. 18(01), 318–321 (2013)Google Scholar
  3. 3.
    Cao, C.: Time step integration method for transient response of non-uniform lossy multiconductor transmission line. Xi’an DianZi University (2012)Google Scholar
  4. 4.
    Shao, Y.: Electrothermal transient analysis of interconnection based on transmission line network. Shanghai Jiaotong University (2012)Google Scholar
  5. 5.
    Xie, L., Lei, Y.: Transient electromagnetic response of multi-conductor transmission line in electrical system. Chin. J. Electr. Technol. 25(05), 190–194 (2010)Google Scholar
  6. 6.
    Fang, X., Zhu, Z., Zhang, M., Li, Y.: Transient analysis of nonparallel multiconductor transmission line with arbitrary section. J. Microwave Sci. 33(01), 5–10+15 (2017)Google Scholar
  7. 7.
    Zhang, Y., Cai, Z., Zhang, H.: Study on transient response of multi-conductor transmission line. J. Radio Sci. 29(02), 377–384 (2014)Google Scholar
  8. 8.
    Zhao, J., Ma, X., Ma, G.: A precise integration method for time domain response of arbitrary load loss transmission lines. Microelectronics 31(6), 431–436 (2001)Google Scholar
  9. 9.
    Mao, J., Li, Z.: Properties and analysis of transient response of loss coupled transmission lines. J. Microwaves 33(2), 25–31 (1993)Google Scholar
  10. 10.
    Zhong, W.: Fine calculation method of transient history. Comput. Struct. Mech. Appl. 12(1), 16 (1999)Google Scholar

Copyright information

© Springer Nature Switzerland AG 2020

Authors and Affiliations

  • Hong-bo Dou
    • 1
  • Yun-feng Hua
    • 1
  • An-xin Qi
    • 1
  • Jing Xu
    • 2
    Email author
  • Jin-quan Zhao
    • 2
  1. 1.Shaanxi Regional Electric Power Group Co., Ltd.BaojiChina
  2. 2.Xi’an JiaoTong UniversityXi’anChina

Personalised recommendations