Investigation and Experimental Evaluation of Vapor Compression Refrigeration System by Means of Alternative Refrigerants

  • Nilam P. JadhavEmail author
  • V. K. Bupesh Raja
  • Suhas P. Deshmukh
  • Mandar M. Lele
Conference paper
Part of the Lecture Notes on Data Engineering and Communications Technologies book series (LNDECT, volume 35)

Abstract

A theoretical investigation is considered to discover possible alternatives on behalf of R134a, R12 and R22 for traditional vapor compression refrigeration system. For the same two azeotrope blends, R404A and R407C are nominated. The theoretical analysis is conceded for the refrigerating system at a continual condensation temperature of 50 ℃ and −10 ℃ to 10 ℃ evaporating temperature. Results to investigate alternative refrigerant have slightly lower performance coefficient than HFC134a, CFC22 and CFC12 respectively. Further, it is noticed the average performance coefficient of alternative refrigerants is 7.26% for R404A and 1.41% for R407C enhanced for the degree of superheating and sub cooling. The experimental setup is developed for R404A and R407C to observed different parameters such as pull down time for evaporator temperature, discharge pressure, power consumption, performance coefficient and energy efficiency ratio and compared with R134a. Smaller pull down time, lesser power consumption and isentropic work done improves the performance coefficient of the system, similar or maybe higher behavior like R134a proved that the nominated refrigerants used as an alternative to R12 and R22.

Keywords

Refrigeration Alternative refrigerants Performance Degrees of superheat Degree of sub cooling 

References

  1. 1.
    Domanski, P.A., Brown, J.S., Heo, J., Wojtusiak, J., McLinden, M.O.: A thermodynamic analysis of refrigerants: performance limits of the vapor compression cycle. Int. J. Refrig 38, 71–79 (2013)CrossRefGoogle Scholar
  2. 2.
    Ferreira, C.A.I., Newell, T.A., Chato, J.C., Nan, X.: R404A condensing under forced flow conditions inside smooth, micro fin and cross-hatched horizontal tubes. Int. J. Refrig 26, 433–441 (2003)CrossRefGoogle Scholar
  3. 3.
    Patil, P.A.: Performance analysis of HFC-404A vapor compression refrigeration system using shell and U-tube smooth and micro fin tube condensers. J. Thermal Energy Gener. 25, 77–91 (2012)Google Scholar
  4. 4.
    Chinnaraj, C., Vijayan, R., Govindarajan, P.: Analysis of eco-friendly refrigerants usage in air conditioner. Am. J. Environ Sci. 7, 510–514 (2011)CrossRefGoogle Scholar
  5. 5.
    Jerald, A.L., Senthilkumaran, D.: Investigations on the performance of vapor compression system retrofitted with zeotropic refrigerant R404A. Am. J. Environ Sci. 10(1), 35–43 (2014)CrossRefGoogle Scholar
  6. 6.
    Shilliday, J.A., Tassou, S.A., Shilliday, N.: Comparative energy and exergy analysis of R744, R404A and R290 refrigeration cycles. Int. J. Low-Carbon Technol. 4, 1–8 (2009)CrossRefGoogle Scholar
  7. 7.
    Chen, G.M., Han, X.H., Wang, Q., Zhu, Z.W.: Cycle performance study on R32/R125/R161 as an alternative refrigerant to R407C. Appl. Therm. Eng. 17, 2559–2565 (2007)Google Scholar
  8. 8.
    ISO, International Standard Organization, International Standard-8187, household refrigerating applications (refrigerators/freezers) characteristics and test methods (1991)Google Scholar
  9. 9.
    Dalkilic, A.S., Wongwises, S.: A performance comparison of vapor-compression refrigeration system using various alternative refrigerants. Int. Commun. Heat Mass Transf. 37, 1340–1349 (2010)CrossRefGoogle Scholar
  10. 10.
    Thangavel, P., Somasundaram, P.: Part load performance analysis of vapor compression refrigeration system with hydrocarbon refrigerants. J. Sci. Ind. Res. 72, 454–460 (2013)Google Scholar
  11. 11.
    Tiwari, A., Gupta, R.C.: Experimental study of R404A and R134a in domestic refrigerator. Int. J. Eng. Sci. Technol. 3, 6390–6393 (2001)Google Scholar
  12. 12.
    Li, H., Zhao, Z.: Analysis of the operating characteristics of a low evaporation temperature R404A refrigeration system. In: International Refrigeration and Air conditioning conference, Purdue University (2008). (2221-1-6)Google Scholar

Copyright information

© Springer Nature Switzerland AG 2020

Authors and Affiliations

  • Nilam P. Jadhav
    • 1
    Email author
  • V. K. Bupesh Raja
    • 1
  • Suhas P. Deshmukh
    • 3
  • Mandar M. Lele
    • 2
  1. 1.Department of Mechanical EngineeringSathyabama UniversityChennaiIndia
  2. 2.Department of Mechanical Engineering, MIT COESPPUPuneIndia
  3. 3.Department of Mechanical EngineeringGovt. COE, KaradKaradIndia

Personalised recommendations