Advertisement

Innovation in Heat and Cooling

  • Y. H. Venus LunEmail author
  • S. L. Dennis Tung
Chapter
Part of the Green Energy and Technology book series (GREEN)

Abstract

This chapter aims to examine the design of innovative heat pump for indoor air quality, thermal comfort, energy saving, and environmental protection. To begin, the heat pump as primary air handling with precision constant temperature and humidity control is presented. The heat pump PAU unit is an innovative product aims at efficiency improvement. Then, heat pump with DX heat recovery system is discussed. The heat recovery system not only reuses waste heat to contribute to remove undesired by-product of the cooling and heating system, but also improves the overall system efficiency. The air-to-air heat exchanger as energy recovery is also discussed. The benefit of using air-to-air heat exchanger is that hot or cold air can be transported through a cross-sectional area with no additional power input to the system except for the fan power to drive the air streams. The use of air-to-air heat exchanger for cooling and heating is the most energy efficiency. To extend the application of air-to-air heat exchange, the multiple-stage heat pump with air-to-air heat exchanger is examined. Furthermore, a case study of air-to-air heat exchanger is present to better understand the application of energy recover system.

Keywords

Innovation heat pump Energy recovery DX heat recovery system Air-to-air heat exchanger Multiple-stage heat pump 

Nomenclature

h

Enthalpy

\(\dot{m}\)

Mass flow rate

ρ

Density

D

Demand for energy (heating/cooling)

Q

Volume flow rate

w

Humidity ratio

Subscript

c

Cooling (total)

h

Heating

l

Latent cooling

ls

Latent and sensible cooling

tot

Total

References

  1. 1.
    Aprea C, Mastrullo R, Ronno C (2004) Fuzzy control of the compressor speed in a refrigerant plan. Int J Refrig 27:639–648CrossRefGoogle Scholar
  2. 2.
    Zubair SM, Bahel V (1989) Compressor capacity modulation schemes. Heating Pip Air Conditioning 1989:135–143Google Scholar
  3. 3.
    Canby CS, Hepbasli A, Gokcen G (2004) Evaluating performance indices of a shopping centre and implementing HVAC control principles to minimize energy usage. Energy Build 36:587–598CrossRefGoogle Scholar
  4. 4.
    Ahem O (1991) DDC applications in variable-water systems. ASHARE Trans 97(1):751–758Google Scholar
  5. 5.
    Tillack L, Rishel JB (1998) Proper control of HVAC variable speed pumps. ASHARE J 40(11):41–47Google Scholar
  6. 6.
    Bynum H, Merwin E (1999) Variable flow: a control engineer’s perspective. ASHARE J 41(1):26–30Google Scholar
  7. 7.
    Yan G, Jia Q, Bai T (2016) Experimental investigation on vapor injection heat pump with a newly designed twin rotary variable speed compressor for cold regions. Int J Refrig 62:232–241CrossRefGoogle Scholar
  8. 8.
    Guo Y, Li G, Cheng H, Hu Y, Shen L, Li H, Hu M, Li J (2017) Development of a virtual variable-speed compressor power sensor for variable speed refrigerant flow air condition system. Int J Refrig 74:73–85CrossRefGoogle Scholar
  9. 9.
    Wepfer WJ, Shelton SV (1990) Chilled water loop optimization. ASHARE Trans 96(2):656–661Google Scholar
  10. 10.
    Hartman TB (1995) Global optimization strategies for high-performance control. ASHARE Trans 101(2):679–687Google Scholar
  11. 11.
    Chen W, Chan M, Deng S, Yan H, Weng W (2018) A direct expansion based enhanced dehumidification air conditioning system for improved year-round indoor humidity control in hot and humid climates. Build Environ 139:95–109CrossRefGoogle Scholar
  12. 12.
    Chen W, Chan MY, Weng W, Yan H, Deng S (2018) An experimental study on the operational characteristics of a direct expansion based enhanced dehumidification air conditioning system. Appl Energy 225:922–933CrossRefGoogle Scholar
  13. 13.
    Liang C, Zhang L, Pei L (2010) Performance analysis of a direct expansion air dehumidification system combined with membrane-based total heat recovery. Energy 35(9):3891–3901CrossRefGoogle Scholar
  14. 14.
    Ebrahimi K, Jones GF, Fleischer AS (2014) A review of data centre cooling technology, operating conditions and the corresponding low-grade waste heat recovery opportunities. Renew Sustain Energy Rev 31:622–638CrossRefGoogle Scholar
  15. 15.
    Francisco M, Mario P, Eloy G, Fernando D, Ruth M (2003) Design and experimental study of a mixed energy recovery system heat pipe and indirect evaporative equipment for air conditioning. Energy Build 35:1021–1030CrossRefGoogle Scholar
  16. 16.
    Zhang H, Zhuang J (2003) Research development and industrial application of heat pipe technology in China. Appl Therm Eng 23:1067–1083CrossRefGoogle Scholar
  17. 17.
    Ong KS, Haider-E-Alahi M (2003) Performance of a R-137a filled thermosyphon. Appl Therm Eng 23:2373–2381CrossRefGoogle Scholar
  18. 18.
    Mostafa A, Adb EB, Mousa MM (2007) Heat pipe heat exchanger for heat recovery in air conditioning. Appl Therm Eng 27:795–801CrossRefGoogle Scholar
  19. 19.
    IEA (International Energy Agency) (2012) Industrial heat pump. IEA Heat Pump Centre Newsl 30(1):15Google Scholar
  20. 20.
    Dincer I, Kanoglu M (2010) Refrigeration system and application. Wiley, New YorkCrossRefGoogle Scholar

Copyright information

© Springer Nature Switzerland AG 2020

Authors and Affiliations

  1. 1.Sustainable Energy LimitedHong KongPR China
  2. 2.Sustainable Energy LimitedHong KongPR China

Personalised recommendations