Advertisement

Deep Lasers on Hard Tissue and Laser Prevention in Oral Health

  • Carlo Francesco Sambri
  • Gianfranco Semez
Chapter
  • 44 Downloads

Abstract

The use of deep lasers on hard dental tissues to treat dental hypersensitivity and prevention by sealing with laser integrated procedures. Hypersensitivity is a common problem for many patients in our offices, and management is quite complex. Deep lasers such as Nd:YAG and diode laser can be used, with different techniques and different clinical approaches in our daily practice. The importance of using chromophore and desensitized chemical products, in addition to laser beam, seems to be strongly recommended. Results on clinical studies and medium-term evaluation show that these procedures are safe, efficient, and time-saving in expert hands.

Keywords

Nd:YAG Diode laser Dental hypersensitivity Laser sealing PDT 

References

  1. 1.
    Farmakis ET, Kozyrakis K, Khabbaz MG, Schoop U, Beer F, Moritz A. In vitro evaluation of dentin tubule occlusion by Denshield and Neodymium-doped yttrium-aluminum-garnet laser irradiation. J Endod. 2012;38(5):662–6.  https://doi.org/10.1016/j.joen.2012.01.019. Epub 2012 Mar 11.CrossRefPubMedGoogle Scholar
  2. 2.
    Reddy GV, Akula S, Malgikar S, Babu PR, Reddy GJ, Josephin JJ. Comparative scanning electron microscope analysis of diode laser and desensitizing toothpastes for evaluation of efficacy of dentinal tubular occlusion. J Indian Soc Periodontol. 2017;21(2):102–6.  https://doi.org/10.4103/jisp.jisp_153_17.CrossRefPubMedPubMedCentralGoogle Scholar
  3. 3.
    Gojkov-Vukelic M, Hadzic S, Zukanovic A, Pasic E, Pavlic V. Application of diode laser in the treatment of dentine hypersensitivity. Med Arch. 2016;70(6):466–9.  https://doi.org/10.5455/medarh.2016.70.466-469.CrossRefPubMedPubMedCentralGoogle Scholar
  4. 4.
    Yaghini J, Mogharehabed A, Safavi N, Mohamadi M, Ashtiju F. Evaluation of the effect of low level laser therapy toothbrush in treatment of dentin hypersensitivity. J Lasers Med Sci. 2015;6(2):85–91.PubMedPubMedCentralGoogle Scholar
  5. 5.
    Saluja M, Grover HS, Choudhary P. Comparative morphologic evaluation and occluding effectiveness of Nd: YAG, CO2 and diode lasers on exposed human dentinal tubules: an in vitro SEM study. J Clin Diagn Res. 2016;10(7):ZC66–70.  https://doi.org/10.7860/JCDR/2016/18262.8188. Epub 2016 Jul 1.CrossRefPubMedPubMedCentralGoogle Scholar
  6. 6.
    Cury MS, Silva CB, Nogueira RD, Campos MGD, Palma-Dibb RG, Geraldo-Martins VR. Surface roughness and bacterial adhesion on root dentin treated with diode laser and conventional desensitizing agents. Lasers Med Sci. 2018;33(2):257–62.  https://doi.org/10.1007/s10103-017-2356-x. Epub 2017 Oct 14.CrossRefPubMedGoogle Scholar
  7. 7.
    Bortolotto T, Mast P, Krejci I. Laser-prepared and bonding-filled fissure sealing: SEM and OCT analysis of marginal and internal adaptation. Dent Mater J. 2017;36(5):622–9.  https://doi.org/10.4012/dmj.2016-025. Epub 2017 Aug 24.CrossRefPubMedGoogle Scholar
  8. 8.
    Ozel E, Tuna EB, Firatli E. The effects of cavity-filling techniques on microleakage in class II resin restorations prepared with Er:YAG laser and diamond bur: a scanning electron microscopy study. Scanning. 2016;38(5):389–95.  https://doi.org/10.1002/sca.21282. Epub 2015 Nov 5.CrossRefPubMedGoogle Scholar