Advertisement

Non-invasive Haemoglobin Measurement Using Photoplethysmographic Technique

  • S. Selva Nidhyananthan
  • R. Dharshana ShahiniEmail author
  • S. Hari Priya
Conference paper
Part of the Lecture Notes on Data Engineering and Communications Technologies book series (LNDECT, volume 33)

Abstract

The important component for complete blood count is haemoglobin. The normal Hemoglobin (Hb) concentration in blood is about 12–15 gm/dl for females, 13.5–17.5 gm/dl for males and 11 to 16 g/dl for children. The invasive methods are used to measure the Haemoglobin concentration by ejecting the blood from the patient and subsequently analyzed. The disadvantages of the invasive methods are it causes delay between the blood collection and its analysis causes pain while ejecting the blood and the temperature should be maintained for the blood samples during transportation. The non-invasive method overcomes these disadvantages by pain free analysis of the blood, real time analysis. Proposed technique has 96.56% accuracy compared to clinical measurements.

Keywords

Haemoglobin Near infrared Non-invasive 

References

  1. 1.
    Mohamed Abbas, A., Ashok, S., Prabhu Kumar, S., Balavenkateswarlu, P.: Haemoglobin detection in blood by signal to image scanning using Photo-Plethysmo-Graphic-Technique (PPG). Indian J. Sci. Technol. 9(1) (2016).  https://doi.org/10.17485/ijst/2016/v9i1/85764
  2. 2.
    Sharma, P., Kumar, A., Kumar, G., Sanjana, Km.: Estimation of haemoglobin using optical sensor based system. Int. J. Adv. Res. Electr. Electron. Instrum. Eng. 7(4) (2018)Google Scholar
  3. 3.
    Kraitl, J., Timm, U., Ewald, H., Lewis, E.: Non-invasive sensor for an in vivo hemoglobin measurement. In: SENSORS 2011. IEEE (2011)Google Scholar
  4. 4.
    Bobade, C.D., Patil, M.S.: Non-invasive monitoring of glucose level in blood using near-infrared spectroscopy. Int. J. Recent Trends Eng. Res. (IJRTER) 02(06) (2016)Google Scholar
  5. 5.
    Padma, T., Jahnavi, P.: Non-invasive haemoglobin estimation through embedded technology on mobile application. Int. J. Appl. Eng. Res. 13(10) (2018). ISSN 0973-4562Google Scholar
  6. 6.
    Buda, R.A., Mohd. Addi, M.: A portable non-invasive blood glucose monitoring device. In: IEEE Conference on Biomedical Engineering and Sciences, 8–10 December 2014, Miri (2014)Google Scholar
  7. 7.
    Timm, U., Lewis, E., McGrath, D., Kraitl, J., Ewald, H.: LED based sensor system for non-invasive measurement of the haemoglobin concentration in human blood. In: ICBME 2008, Proceedings 23, pp. 825–828 (2009)Google Scholar
  8. 8.
    Pavithra, A.G., Menesha Karan, D., Ajith Kumar, D., Anu Shalin, P.S.: Non invasive technique to measure glucose and haemoglobin level in blood using NIR-occlusion spectroscopy. Int. J. Sci. Res. Manag. (IJSRM) 2(4), 756–759 (2013)Google Scholar
  9. 9.
    Kumar, R., Ranganathan, H.: Non invasive sensor technology for total haemoglobin measurement in blood. J. Ind. Intell. Inf. 1(4) (2013)Google Scholar
  10. 10.
    Narkhede, P., Dhalwar, S., Karthikeyan, B.: NIR based non-invasive blood glucose measurement. Indian J. Sci. Technol. 9(41) (2016).  https://doi.org/10.17485/ijst/2016/v9i41/98996
  11. 11.
    Haxha, S., Jhoja, J.: Optical based noninvasive glucose monitoring sensor prototype. IEEE Photonics J. 8(6), 1–11 (2016)CrossRefGoogle Scholar
  12. 12.
    Ali, H., Bensaali, F., Jaber, F.: Novel approach to non-invasive blood glucose monitoring based on transmittance and refraction of visible laser light. IEEE Access (2017)Google Scholar

Copyright information

© Springer Nature Switzerland AG 2020

Authors and Affiliations

  • S. Selva Nidhyananthan
  • R. Dharshana Shahini
    • 1
    Email author
  • S. Hari Priya
    • 1
  1. 1.Mepco Schlenk Engineering CollegeSivakasiIndia

Personalised recommendations