Abstract
The workers’ safety and wellbeing is the key to achieve higher levels of productivity and efficiency. An adequate lighting is one of the factors that influences the workplace and consequently, the comfort and satisfaction of the workers. This study aims to assess the lighting quality at seven work sections in a granite company. Three illuminance measurements were done with a luximeter, one with natural light and two at nightfall (with and without shadows). By studying their illuminance and luminance levels, it was perceivable the existence of lighting problems in all workplaces studied. Proven the inefficient lightning system, two experiments were run for the six workplaces. To the seventh section, as it is different from the others, a different approach was used. The results showed that with an implementation of roller shutters, 14 luminaires were enough to guarantee the necessary illuminance level. Without Dundee Roller Shutters, the number of luminaires needed was 15. To the seventh section it is recommended the utilization of a local lamp. The importance of lighting conditions is discussed, and the results obtained from illuminance measurements are presented so that improvements in the production area can be implemented.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Juslén, H., Tenner, A.: Mechanisms involved in enhancing human performance by changing the lighting in the industrial workplace. Int. J. Ind. Ergon. 35(9), 843–855 (2005). https://doi.org/10.1016/j.ergon.2005.03.002
Dianat, I., Vahedi, A., Dehnavi, S.: Association between objective and subjective assessments of environmental ergonomic factors in manufacturing plants. Int. J.Ind. Ergon. 54, 26–31 (2016). https://doi.org/10.1016/j.ergon.2015.12.004
Bellia, L., Bisegna, F., Spada, G.: Lighting in indoor environments: visual and non-visual effects of light sources with different spectral power distributions. Build. Environ. 46(10), 1984–1992 (2011). https://doi.org/10.1016/j.buildenv.2011.04.007
Smolders, K.C.H.J., De Kort, Y.A.W., Cluitmans, P.J.M.: Physiology & behavior a higher illuminance induces alertness even during office hours: findings on subjective measures, task performance and heart rate measures. Physiol. Behav. 107(1), 7–16 (2012). https://doi.org/10.1016/j.physbeh.2012.04.028
Ganslandt, R., Hofmann, H.: Handbook of Lighting Design. (ERCO Edition, Ed.) 1st edn. Lüdenscheid: Verlag Vieweg, (1992)
Khorasanizadeh, H., Parkkinen, J., Parthiban, R., Moore, J.D.: Energy and economic benefits of LED adoption in Malaysia. Renew. Sust. Energy Rev. 49, 629–637 (2015). https://doi.org/10.1016/j.rser.2015.04.112
Araújo, LP de.: Projecto-de-iluminação-interior-1
Acknowledgements
This work has been supported by FCT—Fundação para a Ciência e Tecnologia within the Project Scope: UID/CEC/00319/2019.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Torres, A. et al. (2019). Lighting Assessment at Workplaces in a Granite Manufacturing Company. In: Arezes, P., et al. Occupational and Environmental Safety and Health. Studies in Systems, Decision and Control, vol 202. Springer, Cham. https://doi.org/10.1007/978-3-030-14730-3_57
Download citation
DOI: https://doi.org/10.1007/978-3-030-14730-3_57
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-14729-7
Online ISBN: 978-3-030-14730-3
eBook Packages: EngineeringEngineering (R0)