Implementation of Tower Grounding Resistance Measurement Based on Decreasing Overhead Grounding Line’s Current Shunt Using High-Frequency Power Supply

  • Yujie PeiEmail author
  • Jinglong Mu
  • Weijun Li
  • Jun Dong
  • Jianguo Xu
  • Chunmei Guan
  • Yi Qu
  • Hongchuang Ma
Conference paper
Part of the Advances in Intelligent Systems and Computing book series (AISC, volume 921)

Abstract

This paper analyses the production of the current shunt and the influence factor. Then establish the tower overhead ground wire current shunt model. The current commonly used grounding resistance measurement method for shaking table method and clamp meter, shaking table method need to disconnect the ground lead line, the measuring error of clamp meter, based on the two methods proposed a new method of grounding measurement, continuous grounding the premise the high frequency power supply to achieve the measurement of grounding resistance. According to the model, this paper explained the relationship between the injecting current shunt coefficient and the overhead ground wire and voltage frequency when testing the grounding resistance. As a key to frequency characteristics of overhead ground wire, we offered a new method of measuring tower grounding resistance called high-frequency power method and got the best injection current frequency by tower split calculate. Compared with the shaking table method, the clamp table method is the most error, and the randomness of measured data is very strong. Followed by different frequency power measurement, the measuring result of the high-frequency power supply is close to that of the shake table method, and the error is less than 10%.

Keywords

Frequency Current shunt High-frequency power method 

References

  1. 1.
    Liu, Z., Xu, J.: Comparison of several kinds of the instrument for measuring grounding resistance of tower. High Volt. Eng. 27(5), 76–77 (2001)Google Scholar
  2. 2.
    Ye, T.F.: Research and development for the measurement system of large grounding impedance based on the shunt function of overhead lightning conductor. North China Electri. Power Univ. Wuhan (2012)Google Scholar
  3. 3.
    Liu, W., Liu, Y., Liu, H.T.: Grounding resistance measurement error analysis for grounding device and overhead grounding line connection not disconnected. Insul. Surge Arresters 4(2), 62–65 (2012)Google Scholar
  4. 4.
    Dawalibi, F.: Ground fault current distribution between soil and neutral conductors. IEEE Trans on Power Apparatus and Systems 99(2), 452–461 (1980)CrossRefGoogle Scholar
  5. 5.
    Niles, G.B.: Measurements and computations of fault current distribution on overhead transmission lines. IEEE Trans. Power Apparatus Syst. 103(3), 553–560 (1984)Google Scholar
  6. 6.
    Zou, J.F.: Computation of fault current distribution and shielding coefficients of ground wires for overhead transmission lines. Power Syst. Technol. 24(10), 27–30 (2000)Google Scholar
  7. 7.
    Zhao, B., Li, L., Cui, X.: Shunt currents computation of ground lines in power circuits. J. North China Electr. Power Univ. 29(4), 5–7 (2002)Google Scholar
  8. 8.
    Zhang, Q.: New technology of surveying the pole lapping earth resistance based on the high-frequency parallel method and its equipment. High Volt. Eng. 33(1), 194–195 (2007)Google Scholar
  9. 9.
    Li, D.J., Wang, W., Zhang, Y.: A new analysis approach on the coefficient of lightning shield line when the earth short circuit taking place in substation. Insul. Surge Arresters 8(1), 48–51 (2014)Google Scholar

Copyright information

© Springer Nature Switzerland AG 2020

Authors and Affiliations

  • Yujie Pei
    • 1
    Email author
  • Jinglong Mu
    • 1
  • Weijun Li
    • 1
  • Jun Dong
    • 1
  • Jianguo Xu
    • 1
  • Chunmei Guan
    • 1
  • Yi Qu
    • 1
  • Hongchuang Ma
    • 1
  1. 1.Fushun Power Supply BranchState Grid Liaoning Electric Power Supply Co., Ltd.FushunChina

Personalised recommendations