Acoustic Emission Testing and Evaluation of Ethylene Horizontal Tank
Conference paper
First Online:
- 266 Downloads
Abstract
Acoustic emission (AE) technique was applied to detect four ethylene tanks in a chemical plant. Based on the testing data, the AE sources were located and synthetically graded. Then the conventional testing methods were used to reinspect the acoustic emission sources. The reinspected results indicate that two cracks near the saddle are unaccepted and the others are faultless. The AE test results have good consistency with the reinspection results.
Key words
Ethylene Horizontal tank Acoustic emission testing Location Penetrant testingReferences
- 1.S. Gongtian, L. Bangxian, D. Qingru, Metal pressure vessel AE monitoring and safety assessment. Boil Pres. Ves. Saf. Chin. 14(4), 37–39 (1998)Google Scholar
- 2.TSG7001-2013, Periodic Inspection Rules for Pressure Vessels Google Scholar
- 3.JB/T 47013.9-2012, Periodic Inspection Rules for Pressure Vessels Google Scholar