Advertisement

Texture Analysis on Thyroid Ultrasound Images for the Classification of Hashimoto Thyroiditis

  • S. KohilaEmail author
  • G. Sankara Malliga
Conference paper
Part of the Lecture Notes in Computational Vision and Biomechanics book series (LNCVB, volume 31)

Abstract

The biopsy using Fine Needle Aspiration (FNA) is a major procedure/testing method which has been regularly recommended, at a time, exactly when a thyroid nodule is suspected or else identified. The FNA will usually reveal if a nodule is benign or malignant. Histopathology is also sometimes recommended. Another regular test is the ultrasound. Yet, the ultrasound cannot recognize or distinguish the thyroid disorders. Hashimoto thyroiditis is the most widely recognized kind of inflammation of the thyroid gland. The motto of this work is to identify the Hashimoto’s thyroiditis disorder using only ultrasonogram images without going for any painful examination. In this paper, features are studied using the Neighborhood Gray Tone Difference Matrix (NGTDM), Statistical Feature Matrix (SFM), and Laws’ texture energy measures methods. The salient features from the above procedures are helpful to identify and in separating the two types of ultrasonic thyroid images as normal and Hashimoto’s thyroiditis. The student two-tailed unpaired T-test method is employed to classify the two groups. A major difference between the two groups (p < 0.001) was observed. The results are correlated with the histopathology results. The results prove that the Hashimoto thyroiditis can be identified using the ultrasound images.

Keywords

Texture analysis T-test Hashimoto thyroiditis NGTDM SFM Laws’ texture energy measures Thyroiditis 

References

  1. 1.
    Acharya UR, VinithaSree S, Mookiah MRK, Yantri R, Molinari F, Zieleźnik W, Małyszek-Tumidajewicz J, Stępień B, Bardales RH, Witkowska A, Suri JS (2013) Diagnosis of Hashimoto’s thyroiditis in ultrasound using tissue characterization and pixel classification. Proc Inst Mech Eng [H] 227(7):788–798CrossRefGoogle Scholar
  2. 2.
    Chang CY, Chen SJ, Tsai MF (2010) Application of support-vector-machine-based method for feature selection and classification of thyroid nodules in ultra sound images. Pattern Recogn 43(10):3494–3506CrossRefGoogle Scholar
  3. 3.
    Haralick RM, Shanmugam K (1973) Textural features for image classification. IEEE Trans Syst Man Cybern 6:610–621CrossRefGoogle Scholar
  4. 4.
    Tomimori EK, Camargo RY, Bisi H, Medeiros-Neto G (1999) Combined ultrasonographic and cytological studies in the diagnosis of thyroid nodules. Biochimie 81(5):447–452CrossRefGoogle Scholar
  5. 5.
    Maroulis DE, Savelonas MA, Iakovidis DK, Karkanis SA, Dimitropoulos N (2007) Variable background active contour model for computer-aided delineation of nodules in thyroid ultrasound images. IEEE Trans Inf Technol Biomed 11(5):537–543CrossRefGoogle Scholar
  6. 6.
    Kousarrizi MN, Seiti F, Teshnehlab M (2012) An experimental comparative study on thyroid disease diagnosis based on feature subset selection and classifiion. Int J Electr Comput Sci IJECS-IJENS 12(01):13–20Google Scholar
  7. 7.
    Tsantis S, Dimitropoulos N, Cavouras D, Nikiforidis G (2009) Morphological and wavelet features towards sonographic thyroid nodules evalution. Comput Med Imag Graph 33(2):91–99CrossRefGoogle Scholar
  8. 8.
    Kohila S, Malliga GS (2016) Classification of the thyroiditis based on characteristic sonographic textural features and correlated histopathology results. In: IEEE international conference on signal and image processing (ICSIP). IEEE, pp 305–309Google Scholar
  9. 9.
    Amadasun M, King R (1989) Textural features corresponding to textural properties. IEEE Trans Syst Man Cybern 19(5):1264–1274CrossRefGoogle Scholar
  10. 10.
    Wu CM, Chen YC (1992) Statistical feature matrix for texture analysis. CVGIP: Graph Models Image Process 54(5):407–419Google Scholar
  11. 11.
    Chang CY, Tsai MF, Chen SJ (2008) Classification of the thyroid nodules using support vector machines. In: 2008 IEEE international joint conference on neural networks, IJCNN 2008. (IEEE world congress on computational intelligence). IEEE, pp 3093–3098Google Scholar
  12. 12.
    Laws KI (1979) Texture energy measures. In: Proceedings of a workshop on Image understanding workshop, pp 47–51Google Scholar
  13. 13.
    Wu CM, Chen YC, Hsieh KS (1992) Texture features for classification of ultrasonic liver images. IEEE Trans Med Imaging 11(2):141–152CrossRefGoogle Scholar
  14. 14.
    Sapthagirivasan V, Anburajan M (2013) Diagnosis of osteoporosis by extraction of trabecular features from hip radiographs using support vector machine: an investigation panorama with DXA. Comput Biol Med 43(11):1910–1919CrossRefGoogle Scholar