Advertisement

Wearable Sensory Apparatus Performance While Using Inertial Measurement Units

  • Grega Logar
  • Zoran Ivanic
  • Marko Munih
Conference paper
Part of the Biosystems & Biorobotics book series (BIOSYSROB, volume 22)

Abstract

With the objective of satisfying the technical and functional requirements set for intention detection (ID) algorithm, we investigated suitable strategies to reduce the number of remote units such as inertial measurement units (IMU). The optimization should not affect the ID algorithm, which needs to detect continuous transitions between different locomotion modes such as ground-level walking, walking up and down slopes, climbing/descending stairs, standing up, sitting down, turning and other scenarios of real life. In the developed solution, the number of remote units was reduced from 9 to 4. In order to achieve the same level of ID algorithm performance, the WSA units need to perform almost perfectly. The main innovation is nearly perfect data transfer from remote units to the master unit. This way a package loss below 0.05% of transferred packages is achieved.

References

  1. 1.
    Lambrecht, B.G., Kazerooni, H.: Design of a semi-active knee prosthesis. In: Proceedings of the IEEE International Conference on Robotics and Automation, Kobe, Japan, pp. 639–645 (2009)Google Scholar
  2. 2.
    Martinez-Villalpando, E.C., Herr, H.: Agonist-antagonist active knee prosthesis: a preliminary study in level-ground walking. J. Rehabil. Res. Dev. 46(3), 361 (2009)CrossRefGoogle Scholar
  3. 3.
    Au, S.K., Weber, J., Herr, H.: Powered ankle-foot prosthesis improves walking metabolic economy. IEEE Trans. Robot. 25(1), 51–66 (2009)CrossRefGoogle Scholar
  4. 4.
    Pillai, M.V., Kazerooni, H., Hurwich, A.: Design of a semi-active knee-ankle prosthesis. In: Proceedings of the 2011 IEEE International Conference on Robotics and Automation, Shanghai, China, pp. 5293–5300 (2011)Google Scholar
  5. 5.
    Ambrozic, L.: CYBERLEGs: a user-oriented robotic transfemoral prosthesis with whole-body awareness control. IEEE Robot. Autom. Mag. 21(4), 82–93 (2014)CrossRefGoogle Scholar
  6. 6.
    Goršič, M.: Online phase detection using wearable sensors for walking with a robotic prosthesis. Sensors 14(2), 2776–2794 (2014)CrossRefGoogle Scholar
  7. 7.
    Parri, A.: Whole body awareness for controlling a robotic transfemoral prosthesis. Front. Neurorobotics 11, 25 (2017)CrossRefGoogle Scholar

Copyright information

© Springer Nature Switzerland AG 2019

Authors and Affiliations

  1. 1.Faculty of Electrical Engineering, University of LjubljanaLjubljanaSlovenia

Personalised recommendations