Abstract
Gas temperature is of great importance for assessment of heat exposure to tunnel users and tunnel structures, estimation of fire detection time and possibility of fire spread, and to design ventilation systems. In this chapter, the theory of fire plumes in ventilated flows is presented with a focus on the maximum ceiling gas temperature and its position in tunnel fires. The maximum ceiling excess gas temperature can be classified into two regions, depending on the ventilation velocity. Each can be divided into two subregions. The first subregion exhibits a linear increase which transits into a constant period, depending on the fire size, ventilation, and effective tunnel height. The position of the maximum ceiling gas temperature is directly related to a dimensionless ventilation velocity. A theoretical analysis of the upper smoke layer is presented and correlations for the distribution of ceiling gas temperature along the tunnel are given to support this analysis. Finally, a one-dimensional model of average gas temperatures in tunnel fires with longitudinal ventilation is presented.
Keywords
Ventilation flow Fire plume Maximum ceiling gas temperature Position Flame angle Temperature distribution One-dimensional modelReferences
- 1.Carvel RO, Marlair G (2005) A history of fire incidents in tunnels. In: Beard AN, Carvel RO (eds) The Handbook of Tunnel Fire Safety. Thomas Telford Publishing, London, UK, pp 3–41Google Scholar
- 2.Fire-resistance tests—Elements of building construction—Part 1: General requirements (1999). First edn. International Organization for Standardization,Google Scholar
- 3.Fire resistance tests—Part 2: Alternative and additional procedures (1999). First edn. European Committee for Standardization, EN 1363-2Google Scholar
- 4.Beproeving van het gedrag bij verhitting van twee isolatiematerialen ter bescherming van tunnels bij brand (1979). Instituut TNO voor Bouwmaterialen en Bouwconstructies, Delft, The NetherlandsGoogle Scholar
- 5.Richtlinien für Ausstattung und Betrieb von Tunneln (RABT) (1985). Ausgabe 1985 edn. Forschungsgesellschaft für Straßen- und VerkehrswesenGoogle Scholar
- 6.Abschlussbericht zum BMVBS/ BASt Forschungsvorhaben 15.0391/2003/ERB: Brandschutzverhalten von selbstverdich-tendem Beton (SVB) im Straßentunnelbau (2005). MFPA Leipzig, MärzGoogle Scholar
- 7.Hoult DP, Fay JA, Forney LJ (1969) A Theory of Plume Rise Compared with Field Observations. Journal of the Air Pollution Control Association 19:585–590Google Scholar
- 8.Hoult DP, C. WJ (1972) Turbulent plume in a laminar cross flow. Atmospheric Environment 6 (8):513–530Google Scholar
- 9.Kurioka H, Oka Y, Satoh H, Sugawa O (2003) Fire properties in near field of square fire source with longitudinal ventilation in tunnels. Fire Safety Journal 38:319–340Google Scholar
- 10.Li YZ, Lei B, Ingason H (2011) The maximum temperature of buoyancy-driven smoke flow beneath the ceiling in tunnel fires. Fire Safety Journal 46 (4):204–210Google Scholar
- 11.Li YZ, Ingason H (2012) The maximum ceiling gas temperature in a large tunnel fire. Fire Safety Journal 48:38–48Google Scholar
- 12.Li YZ, Ingason H (2010) Maximum Temperature beneath Ceiling in a Tunnel Fire. SP Report 2010:51, SP Technical Research Institute of Sweden, Borås, SwedenGoogle Scholar
- 13.Karlsson B, Quintier JG (2000) Enclosure Fire Dynamics. CRC Press, New YorkGoogle Scholar
- 14.Heskestad G (2008) Fire Plumes, Flame Height, and Air Entrainment. In: DiNenno PJ, Drysdale D, Beyler CL et al. (eds) The SFPE Handbook of Fire Protection Engineering. Fourth Edition edn. National Fire Protection Association, Quincy, MA, USA, pp 2–1–2–20Google Scholar
- 15.Zukoski EE Smoke movement and mixing in two-layer fire models. In: The 8th UJNR Joint Panel Meeting on Fire Research and Safety, Tsukuba, 13–17 June 1985.Google Scholar
- 16.Quintiere JG, J. RW, W JW (1981) The effect of room openings on fire plume entrainment. Combustion Science and Technology 26:193–201Google Scholar
- 17.Raj P. P. K., Moussa A. N., K A (1981) Experiments involving pool and vapor fires from spills of liquidified natural gas on water. Prepared for U.S. Dept. of Transportation, U.S. Coast Guard, Rept. No. CG-D-55–79.Google Scholar
- 18.McCaffrey BJ (1979) Purely Buoyant Diffusion Flames: Some Experimental Results. NBSIR 79-1910. National Bureau of Standards, Washington, D.C., USAGoogle Scholar
- 19.Ingason H, Lönnermark A, Li YZ (2011) Runehamar Tunnel Fire Tests. SP Technicial Research Institute, SP Report 2011:55 Borås, SwedenGoogle Scholar
- 20.Memorial Tunnel Fire Ventilation Test Program—Test Report (1995). Massachusetts Highway Department and Federal Highway Administration, MassachusettsGoogle Scholar
- 21.Li YZ, Ingason H (2014) Position of Maximum Ceiling Temperature in a Tunnel Fire. Fire Technology 50:889–905Google Scholar
- 22.Li YZ, Lei B, Ingason H (2010) Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires. Fire Safety Journal 45:361–370Google Scholar
- 23.Ingason H, Li YZ (2010) Model scale tunnel fire tests with longitudinal ventilation. Fire Safety Journal 45:371–384Google Scholar