Handbook of Biological Confocal Microscopy pp 525-534 | Cite as
Comparison of Various Optical Sectioning Methods
The Scanning Slit Confocal Microscope
Chapter
Abstract
The term confocal microscopy has been applied primarily to instruments using circular field stops (e.g., single pinholes or arrays of pinholes in the illumination and imaging systems). Other aperture shapes can of course be utilized, and the slit is an attractive alternative. In a number of circumstances, the slit aperture confocal system can have advantages over circular aperture systems.
Keywords
Focal Plane Optical Section Stray Light Central Divider Confocal System
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
Preview
Unable to display preview. Download preview PDF.
References
- Agard, D., and Sedat, J.W., 1983, Three dimensional architecture of a polytene nucleus, Nature 302:676–681.PubMedCrossRefGoogle Scholar
- Agard, D.A., 1984, Optical sectioning microscopy: Cellular architecture in three dimensions, Annu. Rev. Biophys. Bioeng. 13:191–219.PubMedCrossRefGoogle Scholar
- Baer, S.C., 1970, Focal plane specific microscopy, U.S. Patent No. 3,547,512.Google Scholar
- Baer, S.C., 1989, Tandem scanning slit microscope, Proc. SPIE 1139:99–101.CrossRefGoogle Scholar
- Brakenhoff, G.J., and Visscher, K., 1993, Imaging modes for bilateral confocal scanning microscopy, J. Microsc. 171:17–26.CrossRefGoogle Scholar
- Brown, M., 1969, Slit image photography, Trans. Ophthalmol. Soc UK 89:397.Google Scholar
- Campbell, C.J., Koester, C.J., Rittler, M.C., and Tackaberry, R.B., 1974, Physiological Optics, Harper & Row, Hagerstown, Maryland, p. 179.Google Scholar
- Fay, F.S., Fogarty, K.E., and Coggins, J.M., 1985, Analysis of molecular distribution in single cells using a digital imaging microscope. In: Optical Methods in Cell Physiology (P. DeWeer and B.M. Salzberg, eds.), Wiley, New York, pp. 51–62.Google Scholar
- Gallagher, B., and Maurice, D., 1977, Striations of light scattering in the corneal stroma, J. Ultrastruct. Res. 61:100–114.PubMedCrossRefGoogle Scholar
- Gruenbaum, Y., Hochstrasser, M., Mathog, D., Saumweber, H., Agard, D.A., and Sedat, J.W., 1984, Spatial organization of the Drosophila nucleus: A three-dimensional cytogenic study, J. Cell Sci. Suppl. 1:223–234.PubMedGoogle Scholar
- Hochwin, O., Ahrend, M.H.J., and Bours, J., 1986, Correlation of Scheimpflug photography of the anterior eye segment with biochemical analysis of the lens, Graefes. Arch. Clin. Exp. Ophthalmol. 224:265.CrossRefGoogle Scholar
- Inoué, S., 1986, Video Microscopy, Plenum Press, New York, p. 410.Google Scholar
- Khanna, S.M., Koester, C.J., and van Netten, S.M., 1989, Integration of the optical sectioning microscope and heterodyne interferometer for vibration measurement. Acta Otolaryngol. (Suppl.) 467:43–49.CrossRefGoogle Scholar
- Kingslake, R., 1983, Optical System Design, Academic Press, London, pp. 260–261.Google Scholar
- Koester, C.J., 1980, A scanning mirror microscope with optical sectioning characteristics: Applications in ophthalmology, Appl. Optics 19:1749–1757.CrossRefGoogle Scholar
- Koester, C.J., 1990, High efficiency optical sectioning with confocal slits, Trans. Roy. Microsc. Soc. 1:327–332.Google Scholar
- Koester, C.J., Auran, J.D., Rosskothen, H.D., Florakis, G.J., and Tackaberry, R.B., 1993, Clinical microscopy of the cornea utilizing optical sectioning and a high-numerical-aperture objective, J. Opt. Soc. Am. A 10:1670–1679.PubMedCrossRefGoogle Scholar
- Koester, C.J., Khanna, S.M., Rosskothen, H.D., Tackaberry, R.B., and Ulfendahl, M., 1994, Confocal slit, divided aperture microscope: Applications in ear research, Appl. Optics 33:702–708.CrossRefGoogle Scholar
- Maurice, D.M., 1968, Cellular membrane activity in the corneal endothelium of the intact eye, Experientia 15:1094–1095.CrossRefGoogle Scholar
- Masters, B.M., Thaer, A.A., and Hund, H., 1993, Confocal microscopy of the human in vivo cornea. In: Ophthalmic and Visual Optics/Noninvasive Assessment of the Visual System Technical Digest, Vol. 3, Optical Society of America, Washington, D.C., pp. 133–136.Google Scholar
- Maurice, D.M., 1974, A scanning slit microscope, Invest. Ophthalmol. 13:1033–1037.PubMedGoogle Scholar
- Minsky, M., 1961, Microscopy apparatus, U.S. Patent No. 3,013,467.Google Scholar
- Nomarski, G., 1955, Microinterféromètre différentiel à ondes polarisées, J. Phys. Radium 16:S9–S13.Google Scholar
- Petráň M., Hadravsky, M., Egger, M.D., and Galambos, R., 1968, Tandem scanning reflected light microscope, J. Opt. Soc. Am. 58:661–664.CrossRefGoogle Scholar
- Webb, R.H., Hughes, G.W., and Delori, F.C., 1987, Confocal laser scanning ophthalmoscope, Appl. Optics 26:1492–1499.CrossRefGoogle Scholar
- Wilson, T., and Sheppard, C., 1984, Theory and Practice of Scanning Optical Microscopy, Academic Press, London, p. 72.Google Scholar
- Zeimer, R.C., Mori, M.T., and Khoobehi, B., 1989, Feasibility test of a new method to measure retinal thickness noninvasively, Invest. Ophthalmol. Vis. Sci. 30:2099–2105.PubMedGoogle Scholar
Copyright information
© Springer Science+Business Media New York 1995