Abstract
Although infrequent, dislodgement of foreign bodies is a possibility during percutaneous dialysis access intervention. Depending upon its location, a foreign body can have an insignificant impact or lead to serious consequences. Therefore, timely recognition of this complication and its management is of utmost importance during percutaneous interventions. This chapter provides practical information on strategies to address dislodged foreign bodies.
Keywords
Foreign Body Guide Wire Diagnostic Catheter Dialysis Access Foreign Body Removal
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
References
- 1.Thomas J, Sinclair-Smith B, Bloomfield D, Davachi A. Non-surgical retrieval of a broken segment of steel spring guide from right atrium and inferior vena cava. Circulation. 1964;30:106–8.PubMedCrossRefGoogle Scholar
- 2.Uflacker R, Lima S, Melichar AC. Intravascular foreign bodies: percutaneous retrieval. Radiology. 1986;160:731–5.PubMedGoogle Scholar
- 3.Egglin TK, Dickey KW, Rosenblatt M, Pollak JS. Retrieval of intravascular foreign bodies: experience in 32 cases. AJR Am J Roentgenol. 1995;164:1259–64.PubMedCrossRefGoogle Scholar
- 4.Thompson K. Non-surgical retrieval of devices and foreign bodies. Endovasc Today. 2010:29–32.Google Scholar
- 5.Miller SF, McCowan TC, Eidt JF, et al. Embolization of a prosthetic mitral valve leaflet: localization with intravascular US. J Vasc Interv Radiol. 1991;2:375–8.PubMedCrossRefGoogle Scholar
- 6.Bernhardt LC, Wegner GP, Mendenhall JT. Intravenous catheter embolization of the pulmonary artery. Chest. 1970;57:329–32.PubMedCrossRefGoogle Scholar
- 7.Richardson JD, Grover FL, Trinkle JK. Intravenous catheter emboli: experience with 20 cases and collective review. Am J Surg. 1974;128:722–7.PubMedCrossRefGoogle Scholar
- 8.Doering RB, Stemmer EA, Connolly JE. Complications of indwelling venous catheters with particular reference to catheter embolus. Am J Surg. 1967;114:259–66.PubMedCrossRefGoogle Scholar
- 9.Cantor WJ, Lazzam C, Cohen EA, et al. Failed coronary stent deployment. Am Heart J. 1998;136:1088–95.PubMedCrossRefGoogle Scholar
- 10.Druskin MS, Siegel DD. Bacterial contamination of indwelling intravenous polyethylene catheter. JAMA. 1963;185:966–70.PubMedCrossRefGoogle Scholar
- 11.Prahlow JA, Obryant TJ, Barnard JJ. Cardiac perforation due to Wallstent embolization: a fatal complication of the transjugular intrahepatic portosystemic shunt procedure. Radiology. 1997;205:170–2.PubMedGoogle Scholar
- 12.Kozman H, Wiseman AH, Cook JR. Long-term outcome following coronary stent embolization or misdeployment. Am J Cardiol. 2001;88:630–4.PubMedCrossRefGoogle Scholar
- 13.Kammler J, Leisch F, Kerschner K, et al. Long-term follow-up in patients with last coronary stents during interventional procedures. Am J Cardiol. 2006;98:367–9.PubMedCrossRefGoogle Scholar
- 14.Dotter CT, Roesch J, Bilbao MK. Transluminal extraction of catheter and guide fragments from the heart and great vessels: 29 collected cases. AJR Am J Roentgenol. 1971;111:467–72.CrossRefGoogle Scholar
- 15.Curry JL. Recovery of detached intravascular catheter or guide wire fragments. A proposed method. AJR Am J Roentgenol. 1969;105:894–6.CrossRefGoogle Scholar
- 16.Dondelinger RF, Lepoutre B, Kurdziel JC. Percutaneous vascular foreign body retrieval: experience of an 11-year period. Eur J Radiol. 1991;12:4–10.PubMedCrossRefGoogle Scholar
- 17.Fischer RG, Ferreyro R. Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies. AJR Am J Roentgenol. 1978;130:541–8.CrossRefGoogle Scholar
- 18.Slonim SM, Dake MD, Razavi MK, et al. Management of misplaced or migrated endovascular stents. J Vasc Interv Radiol. 1999;10:851–9.PubMedCrossRefGoogle Scholar
- 19.Yedlicka Jr JW, Carson JE, Hunter DW, et al. Nitinol gooseneck snare for removal of foreign bodies: experimental study and clinical evaluation. Radiology. 1991;178:691–3.PubMedGoogle Scholar
- 20.Cekirge S, Weiss JP, Foster RG, et al. Percutaneous retrieval of foreign bodies: experience with the nitinol goose neck snare. J Vasc Interv Radiol. 1993;4:805–10.PubMedCrossRefGoogle Scholar
- 21.Lassers BW, Pickering D. Removal of an iatrogenic foreign body from the aorta by means of a ureteric stone catcher. Am Heart J. 1967;73(3):375–8.PubMedCrossRefGoogle Scholar
- 22.Trerotola S. Textbook of vascular interventional radiology with clinical perspectives. 2nd Ed. Thieme Publishing Group, 2000. p. 612–20.Google Scholar
- 23.Beathard G. ASDIN Core Curriculum for Interventional Nephrology. 13th Ed. ASDIN (American Society of Diagnostic Interventional Nephrology). p. 53–5.Google Scholar
- 24.Gabelmann A, Krämer S, Görich J. Percutaneous retrieval of lost or misplaced intravascular objects. AJR Am J Roentgenol. 2001;176:1509–13.PubMedCrossRefGoogle Scholar
- 25.Hartnell GG, Jordan SJ. Percutaneous removal of a misplaced Palmaz stent with a coaxial snare technique. J Vasc Interv Radiol. 1995;6:799–801.PubMedCrossRefGoogle Scholar
- 26.Greenfield LJ, Crute SL. Retrieval of the Greenfield vena caval filter. Surgery. 1980;88:719–22.PubMedGoogle Scholar
- 27.Sanchez RB, Roberts AC, Valji K, et al. Wallstent misplacement during transjugular placement of an intrahepatic portosystemic shunt: retrieval with a loop snare. AJR Am J Roentgenol. 1992;159:129–30.PubMedCrossRefGoogle Scholar
- 28.Gabelmann A, Krämer SC, Tomczak R, Görich J. Percutaneous technique for managing maldeployed or migrated stents. J Endovasc Ther. 2001;8:291–302.PubMedCrossRefGoogle Scholar
- 29.Savage C, Ozkan OS, Walser EM, et al. Percutaneous retrieval of chronic intravascular foreign bodies. Cardiovasc Intervent Radiol. 2003;26:440–2.PubMedGoogle Scholar
Copyright information
© Springer Science+Business Media New York 2014