Case 3: Broviac Catheter Placement in a Neonatal Intensive Care Unit

  • John G. Brock-Utne
Chapter

Abstract

A 43-day-old (1.3-kg) girl born at 27 weeks is scheduled for a Broviac catheter replacement in the neonatal intensive care unit (NICU). She is in the NICU because of respiratory failure, bronchopulmonary dysplasia, right lower lobe pneumonia, and sepsis. She has failed extubation twice in the past due to postextubation stridor and desaturation. The day before surgery, the patient was intubated with a 2.5 endotracheal tube (ETT) by the NICU staff and ventilated for 12 h before surgery. A large leak has been suspected around the endotracheal tube (ETT), as the nurse has noted hearing the patient cough and cry. At present, the ventilator is working and the settings include an FIO2 of 30 %, respiratory rate of 14, and the pressure setting of 24/5. The patient’s vital signs include a respiratory rate of 60, heart rate of 150 bpm, and oxygen saturation by pulse oximetry of 92–95 %. Her gastric tube is in place and open to air. Coarse breath sounds are heard bilaterally without evidence of leakage around the ETT. Standard monitoring devices are placed except for an end-tidal CO2 monitor, which is not available. A preoperative radiography of the chest had been taken earlier in the morning but is unavailable for viewing.

Keywords

Endotracheal Tube Neonatal Intensive Care Unit Pulse Oximetry Bronchopulmonary Dysplasia Gastric Distension 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Reference

  1. 1.
    Crockett DE, Tays R, Brock-Utne JG. Twelve hours of gastric ventilation. A recipe for disaster (a suggested remedy). Paediatr Anaesth. 1998;8:171–3.PubMedCrossRefGoogle Scholar

Suggested Reading

  1. Anderson K, Schultz-Labahn T. Oesophageal intubation can be undetected by auscultation of the chest. Acta Anaesthesiol Scand. 1994;38:580–2.CrossRefGoogle Scholar
  2. Bhende MS, Thompson AE, Cook DR, Saville AL. Validity of a disposable end-tidal CO, detector in verifying ETT placement in infants and children. Ann Emerg Med. 1992;21:142–5.PubMedCrossRefGoogle Scholar
  3. Bhende MS, Thompson AE, Orr RA. Utility of an end-tidal carbon dioxide detector during stabilization and transport of critically ill children. Pediatrics. 1992;89:1042–4.PubMedGoogle Scholar
  4. Holland R, Webb RK, Runciman WB. The Australian incident monitoring study. System failure: an analysis of 2000 incident reports. Anaesth Intensive Care. 1993;21:684–95.PubMedGoogle Scholar
  5. Unseld H. Unrecognized esophageal intubation. Consideration of prevention in a case. Anaesthesist. 1988;37:198–201.PubMedGoogle Scholar

Copyright information

© Springer Science+Business Media New York 2013

Authors and Affiliations

  • John G. Brock-Utne
    • 1
  1. 1.Department of AnesthesiaStanford UniversityStanfordUSA

Personalised recommendations