Cryogenic instrumentation is becoming more common in the hospital environment. Led by MRI magnets, cryocoolers as well as large amounts of liquid helium and liquid nitrogen are being used in both mobile and fixed installations. Liquid helium is also necessary in the use of SQUID instrumentation. Different methods of attaining low temperatures are compared as to their technical advantages and disadvantages, cost and reliability. Possible new high temperature superconductors would have a considerable impact on dewar systems as well as on changing the emphasis of cryogenic refrigerators and liquid cryogens to temperatures associated with liquid neon, nitrogen or even freon.
Keywords
Liquid Helium Pickup Coil Liquid Cryogen Cold Head Cryogenic EngineerPreview
Unable to display preview. Download preview PDF.
References
- 1.P. A. Bottomley, NMR imaging techniques and applications, Rev. Sci. Instrum. 53 (9): 1319 (1982).CrossRefGoogle Scholar
- 2.T. F. Budinger and P. C. Lauterbur, Nuclear magnetic resonance technology for medical studies, Science, 226:288 (1984),.CrossRefGoogle Scholar
- 3.F. F. Murray, K. F. Hwang and W. D. Markiewicz, Refrigerator operating experience on whole body MRI magnet systems, in: “Advances in Cryogenic Engineering,” Vol. 31, Plenum Press, New York (1986).Google Scholar
- 4.R. C. Longsworth, Interfacing small closed cycle refriderators to liquid helium cryostats, Cryogenics, 24: 175 (1984).CrossRefGoogle Scholar
- 5.R. C. Longsworth, 4 K refrigerator and interface for MRI cryostats, in: “Advances in Cryogenic Engineering,” Vol. 31, Plenum Press, New York (1986).Google Scholar
- 6.G. L. Brownell et al, Positron tomography and nuclear magnetic resonance imaging, Science, 215: 619 (1982).CrossRefGoogle Scholar
- 7.R. Hari et al, Biomagnetism in the study of brain functions, in: “Biomagnetism:Applications and Theory,” H. Weinberg, G. Stroink and T. Katila, eds., Permagon Press, New York, (1985).Google Scholar
- 8.G. M. Brittenham et al, Diagnostic assessment of human iron stores by measurement of hepatic magnetic susceptibility, Il Nuovo Cimento, Vol. 2D, N. 2: 567 (1983).CrossRefGoogle Scholar
- 9.S. J. Williamson and L. Kaufman, Analysis of neuromagnetic signals, in: “Handbook of electroencephalography and clinical neurophysiology,” A. Remond and A. Gevins, eds., Elsevier, Amssterdam, (1986).Google Scholar
- 10.S. Barbanera et al, Use of â superconducting instrumentation for biomagnetic measurements performed in a hospital, IEEE Trans on Mag, Vol. 17, N. 1: 849 (1981).CrossRefGoogle Scholar
- 11.D. Cohen et al, Ferrimagnetic particles in the lung-the relaxation process, IEEE Trans on Biomed Eng, Vol. BME-31, N. 3: 274 (1984).Google Scholar