Scanning Laser Ophthalmoscope

  • Robert H. Webb

Abstract

Ophthalmoscopes are telescopes for viewing the inside of the eye. In effect, this means that the objective lens (or mirror) is of longer focal length than the ocular element which is used to inspect the image formed by the objective. This constraint is then further complicated by the geometry of the eye—a “black body” with a small viewing window covered by a partial reflector. An alternative view might be that the ophthalmoscope is a microscope for which the objective is the eye’s cornea and lens, although that is a better description of a slit lamp.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Rubin ML. The optics of indirect ophthalmoscopy. Surv Ophthalmol 1964;9:449–464.Google Scholar
  2. 2.
    Wilson T, Sheppard CJR. Theory and Practice of Scanning Optical Microscopy. Academic Press, London, 1984. This reference is an important source in the field, but it is a theoretical treatment of considerable mathematical complexity. It ignores scan aberrations, which control most of the decisions when building scanning systems.Google Scholar
  3. 3.
    Mainster MA, Timberlake GT. Webb RH, Hughes GW. Scanning laser ophthalmoscopy: clinical applications. Ophthalmology 1982;89: 852–857.PubMedGoogle Scholar
  4. 4.
    Webb RH, Hughes GW, Pomerantzeff O. Flying spot TV ophthalmoscope. Appl Opt 1980;19:2991–2997.PubMedCrossRefGoogle Scholar
  5. 5.
    Webb RH, Hughes GW. Scanning laser ophthalmoscope. IEEE Transact Biomed Eng 1981;28:488–492.CrossRefGoogle Scholar
  6. 6.
    Webb RH. Optics for laser rasters. Appl Opt 1984;23:3680–3683.PubMedCrossRefGoogle Scholar
  7. 7.
    Webb RH. Manipulating laser light for ophthalmology. IEEE Eng Med Bio Magazine 1985;4:12–16.CrossRefGoogle Scholar
  8. 8.
    Webb RH. How we see the retina. Lasers Ophthalmol (in press).Google Scholar
  9. 9.
    Webb RH, Hughes GW, Delori FC. Confocal scanning laser ophthalmoscope. Appl Opt 1987;26:1492–1499.PubMedCrossRefGoogle Scholar
  10. 10.
    Timberlake GT, Mainster MA, Peli E, et al. Reading with a macular scotoma. Invest Ophthalmol Vis Sci 1986;27:1137–1147.PubMedGoogle Scholar
  11. 11.
    Webb RH. An overview of the scanning laser ophthalmoscope. In Breinin GM, Siegel IM (eds): Advances in Diagnostic Visual Optics. Springer Verlag, New York, 1982, p. 138.Google Scholar
  12. 12.
    Plesch A, Klingbeil U, Bille J. Digital laser scanning fundus camera. Appl Opt 1987;26:1480–1486.PubMedCrossRefGoogle Scholar
  13. 13.
    Timberlake GT, Mainster MA, Webb RH, et al. Retinal localization of scotomata by scanning laser ophthalmoscopy. Invest Ophthalmol Vis Sic 1982;22:91–97.Google Scholar
  14. 14.
    Klingbeil U. Safety aspects of laser scanning ophthalmoscopes. Health Phys 1984;51:81.CrossRefGoogle Scholar
  15. 15.
    Delori FC, Parker JS, Mainster MA. Light levels in fundus photography and fluorescein angiography. Vision Res 1980;20:1099–1104.PubMedCrossRefGoogle Scholar
  16. 16.
    Naseman J, Zrenner E, Kirsch C-M, Kantlehner R. Investigation of retinal occlusive diseases by fluorescence-perfusion-scintigraphy. Invest Ophthalmol Vis Sci 1988;29(suppl):340.Google Scholar
  17. 17.
    Ziemer R. Personal communication.Google Scholar

Copyright information

© Springer-Verlag New York Inc. 1990

Authors and Affiliations

  • Robert H. Webb

There are no affiliations available

Personalised recommendations