Lean in the Cardiac Intensive Care Unit

  • Howard E. Jeffries
  • Jerry J. Zimmerman
  • J. Elaine-Marie Albert
  • Silvia M. Hartmann
Chapter

Abstract

Lean management principles have been used extensively in manufacturing for decades and are increasingly being utilized in healthcare settings over the last 10 years. Lean principles, developed as part of the Toyota Management System, their simultaneous focus on waste reduction and customer satisfaction are vital for healthcare to reach its potential. Lean begins with mapping process flow and then applying lean tools and techniques to optimize the current state, including waste removal, inventory optimization through kanban (signal) systems and standard work. The translation of this manufacturing philosophy to healthcare involves the use of huddles in order to optimize situational awareness and develop clinical standard pathways to ensure that patients with similar pathophysiological abnormalities are treated in a similar fashion.

Keywords

Lean healthcare Process improvement Lean process improvement Clinical standard work 

References

  1. 1.
    Institute for Healthcare Improvement. Going Lean in Health Care. IHI Innovation Series white paper. Cambridge, MA: Institute for Healthcare Improvement; 2005. (Available on www.IHI.org).
  2. 2.
    Holden RJ. Lean thinking in emergency department: a critical review. Ann Emerg Med. 2011;57(3):265–78.PubMedCrossRefGoogle Scholar
  3. 3.
    Hintzen BL, Knoer SJ, Van Dyke CJ, Milavitz BS. Effect of lean process improvement techniques on a university inpatient pharmacy. Am J Health Syst Pharm. 2009;66(22):2042–7.PubMedCrossRefGoogle Scholar
  4. 4.
    Buesa RJ. Adapting lean to histology laboratories. Ann Diagn Pathol. 2009;13(5):322–33.PubMedCrossRefGoogle Scholar
  5. 5.
    Vats A, Goin KH, Villareal MC, Yilmaz T, Fortenberry JD, Keskinocak P. The impact of a lean rounding process in a pediatric intensive care unit. Crit Care Med. 2012;40(2):608–17.PubMedCrossRefGoogle Scholar
  6. 6.
    Mekontso-Dessap A, de Prost N, Girou E, et al. B-type natriuretic peptide and weaning from mechanical ventilation. Intensive Care Med. 2006;32(10):1529–36.PubMedCrossRefGoogle Scholar
  7. 7.
    Chien JY, Lin MS, Huang YC, et al. Changes in B-type natriuretic peptide improve weaning outcome predicted by spontaneous breathing trial. Crit Care Med. 2008;36(5):1421–6.PubMedCrossRefGoogle Scholar
  8. 8.
    Foster CB, Spaeder MC, McCarter RJ, et al. The use of near-infrared spectroscopy during an extubation readiness trial as a predictor of extubation outcome. Pediatr Crit Care Med. 2013;14(6):587–92.PubMedCrossRefGoogle Scholar
  9. 9.
    Quality AfHR. Pocket guide: TeamSTEPPS: US Department of Health and Social Services; 2008.Google Scholar
  10. 10.
    Ohno T. Toyota production system: beyond large-scale production. Portland: Productivity Press; 1988.Google Scholar
  11. 11.
    Newth CJ, Venkataraman S, Willson DF, et al. Weaning and extubation readiness in pediatric patients. Pediatr Crit Care Med. 2009;10(1):1–11.PubMedCentralPubMedCrossRefGoogle Scholar
  12. 12.
    Jouvet PA, Payen V, Gauvin F, et al. Weaning children from mechanical ventilation with a computer-driven protocol: a pilot trial. Intensive Care Med. 2013;39(5):919–25.PubMedCrossRefGoogle Scholar
  13. 13.
    Deeter KH, Zimmerman JJ. Developing and implementing pull systems in the intensive care unit. In: Wellman J, Hagan P, Jeffries H, editors. Leading the lean healthcare journey. New York: CRC Press; 2011. p. 93–108.Google Scholar
  14. 14.
    Jouvet P, Hernert P, Wysocki M. Development and implementation of explicit computerized protocols for mechanical ventilation in children. Ann Intens Care. 2011;1:51.CrossRefGoogle Scholar
  15. 15.
    Lellouche F, Mancebo J, Jolliet P, et al. A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation. Am J Respir Crit Care Med. 2006;174(8):894–900.PubMedCrossRefGoogle Scholar
  16. 16.
    Hermeto F, Bottino MN, Vaillancourt K, et al. Implementation of a respiratory therapist-driven protocol for neonatal ventilation: impact on the premature population. Pediatrics. 2009;123(5):e907–16.PubMedCrossRefGoogle Scholar
  17. 17.
    Khemani RG, Sward K, Morris A, et al. Variability in usual care mechanical ventilation for pediatric acute lung injury: the potential benefit of a lung protective computer protocol. Intensive Care Med. 2011;37(11):1840–8.PubMedCentralPubMedCrossRefGoogle Scholar
  18. 18.
    Burns KE, Meade MO, Lessard MR, et al. Wean earlier and automatically with new technology (the WEAN study). A multicenter, pilot randomized controlled trial. Am J Respir Crit Care Med. 2013;187(11):1203–11.PubMedCrossRefGoogle Scholar
  19. 19.
    Liker JK. Principle 14: becoming a learning organization through relentless reflection (Hansen) and continuous improvement (Kaizen). In: The Toyota way. New York: McGraw-Hill; 2004. p. 250–65.Google Scholar
  20. 20.
    Slutsky AS, Ranieri VM. Ventilator-induced lung injury. N Engl J Med. 2013;369(22):2126–36.PubMedCrossRefGoogle Scholar
  21. 21.
    Jozwiak M, Teboul JL, Anguel N, et al. Beneficial hemodynamic effects of prone positioning in patients with acute respiratory distress syndrome. Am J Respir Crit Care Med. 2013;188(12):1428–33.PubMedCrossRefGoogle Scholar
  22. 22.
    Gattinoni L, Taccone P, Carlesso E, et al. Prone position in acute respiratory distress syndrome. Rationale, indications, and limits. Am J Respir Crit Care Med. 2013;188(11):1286–93.PubMedCrossRefGoogle Scholar
  23. 23.
    Venkatachalam V, Hendley JO, Willson DF. The diagnostic dilemma of ventilator-associated pneumonia in critically ill children. Pediatr Crit Care Med. 2011;12(3):286–96.PubMedCrossRefGoogle Scholar
  24. 24.
    Muszynski JA, Sartori J, Steele L, et al. Multidisciplinary quality improvement initiative to reduce ventilator-associated tracheobronchitis in the PICU. Pediatr Crit Care Med. 2013;14(5):533–8.PubMedCrossRefGoogle Scholar
  25. 25.
    Sarter NB, Woods DD. Situation awareness: a critical but ill defined phenomenon. Int J Aviat Psychol. 1991;1:45–7.CrossRefGoogle Scholar
  26. 26.
    Baker D, Gustafson S, Beaubien J, Salas E, Barach P. Medical teamwork and patient safety: the evidence-based relation. AHRQ Publication No. 05–0053. 2005. Available at: http://www.ahrq.gov/qual/medteam/. Accessed 4 Apr 2014.
  27. 27.
    McGee DC, Gould MK. Preventing complications of central venous catheterization. N Engl J Med. 2003;348:1123–33.PubMedCrossRefGoogle Scholar
  28. 28.
    Merrer J, De Jonghe B, Golliot F, et al. Complications of femoral and subclavian venous catheterization in critically ill patients: a randomized controlled trial. JAMA. 2001;286:700–7.PubMedCrossRefGoogle Scholar

Copyright information

© Springer-Verlag London 2015

Authors and Affiliations

  • Howard E. Jeffries
    • 1
  • Jerry J. Zimmerman
    • 2
  • J. Elaine-Marie Albert
    • 3
  • Silvia M. Hartmann
    • 4
  1. 1.Department of Pediatric Critical CareSeattle Children’s HospitalSeattleUSA
  2. 2.Pediatric Critical Care Medicine, Department of PediatricsSeattle Children’s Hospital, University of Washington School of MedicineSeattleUSA
  3. 3.Pediatric Intensive Care Unit, Department of Pediatric Critical Care MedicineSeattle Children’s HospitalSeattleUSA
  4. 4.Department of Critical Care MedicineSeattle Children’s HospitalSeattleUSA

Personalised recommendations