Optical measurement methods in biomechanics pp 125-153 | Cite as
Optometric methods in biomechanical gait analysis
Abstract
Human movement and its measurement have been of general interest since classical times. Gait analysis is the quantified measurement of movement patterns and forces during walking, which comprise kinematics and kinetics. The actual process of performing such an analysis involves measurement (kinematic and kinetic), storage, retrieval, processing, analysis and presentation. The practical measurement of gait kinematics was not possible until optical technology evolved to facilitate easy and repeatable recording of motion. The kinematic and kinetic measurements allow definition of normal patterns and several key variables have been identified which are thought to characterize gait. This chapter discusses the basics of gait analysis and the progression of the technology.
Keywords
Kinematic Model Gait Analysis Gait Cycle Limb Segment Passive MarkerPreview
Unable to display preview. Download preview PDF.
References
- Angeloni, C., Cappozzo, A., Catani, F. and Leadini, A. (1992) Quantification of relative displacement between bones and skin-and plate-mounted markers, in Proceedings of the Eighth Meeting of the European Society of Biomechanics, p. 279.Google Scholar
- Basmajian, J.V. and De Luca, C.J. (1985) Muscles Alive: Their Functions Revealed by Electromyography. Williams and Wilkins, Baltimore MA.Google Scholar
- Borelli, G.A. (1679) Do Motu Animalium, Rome.Google Scholar
- Cappozzo, A., Della Croce, U., Fioretti, S. et al. (1996) Position and orientation in space of bones during movement — experimental artifacts. Clin. Biomech., 11, 90–100.CrossRefGoogle Scholar
- Chao, E.Y.S. (1980) Justification of tri-axial goniometer for the measurement of joint rotation. J. Biomech., 13, 989–1006.CrossRefGoogle Scholar
- Collins, J.J. (1995) The redundant nature of locomotor optimization laws. J. Biomech., 28, 251–67.CrossRefGoogle Scholar
- Crowninshield, R.D. (1978) Use of optimization techniques to predict muscle forces. J. Biomech. Engng, 100, 88–92.Google Scholar
- Delp, S.L., Loan, J.P., Hoy, M. G. et al. (1990) An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures. IEEE Trans. Bio. Eng., 37, 757–67.CrossRefGoogle Scholar
- Gage, J.R. (1991) Gait Analysis in Cerebral Palsy. McKieth Press, London.Google Scholar
- Gianini, S., Catani, F., Benedetti, M.G. and Leardini, A. (1994) Gait Analysis: Methodologies and Clinical Applications. IOS Press, Amsterdam.Google Scholar
- Gottlieb, G.L. and Agarwal, G.L. (1971) Dynamic relationship between isometric muscle tension and electromyogram in man. J. Appl. Physiol., 30, 345–51.Google Scholar
- Hatze, H. (1977) The complete optimization of a human motion. Math Biosci., 28, 99–135.CrossRefGoogle Scholar
- Inman, V.T. (1947) Functional aspects of the abductor muscles of the hip. J. Bone Jt Surg., 29A, 607–19.Google Scholar
- Inman, V.T. (1966) Human locomotion. Canad. Med. Ass. J., 94, 1047–54.Google Scholar
- Ishida, A. (1993) Description and measurement of anatomical joint motion. Frontiers Med. Biol. Engng, 5, 161–73.Google Scholar
- Jarret, M.A. (1976) A television/computer system for human locomotion analysis. PhD thesis, University of Strathclyde.Google Scholar
- Kadaba, M.P., Ramakrishnan, H.K. and Wootten, M.E. (1990) Measurement of lower extremity kinematics during level walking. J. Orthop. Res., 8, 383–92.CrossRefGoogle Scholar
- Kepple, T.M., Arnold, A.A., Stanhope, S.J. and Siegel, K.L. (1994) Assessment of a method to estimate muscle attachments from surface landmarks: a 3D computer graphics approach. J. Biomech., 27, 365–371.CrossRefGoogle Scholar
- Kim, W., Voloshin, A.S., Johnson, S.N. and Simkin, A. (1993) Measurement of the impulsive bone motion by skin-mounted accelerometers. J. Biomech. Engng, 115, 47–52.Google Scholar
- Marey, E.J. (1895) Movement, Appleton, New York.Google Scholar
- Morris, J.W. (1973) Accelerometry — a technique for the measurement of human body movements. J. Biomech., 6, 729–36.CrossRefGoogle Scholar
- Morrison, J.B. (1968) Bioengineering analysis of force actions transmitted by the knee joint. Bio.-Med. Eng., 90, 164–70.Google Scholar
- Murray, M.P., Drought, A.B. and Kory, R.C. (1964) Walking patterns of normal men. J. Bone Jt Surg., 46A, 335–60.Google Scholar
- Muybridge, E. (1955) The Human Figure in Motion, Dover Publications, New York. Reprint of the original 1901 edition.Google Scholar
- O’Connor, J.J., Shercliff, T., FitzPatrick, D. et al. (1990) Mechanics of the knee, in Knee Ligaments: Structure, Function, Injury, and Repair (eds D.M. Daniel, W.H. Akeson and J.J. O’Connor), Raven Press, New York, Ch. 11.Google Scholar
- Pandy, M.G., Zajac, F.E., Sim, E. and Levine, W.S. (1990) An optimal control model for maximum-height human jumping. J. Biomech., 23, 1185–98.CrossRefGoogle Scholar
- Paul, J.P. (1966) Forces transmitted by joints in the human body. Proc. Inst. Mech. Engr., 181, 8–15.Google Scholar
- Pauwels, F. (1980) Biomechanics of the Locomotor Apparatus. Springer-Verlag, Berlin.Google Scholar
- Seireg, A. and Arvikar, R.J. (1973) A mathematical model for evaluation of forces in lower extremities of the musculo-skeletal system. J. Biomech., 6, 313–26.CrossRefGoogle Scholar
- Sutherland, D.H. and Hagy, J.L. (1972) Measurement of gait movements from motion picture film. J. Bone Jt Surg., 54A, 787–97.Google Scholar
- Sutherland, D.H., Olshen, R.A., Biden, E.N. and Wyatt, M.P. (1988) The Development of Mature Walking, Blackwell, Oxford.Google Scholar
- Thorstensson, A., Nilsson, J., Carlson, H. and Zomlefer, M.R. (1984) Trunk movements in human normal walking. Acta Physiol. Scand., 121, 9–22.CrossRefGoogle Scholar
- Vanderhelm, F.C.T. and Pronk, G.M. (1995) Three-dimensional recording and description of the shoulder mechanism. J. Bio. Eng., 117, 27–40.Google Scholar
- White, S.C., Yack, H.J. and Winter, D.A. (1989) A three-dimensional musculoskeletal model for gait analysis: anatomical variability estimates. J. Biomech., 22, 885–93.CrossRefGoogle Scholar
- Willemsen, A.T.M., Frigo, C. and Boom, H.B.K. (1991) Lower extremity angle measurement with accelerometers — error and sensitivity analysis. IEEE Trans. Bio. Eng., 38, 1186–93.CrossRefGoogle Scholar
- Winter, D.A., Quanbury, A.O., Hobson, D.A. et al. (1974) Kinematics of normal locomotion — a statistical study based on TV data. J. Biomech., 7, 479–86.CrossRefGoogle Scholar
- Woltring, H.J. and Fioretti, S. (1989) Representation and photogrammetric calculation of 3D joint movement. Presented at the First IOC World Congress on Sport Science, Colorado Springs CO.Google Scholar