Interaction Behaviour of the Ultramicroporous Polymer Makrolon ® by Spectroscopic Methods
Abstract
Makrolon
®, a commercially available polycarbonate with a glassy ultramicroporous structure (mean pore-volume 0.1 nm3), was often employed as sensitive layer for optical sensors in recent years. Due to the definite pore volume-distribution, it can be used as a size-selective sensitive layer. The interaction behaviour of Makrolon of different layer-thicknesses under the influence of methanol, ethanol and 1-propanol is characterized by Spectral Ellipsometry (SE), Surface Plasmon Resonance Spectroscopy (SPR) and Reflectometric Interference Spectroscopy (RIfS). Sorption into the polymer layer follows a superposition of Henry- and Langmuir-type behaviour; this was discussed depending on the size of the respective analyte. An adequate layer-thickness for the sensor methods RIfS and SPR is proposed.
Preview
Unable to display preview. Download preview PDF.
References
- 1.Gauglitz G (2005) Anal Bioanal Chem 381:141 CrossRefGoogle Scholar
- 2.Brecht A, Gauglitz G, Kraus G, Nahm W (1993) Sens Actuators B 11:21 CrossRefGoogle Scholar
- 3.Azzam RMA, Bashara NM (1988) Ellipsometry and Polarized Light. North-Holland Physics Publishing, Amsterdam Google Scholar
- 4.Arwin H (2001) Sens Actuators A 92:43 CrossRefGoogle Scholar
- 5.Gauglitz G (1996) in: Baltes H, Göpel W, Hesse J (eds) Sensors Update vol I. Wiley, Weinheim, p 1 Google Scholar
- 6.Liedberg B, Nylander C, Lundström I (1983) Sens Actuators B 4:299 CrossRefGoogle Scholar
- 7.Piraud C, Mwarania E, Wylangowski G, Wilkinson J, O'Dwyer K, Schiffrin DJ (1992) Anal Chem 64:651 CrossRefGoogle Scholar
- 8.Lakowicz JR (2004) Anal Biochem 324(2):153 CrossRefGoogle Scholar
- 9.Brandenburg A, Henninger R (1994) Appl Optics 33:5941 CrossRefGoogle Scholar
- 10.Brandenburg A, Hinkov V, Kunz R (1992) in: Göpel W, Hesse J, Zemel JN (eds) Sensors, vol 6. Wiley, Weinheim, p 399 Google Scholar
- 11.Clerc D, Lukosz W (1994) Sens Actuators B 19:581 CrossRefGoogle Scholar
- 12.Cush R, Cronin JM, Stewart WJ, Maule CH, Molloy J, Goddard NJ (1993) Biosens Bioelectron 8:347 CrossRefGoogle Scholar
- 13.Dieterle F, Belge G, Betsch C, Gauglitz G (2002) Anal Bioanal Chem 374:858 CrossRefGoogle Scholar
- 14.Kieser B, Dieterle F, Gauglitz G (2002) Anal Chem 74:4781 CrossRefGoogle Scholar
- 15.Busche S, Dieterle F, Kieser B, Gauglitz G (2003) Sens Actuators B 89:192 CrossRefGoogle Scholar
- 16.Dieterle F, Busche S, Gauglitz G (2003) Anal Chim Acta 490:71 CrossRefGoogle Scholar
- 17.Dieterle F, Busche S, Gauglitz G (2004) Anal Bioanal Chem 380:383 CrossRefGoogle Scholar
- 18.Kasper M, Gauglitz G (2004) GIT Labor-Fachzeitschrift 48:447 Google Scholar
- 19.Kasper M, Busche S, Dieterle F, Belge G, Gauglitz G (2004) Meas Sci Tech 15:540 CrossRefGoogle Scholar
- 20.Toshima N (1992) Polymers for Gas Seperation. Wiley, Weinheim Google Scholar
- 21.Michaels AS, Vieth WR, Barrie JA (1963) J Appl Phys 34:13 CrossRefGoogle Scholar
- 22.Dlubek G, Clarke A, Fretwell H, Dugdale SB, Alam MA (1996) Phys Status Solidi A 157:351 CrossRefGoogle Scholar
- 23.Maier G (1998) Angew Chem 110:3128 CrossRefGoogle Scholar