Skip to main content

Part of the book series: Environmental Science and Engineering ((ENVENG))

  • 1843 Accesses

Abstract

Trump wall is a kind of building envelope structure that can make full use of solar passive heating. The vent structure and its influence on the heating performance of the wall can be further optimized. In this paper, a laboratory bench was built in Lanzhou, China. The ventilating holes with different shapes and different inclination angles were studied by experimental methods. The result showed that the heating performance of the Trump wall was better with round ventilating hole and the venting angle of 30°. It provides a reference for the promotion and application on the Trump wall.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Sá, A.B., Paiva, A.: An experimental analysis of the Trombe wall temperature fluctuations for high range climate conditions: Influence of ventilation openings and shading devices. Energy and Build. 138,546–558 (2017)

    Google Scholar 

  2. Duan, S., et al.: Winter heating characteristics of solar wall. J. Liaoning Tech. Univ. 33(7), 938–942 (2014)

    Google Scholar 

  3. Liu, Y., et al.: A numerical and experimental analysis of the air vent management and heat storage characteristics of a Trombe wall. Sol. Energy 91(5), 1–10 (2013)

    Article  Google Scholar 

  4. Rabani, M., et al.: Experimental study of the heating performance of a Trombe wall with a new design. Original Res. Art. Sol. Energy 118, 359–374(2015)

    Article  Google Scholar 

  5. Bajc, T., et al.: CFD analyses for passive house with Trombe wall and impact to energy demand. Energy Build. 98, 39–44 (2015)

    Article  Google Scholar 

  6. Wang, D., et al.: Test and analysis of heating performance of Trombe wall solar house in qinghai-tibet plateau. J. Sol. Energy 34(10), 1823–1828 (2013)

    Google Scholar 

  7. Yanting, W., et al.: Two-dimension unsteady model and performance analysis for Trombe wall system with phase change materials. Acta Energiae Solaris Sinica 33(9), 948–952 (2012)

    Google Scholar 

  8. Wang, T., et al.: Thermal process and optimization design of solar collector type solar collectors. J. Sol. Energy 37(9), 2286–2291 (2016)

    Google Scholar 

Download references

Acknowledgements

This study is supported by the National Natural Science Foundation of China (No: 51466007).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Wenhen Zhou .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2020 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Wang, Y., Zhou, W., Wang, X., Li, S., Ouyang, H. (2020). Vent Effect Study on the Performance of Trump Wall. In: Wang, Z., Zhu, Y., Wang, F., Wang, P., Shen, C., Liu, J. (eds) Proceedings of the 11th International Symposium on Heating, Ventilation and Air Conditioning (ISHVAC 2019). ISHVAC 2019. Environmental Science and Engineering(). Springer, Singapore. https://doi.org/10.1007/978-981-13-9528-4_32

Download citation

Publish with us

Policies and ethics