Abstract
This chapter presents several typical cases of Chinese and European kitchen ventilation designs, including ventilation design for kitchens of the high-rise residential building and commercial building in China, the institutional school kitchen, and restaurant kitchen in Europe.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Chen LP, Gong YF (2002) Calculation of central exhaust system of residential kitchens. J Nanjing Tech Univ 26(2):75–77 (In Chinese)
Chen LP, Gong YF (2004) Development of design method of common chimney in exhaust system of residence kitchens. HVAC 32(4):107–109 (In Chinese)
GA/T 798-2008 Vapor exhaust & fire resisting check damper. The Ministry of Public Security of the People’s Republic of China, Beijing (in Chinese)
GB 18483-2001 Emission standard of cooking fume. State Environmental Protection Administration of China, Beijing (in Chinese)
GB 50016-2014 Code for fire protection design of buildings. Ministry of Housing and Urban-Rural Development of the People’s Republic of China, Beijing (in Chinese)
GB 50096-2011 Design code for residential buildings. Ministry of Housing and Urban-Rural Development of the People’s Republic of China, Beijing (in Chinese)
GB 50368-2005 Residential building code. Ministry of Housing and Urban-Rural Development of the People’s Republic of China & General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China, Beijing (in Chinese)
GB 50736-2012 Design code for heating ventilation and air conditioning of civil buildings. Ministry of Housing and Urban-Rural Development of the People’s Republic of China, Beijing (in Chinese)
GB/T 17713-2011 Range hood. General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China & Standardization Administration, Beijing (In Chinese)
JG/T 194-2018 Ventilating duct for residential kitchen and bathroom. Ministry of Housing and Urban-Rural Development of the People’s Republic of China, Beijing (in Chinese)
Zhou JH (2014) Study to determine the reasonable exhaust volume and flue in the form of residential kitchens impact on the flow of exhaust. Xi’an University of Architecture and Technology (In Chinese)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this chapter
Cite this chapter
Li, A., Kosonen, R. (2019). Case Study and Design of Kitchen Ventilation. In: Kitchen Pollutants Control and Ventilation. Springer, Singapore. https://doi.org/10.1007/978-981-13-6496-9_9
Download citation
DOI: https://doi.org/10.1007/978-981-13-6496-9_9
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-13-6495-2
Online ISBN: 978-981-13-6496-9
eBook Packages: EngineeringEngineering (R0)