Abstract
Counterpulsation is the form of circulatory support provided by the intra-aortic balloon pump (IABP), a device widely used in the clinical setting to assist the left ventricle by mechanical control of blood volume displacement within the aorta. The principles underlying the IABP function are well established but the interactions with the cardiovascular system make its performance rather complicated and still not completely understood. Here we propose a novel IABP numerical model as a tool with potential for clinical application in terms of simulation and outcome prediction in critical patients. The analysis of IABP assistance is presented in terms of the effects on stroke volume, mean aortic diastolic pressure, aortic end-systolic pressure, aortic end-diastolic pressure, endocardial viability ratio and pressure-volume loop shift. Balloon inflation/deflation rate and timing are also considered. The new model was implemented in CARDIOSIM© software simulator of the cardiovascular system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
He P, Dubin SE, Moore TW, Jaron D. Guidelines for Optimal Control of Intraaortic Balloon Pumping: Experimental Studies. ASAIO J. 7(4), 172–179 (1984).
Jaron D, Moore TW, He P. Control of Intraaortic Balloon Pumping: Theory and Guidelines for Clinical Applications. Ann. Biomed. Eng. 13, 155–175 (1985).
Thiele H, Zeymer U, Neumann FJ, et al. Intraaortic Balloon Support for Myocardial Infarction with Cardiogenic Shock. N. Engl. J. Med. 367, 1287–1296 (2012).
Ergle K, Parto P, Krim SR. Percutaneous Ventricular Assist Devices: A Novel Approach in the Management of Patients with Acute Cardiogenic Shock. Ochsner J. 16, 243–249 (2016).
Nuding S, Werdan K. IABP plus ECMO – Is one and one more than two? J. Thorac. Dis. 9(4), 961–964 (2017).
De Lazzari C. Interaction between the septum and the left (right) ventricular free wall in order to evaluate the effects on coronary blood flow: numerical simulation. Comput. Methods Biomech. Biomed. Engin. 15(12), 1359–1368 (2012).
De Lazzari C, Genuini I, Pisanelli D, et al. Interactive simulator for e-Learning environments: a teaching software for health care professionals. Biomed. Eng. Online 13(1), 172 (2014).
De Lazzari C, Darowski M, et al. Ventricular energetics during mechanical ventilation and intraaortic balloon pumping – Computer simulation. J. Med. Eng. & Tech., 25(3), 103–111 (2001).
De Lazzari C, Stalteri D. CARDIOSIM© Software Simulator: http://cardiosim.dsb.cnr.it/.
Acknowledgements
This work was supported by the Italian Ministry of Education, University and Research (M.I.U.R.) Flagship InterOmics Project (cod. PB05).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Marconi, S., Cappelli, C., Capoccia, M., Pisanelli, D.M., Genuini, I., De Lazzari, C. (2019). A New Numerical Model of the Intra-aortic Balloon Pump as a Tool for Clinical Simulation and Outcome Prediction. In: Lhotska, L., Sukupova, L., Lacković, I., Ibbott, G. (eds) World Congress on Medical Physics and Biomedical Engineering 2018. IFMBE Proceedings, vol 68/3. Springer, Singapore. https://doi.org/10.1007/978-981-10-9023-3_144
Download citation
DOI: https://doi.org/10.1007/978-981-10-9023-3_144
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-9022-6
Online ISBN: 978-981-10-9023-3
eBook Packages: EngineeringEngineering (R0)