Skip to main content

Integrated Screw-Hook Development

  • Chapter
  • First Online:
  • 270 Accesses

Part of the book series: Translational Medicine Research ((TRAMERE))

Abstract

The development of spinal products must obey strict quality assurance guidelines. The uniqueness of orthopedic R&D is reflected in the requirements of the main steps: product design, strength analysis and structural optimization, functional analysis and evaluation, and surgical evaluation. Design process of the Integrated Screw-Hook System by Sanyou Medical includes design evaluation and validation, cadaver surgery, FEM simulations, biomechanical experiments, mechanical experiments on the implants, biocompatibility test of materials, and risk assessment evaluation of design. Industrial production process and product quality control are also discussed.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   89.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   119.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Title 21-Food and drugs, Chapter I-Food and drug administration, Department of Health and Human Services, Subchapter H-medical devices, Subpart C-design controls, § 820.30–Design controls.

    Google Scholar 

  2. ISO 13485:2016, Medical devices-Quality management systems-Requirements for regulatory purposes.

    Google Scholar 

  3. Council directive 93/42/EEC of 14 June 1993 concerning medical devices.

    Google Scholar 

  4. Shirazi-Adl A, Ahmed AM, Shrivastava SC. Mechanical response of a lumbar motion segment in axial torque alone and combined with compression. Spine. 1986;11(9):914–27.

    Article  CAS  PubMed  Google Scholar 

  5. Schmidt H, Heuer F, Drumm J, Klezl Z, Claes L, Wilke HJ. Application of a calibration method provides more realistic results for a finite element model of a lumbar spinal segment. Clin Biomech (Bristol, Avon). 2007;22(4):377–84.

    Article  Google Scholar 

  6. Regulation of Quality Control Department in Sanyou Medical, Quality Control Department, Shanghai Sanyou Co., Ltd. 2011.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Michael Mingyan Liu .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd. and Shanghai Jiao Tong University Press

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Liu, M.M. (2018). Integrated Screw-Hook Development. In: Ni, B., Guo, X., Guo, Q. (eds) Atlantoaxial Fixation Techniques. Translational Medicine Research. Springer, Singapore. https://doi.org/10.1007/978-981-10-7889-7_16

Download citation

Publish with us

Policies and ethics