Abstract

Tonometry is a routine procedure in ophthalmological examination; it is performed for diagnosing not only glaucoma but also ocular hypotension caused by eye trauma, retinal detachment, or intraocular inflammation following intraocular surgery. For the diagnosis and treatment of glaucoma, it is necessary to continuously measure IOP over a set period of time or number of days. IOP monitoring devices have been developed to various types of tonometers such as Goldmann applanation tonometer, Perkins tonometer. Tono-Pen tonometer, noncontact tonometer, Pulsair tonometer, ocular response analyzer, rebound tonometer, and dynamic contour tonometry, etc.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 99.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 129.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Suggested Reading

  • Allingham RR, Damji KF, Freedman SF, Moroi SE, Rhee DJ. Shields textbook of glaucoma. 6th ed. Philadelphia: Lippincott Williams & Wilkins; 2010.

    Google Scholar 

  • Gabelt BT, Kaufman PL. Changes in aqueous humor dynamics with age and glaucoma. Prog Retin Eye Res. 2005;24(5):612–37.

    Article  CAS  Google Scholar 

  • Gedde SJ. Curbside consultation in glaucoma: 49 clinical questions. 2nd ed. Thorofare: Slack; 2015.

    Google Scholar 

  • Kaufmann C, Bachmann LM, Thiel MA. Comparison of dynamic contour tonometry with Goldmann applanation tonometry. Invest Ophthalmol Vis Sci. 2004;45(9):3118–21.

    Article  Google Scholar 

  • Lowe RF. Primary angle-closure glaucoma. A review of provocative tests. Br J Ophthalmol. 1967;51(11):727–32.

    Article  CAS  Google Scholar 

  • Schacknow PN, Samples JR. The glaucoma book: a practical, evidence-based approach to patient care. New York: Springer; 2010.

    Book  Google Scholar 

  • Shaarawy TM, Sherwood MB, Hitchings RA, Crowston JG. Glaucoma. 2nd ed: Elsevier; 2014.

    Google Scholar 

  • Shin J, Lee JW, Kim EA, Caprioli J. The effect of corneal biomechanical properties on rebound tonometer in patients with normal-tension glaucoma. Am J Ophthalmol. 2015;159(1):144–54.

    Article  Google Scholar 

  • Stamper RL, Lieberman MF, Drake MV. Becker-Shaffer’s diagnosis and therapy of the glaucomas. 8th ed. Edinburgh (Scotland): Mosby; 2009.

    Google Scholar 

  • Tonnu PA, Ho T, Sharma K, White E, Bunce C, Garway-Heath D. A comparison of four methods of tonometry: method agreement and interobserver variability. Br J Ophthalmol. 2005;89(7):847–50.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Singapore Pte Ltd.

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Shin, JH. (2019). Tonometry. In: Lee, JS. (eds) Primary Eye Examination. Springer, Singapore. https://doi.org/10.1007/978-981-10-6940-6_11

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-6940-6_11

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-6939-0

  • Online ISBN: 978-981-10-6940-6

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics