Scanning Helium Ion Microscope

  • Chapter
  • First Online:
Compendium of Surface and Interface Analysis
  • 341 Accesses

Abstract

Scanning helium ion microscope (SHIM) is based on the similar principle with field emission scanning electron microscope (FE-SEM) (Guo in Scanning Helium Ion Microscopy, Characterization of Materials. Wiley, pp. 1–9, 2012 [1]). The difference between them is that scanning beam of SHIM is a positively charged helium ion (He+) beam from a gas field ion source (GFIS), but not a negatively charged electron beam. An enlarged image of the sample surface is obtained like FE-SEM. Helium gas is field-ionized almost only from the top-most atoms by applying a high voltage to a sharp tip made of monocrystalline refractory metals in a diluted helium gas. Only the He+ beam emitted from a single atom is focused by the ion optical system and is scanned over the sample surfaces. If a backscattered ion detector is equipped, the secondary electrons (SE) and backscattered ions (BSI) can be acquired simultaneously. SHIM can observe the sample image with less current than FE-SEM. If the neutralizing flood gun is equipped, it is easier to observe insulating materials than FE-SEM. SHIM can also be used for direct nanofabrication like focused ion beam (FIB) systems. Since He+ beam does not have such a sputtering capability as a gallium ion beam, it cannot process on the micron-scale, but nanoscale ultrafine modification utilizing the nanoscale-focused He+ beam is possible. If a gas introduction system is installed, deposition of gas-decomposition microstructures by a precisely controlled He+ beam is possible

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

References

  1. Guo, H.X., Fujita, D.: Scanning Helium Ion Microscopy, Characterization of Materials, pp. 1–9. Wiley (2012)

    Google Scholar 

  2. Onishi, K.: Development and Shared Use of Advanced Nanomaterial Evaluation Techniques Using Scanning Helium Ion Microscope. Kenbikyo 48, 154–158 (2013)

    CAS  Google Scholar 

  3. Guo, H.X., Wang, C.X., Miyazawa, K., Masuda, H., Fujita, D.: Thermal decomposition of fullerene nanowhiskers protected by amorphous carbon mask. Scientific Reports 6, 38760 (2016)

    Article  CAS  Google Scholar 

  4. Sakai, C., Ishida, N., Masuda, H., Nagano, S., Kitahara, M., Fujita, D.: Active voltage contrast imaging of cross-sectional surface of multilayer ceramic capacitor using helium ion microscopy. Appl. Phys. Lett. 109, 051603 (2016)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Keiko Onishi .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd.

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Onishi, K., Fujita, D. (2018). Scanning Helium Ion Microscope. In: The Surface Science Society of Japan (eds) Compendium of Surface and Interface Analysis. Springer, Singapore. https://doi.org/10.1007/978-981-10-6156-1_92

Download citation

Publish with us

Policies and ethics