Zusammenfassung
Open gantry C-arm systems that are placed within the interventional room enable 3-D imaging and guidance for stroke therapy without patient transfer. This can profit in drastically reduced time-totherapy, however, due to the interventional setting, the data acquisition is comparatively slow. Thus, involuntary patient motion needs to be estimated and compensated to achieve high image quality. Patient motion results in a misalignment of the geometry and the acquired image data. Consistency measures can be used to restore the correct mapping to compensate the motion. They describe constraints on an idealized imaging process which makes them also sensitive to beam hardening, scatter, truncation or overexposure. We propose a probabilistic approach based on the Student’s t-distribution to model image artifacts that affect the consistency measure without sourcing from motion.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Literatur
Psychogios M, Behme D, Schregel K, et al. One-stop management of acute stroke patients: minimizing door-to-reperfusion times. Stroke. 2017;.
Müller K, Maier A, Lauritsch G, et al. Image artefact propagation in motion estimation and reconstruction in cardiac C-arm CT. Proc PMB. 2014;.
Preuhs A, Maier A, Manhart M, et al. Double your views: exploiting symmetry in transmission imaging. Proc MICCAI. 2018;.
Frysch R, Rose G. Rigid motion compensation in C-arm CT using consistency measure on projection data. Proc MICCAI. 2015;.
Abdurahman S, Frysch R, Bismark R, et al. Beam hardening correction using cone beam consistency conditions. IEEE Trans med Imaging. 2018;.
Würfl T, Maaß N, Dennerlein F, et al. Epipolar consistency guided beam hardening reduction-ECC 2. Fully 3D. 2017;.
Hoffmann M, Würfl T, Maaß N, et al. Empirical scatter correction using the epipolar consistency condition. CT-Meet. 2018;.
Punzet D, Frysch R, Rose G. Extrapolation of truncated C-arm CT data using grangeat-based consistency measures. CT-Meet. 2018;.
Preuhs A, Berger M, Xia Y, et al. Over-exposure correction in CT using optimization-based multiple cylinder fitting. Proc BVM. 2015;.
Debbeler C, N, Elter M, et al. A new CT rawdata redundancy measure applied to automated misalignment correction. Fully 3D. 2013;.
Aichert A, Berger M, Wang J, et al. Epipolar consistency in transmission imaging. IEEE Trans Med Imaging. 2015;.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Fachmedien Wiesbaden GmbH, ein Teil von Springer Nature
About this paper
Cite this paper
Preuhs, A. et al. (2019). Maximum Likelihood Estimation of Head Motion Using Epipolar Consistency. In: Handels, H., Deserno, T., Maier, A., Maier-Hein, K., Palm, C., Tolxdorff, T. (eds) Bildverarbeitung für die Medizin 2019. Informatik aktuell. Springer Vieweg, Wiesbaden. https://doi.org/10.1007/978-3-658-25326-4_29
Download citation
DOI: https://doi.org/10.1007/978-3-658-25326-4_29
Published:
Publisher Name: Springer Vieweg, Wiesbaden
Print ISBN: 978-3-658-25325-7
Online ISBN: 978-3-658-25326-4
eBook Packages: Computer Science and Engineering (German Language)