Abstract
Accuracy of intensity-based non-rigid registration of vascular images is deteriorated in the presence of excessive noise as occurring in CBCT angiography. A new approach to non-rigid registration of vascular images is presented based on the assumption of isometric deformation of vessel structures. For every voxel in the vascular image, the distances along the vessels to some reference voxels are computed as features that are invariant under isometric deformation. Due to the global information on vessel connectivity that is encoded in these features, voxel-based registration of these feature images can compensate for local optima in direct intensity-based registration of the vascular images. The method is validated in the context of brain-shift mitigation, but the technique can be used more broadly. Tests on artificially deformed vascular images show that our algorithm reaches higher accuracy than traditional intensity-based registration.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Roberts, D.W., et al.: Intraoperative brain shift and deformation: a quantitative analysis of cortical displacement in 28 cases. Neurosurgery 43(4), 749–758 (1998)
Hartkens, T., et al.: Measurement and analysis of brain deformation during neurosurgery. IEEE Transactions on Medical Imaging 22(1), 82–92 (2003)
Hill, D., et al.: Estimation of Intraoperative Brain Surface Movement. In: Troccaz, J., Mösges, R., Grimson, W.E.L. (eds.) CVRMed-MRCAS 1997. LNCS, vol. 1205, pp. 449–458. Springer, Heidelberg (1997)
Archip, N., et al.: Non-rigid alignment of pre-operative MRI, fMRI, and DT-MRI with intra-operative MRI for enhanced visualization and navigation in image-guided neurosurgery. NeuroImage 35(2), 609–624 (2007)
Reinertsen, I., et al.: Validation of vessel-based registration for correction of brain shift. Medical Image Analysis 11(4), 374–388 (2007)
Letteboer, M.M.J., et al.: Brain shift estimation in image-guided neurosurgery using 3-D ultrasound. IEEE Transactions on Bio-medical Engineering 52(2), 268–276 (2005)
Suetens, P.: Fundamentals of medical imaging. Cambridge University Press (2009)
Maes, F., et al.: Multimodality image registration by maximization of mutual information. IEEE Transactions on Medical Imaging 16(2), 187–198 (1997)
Jomier, J., Aylward, S.R.: Rigid and deformable vasculature-to-image registration: A hierarchical approach. In: Barillot, C., Haynor, D.R., Hellier, P. (eds.) MICCAI 2004. LNCS, vol. 3216, pp. 829–836. Springer, Heidelberg (2004)
Sethian, J.: Fast marching methods. SIAM Review 41(2), 199–235 (1999)
Klein, S., et al.: Elastix: a Toolbox for Intensity-Based Medical Image Registration. IEEE Transactions on Medical Imaging 29(1), 196–205 (2010)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Robben, D. et al. (2013). Intra-patient Non-rigid Registration of 3D Vascular Cerebral Images. In: Drechsler, K., et al. Clinical Image-Based Procedures. From Planning to Intervention. CLIP 2012. Lecture Notes in Computer Science, vol 7761. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-38079-2_14
Download citation
DOI: https://doi.org/10.1007/978-3-642-38079-2_14
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-38078-5
Online ISBN: 978-3-642-38079-2
eBook Packages: Computer ScienceComputer Science (R0)