Skip to main content

EEG fractal dimension combined with burst suppression ratio as a measure of depth of anesthesia

  • Conference paper
World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China

Part of the book series: IFMBE Proceedings ((IFMBE,volume 39))

Abstract

This paper proposes an alternative index for the monitoring of depth of anesthesia. The study was carried out on 6 EEG recordings acquired during surgery under general anesthesia. Induction was provided by propofol, anesthesia was then maintained either with propofol or with sevoflurane under BIS control. The proposed FDSR parameter, combination of Higuchi’s fractal dimension and burst suppression ratio, is able to distinguish among different clinical states and detected two episodes of intraoperative awareness not highlighted by BIS. Moreover, due to its low computational complexity, FDSR is more suitable than BIS for real-time implementation. In conclusion, FDSR is a promising index for the monitoring of depth of anesthesia and the reduction of the incidence of intraoperative awareness.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Cusenza .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Cusenza, M., Accardo, A., Orsini, A. (2013). EEG fractal dimension combined with burst suppression ratio as a measure of depth of anesthesia. In: Long, M. (eds) World Congress on Medical Physics and Biomedical Engineering May 26-31, 2012, Beijing, China. IFMBE Proceedings, vol 39. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-29305-4_131

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-29305-4_131

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-29304-7

  • Online ISBN: 978-3-642-29305-4

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics