Abstract

We developed a compact tactile sensor in order to guide the clinician or the self-user for non-invasive detection of lumps. The new design has an advantage over the existing discrete tactile sensors and detection methods by efficiently sensing force distribution over an area without any side effects. The sensor consists of 10×10 infrared emitter-detector pairs, a silicon-rubber elastic pad, and a contoured tactile interface (25x21 moving pins) for palpating three-dimensional objects. To demonstrate the practical use of the sensor, first a cylindrical tissue-like silicon phantom was prepared, then a 13 mm diameter rigid spherical object was placed at varying depths of 0-20 mm to simulate cancerous lumps in breast tissue, and finally the tactile sensor was systematically pressed on the phantom to successfully detect the lumps for compression depths of 10-24 mm. The location and the estimated radius of each lump were calculated from the recorded tactile images.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Organization, W. H. World Health Statistics 2009. World Health Organization, Geneva (2009)

    Google Scholar 

  2. Ferlay, J., Autier, P., Boniol, M., Heanue, M., Colombet, M., Boyle, P.: Estimates of the cancer incidence and mortality in Europe in 2006. Ann Oncol. 18(3), 581–592 (2007)

    Article  Google Scholar 

  3. Sarvazyan, A., Egorov, V.: Cost-Effective Screening for Breast Cancer Worldwide: Current State and Future Directions. Breast Cancer: Basic and Clinical Research, 91–99 (2008)

    Google Scholar 

  4. Lang, P.: Optical Tactile Sensor for Medical Palpation. In: The Thirty-Fourth London District Science and Technology Conference, pp. 1–5 (March 2004)

    Google Scholar 

  5. Wang, Y., Nguyen, C., Srikanchana, R., Geng, Z., Freedman, M.T.: Tactile Mapping of Palpable Abnormalities for Breast Cancer Diagnosis. In: Proc. of the Int. Conf. on Robotics and Automation, pp. 1305–1309 (May 1999)

    Google Scholar 

  6. Zeng, J., Wang, Y., Freedman, M.T., Mun, S.K.: Finger Tracking for Breast Palpation Quantification using Color Image Features. SPIE J. of Opt. Eng. 36(12), 3455–3461 (1997)

    Article  Google Scholar 

  7. Haagensen, C.D.: Diseases of the Breast, 3rd edn. Saunders, Philadelphia (1986)

    Google Scholar 

  8. Kitagawa, M., Okamura, A.M., Bertha, B.T., Gott, V.L., Baumgartner, W.A.: Analysis of Suture Manipulation Forces for Teleoperation with Force Feedback. In: Dohi, T., Kikinis, R. (eds.) MICCAI 2002. LNCS, vol. 2488, pp. 155–162. Springer, Heidelberg (2002)

    Chapter  Google Scholar 

  9. Ohtsuka, T., Furuse, A., Kohno, T., Nakajima, J., Yagyu, K., Omata, S.: New Tactile Sensor Techniques for Localization of Pulmonary Nodules. International Surgery 82, 12–14 (1997)

    Google Scholar 

  10. Wellman, P.S., Dalton, E.P., Krag, D., Kern, K.A., Howe, R.D.: Tactile Imaging of Breast Masses: First Clinical Report. Archives of Surgery 136, 204–208 (2001)

    Article  Google Scholar 

  11. Carmichael, A., Sami, A., Dixon, J.: Breast cancer risk among the survivors of atomic bomb and patients exposed to therapeutic ionising radiation. European Journal of Surgical Oncology 29(5), 475–479

    Google Scholar 

  12. Shellock, F.G.: Biomedical Implants and Devices: Assessment of Magnetic Field Interactions with a 3.0-Tesla MR System. Journal Of Magnetic Resonance Imaging (2002)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Ayyildiz, M., Guclu, B., Yildiz, M.Z., Basdogan, C. (2010). A Novel Tactile Sensor for Detecting Lumps in Breast Tissue. In: Kappers, A.M.L., van Erp, J.B.F., Bergmann Tiest, W.M., van der Helm, F.C.T. (eds) Haptics: Generating and Perceiving Tangible Sensations. EuroHaptics 2010. Lecture Notes in Computer Science, vol 6191. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-14064-8_53

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-14064-8_53

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-14063-1

  • Online ISBN: 978-3-642-14064-8

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics