Skip to main content

Part of the book series: IFMBE Proceedings ((IFMBE,volume 25/2))

Abstract

A magnetic resonance imaging (MRI) technique for diffusion weighted imaging (DWI) is described which is, in contrast to echo-planar imaging (EPI), insensitive to offresonances, due to tissue susceptibility differences, magnetic field inhomogeneities or chemical shifts. The sequence combines a diffusion weighted (DW) spin-echo preparation and a single-shot stimulated echo acquisition mode (STEAM) module. The application of an inner-volume excitation by the ZOOM imaging technique allows a reduced rectangular fieldof- view (FOV) in PE direction, but suppresses aliasing artifacts which are usually the consequence of too small FOVs. Sagittal single-shot images of the lumbar spine were acquired at 3.0 T with 2.34 × 2.34 mm2 in-plane resolution and 7 mm slice thickness. For the calculation of the apparent diffusion coefficient (ADC) and to determine the diffusibility of water in lumbar intervertebral disks (IVDs) the DW gradients were applied in orthogonal gradient orientations with b = 100 sec/mm2, b = 150 sec/mm2 and b = 250 sec/mm2.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 International Federation for Medical and Biological Engineering

About this paper

Cite this paper

Hiepe, P., Ros, C., Reichenbach, J.R., Herrmann, K.H. (2009). Diffusion Weighted ZOOM Imaging in the Lumbar Spine Based on Single-Shot STEAM. In: Dössel, O., Schlegel, W.C. (eds) World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany. IFMBE Proceedings, vol 25/2. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-03879-2_188

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-03879-2_188

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-03878-5

  • Online ISBN: 978-3-642-03879-2

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics