Abstract

In this work, two methods for T wave segmentations were compared: classic method based on differentiator filter and the method based on slope estimation. This study was carried out on simulated electrocardiogram (ECG) signals with four simulated added noise types: (a) baseline wander due to breathing (0–0.5 Hz), (b) motion artifacts (3–5 Hz), (c) electromyography and motion artifacts (Gaussian white noise), (c) mixed effects (sum of the previous noises). Four conditions of Signal to Noise Ratio (SNR) were computed: 5, 10, 15, 20 and 25 dB. The beginning, the end and the width of the T wave was determined with both methods and the mean absolute error was computed for all signals. The slope estimation method shows a T wave width larger than the obtained with the differentiator filter. Both methods showed that the end location is easier to find than the beginning of the T wave. The achieved performance shows a satisfying behavior of both methods in favorable conditions of SNR. However, the differentiator filter method shows better performance that the method base on slope estimation. The noise due to motion artifacts affect greatly the mean absolute error in the beginning and end location of the T wave. An important increase of T wave width variability induced by the artifacts was observed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Referencias

  1. Mincholé A, Martínez JP, Arini P, Risk M, Laguna P. (2006) T Wave Width Alterations during Valsalva Maneuver in Diabetic Patients. Proceeding Computers in Cardiology IEEE Computer Society Press, 33:709–712.

    Google Scholar 

  2. Arini PD, Martinez JP, Laguna P. (2006) Evolution of T Wave Width During Severe Ischemia Generated by Percutaneous Transluminal Coronary Angioplasty. Proceeding Computers in Cardiology IEEE Computer Society Press, 33:713–716.

    Google Scholar 

  3. Laguna P, Thakor NV, Caminal P, Jane R, Yoon HR, Bayes de Luna A, Marti V, Guindo, J. (1990) New algorithm for QT interval analysis in 24-hour Holter ECG: performance and applications. Med Biol Eng Comput, 28(1):67–73

    Article  Google Scholar 

  4. Lepeschkin E, Surawicz B. (1952) The Measurement of the Q-T Interval of the Electrocardiogram. Circulation, 6:378–388.

    Google Scholar 

  5. Tikkanen PE, Sellin LC, Kinnunen HO, Huikuri HV. (1999) Using simulated noise to define optimal QT intervals for computer analysis of ambulatory ECG. Med Eng Phys, 21(11):15–25

    Article  Google Scholar 

  6. Pan J, Tompkins WJ. (1985) A real-time QRS detection algorithm. IEEE Trans. Biomed. Eng., 32(3): 230–236

    Article  Google Scholar 

  7. Porta A, Baselli G, Lombardi F, Cerutti S, Antolini R, Del Greco M, Ravelli F, Nollo G. (1998) Performance assessment of standard algorithms for dynamic R-T interval measurement: comparison between R-T apex and R-T end approach. Medical & Biological Engineering & Computing, 36(1):35–42.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2007 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Altuve, M., Casanova, O., Wong, S., Passariello, G., Hernandez, A., Carrault, G. (2007). Evaluación de dos Métodos para la Segmentación del Ancho de la Onda T en el ECG. In: Müller-Karger, C., Wong, S., La Cruz, A. (eds) IV Latin American Congress on Biomedical Engineering 2007, Bioengineering Solutions for Latin America Health. IFMBE Proceedings, vol 18. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-74471-9_291

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-74471-9_291

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-74470-2

  • Online ISBN: 978-3-540-74471-9

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics