Abstract
Ceramic on Ceramic (CoC) bearings for Total Hip Arthroplasty (THA) were introduced with the aim of reducing wear associated with polyethylene (PE) components, thus limiting osteolysis and increasing the longevity of the implant especially in young and active patients. While this material offers great durability, fractures of the ceramics compounds remains a cause for concern, since can lead to catastrhopic failures and complications after revision. The prevalence of ceramics fractures ranges from 0.009% to 0.126%, with liner fractures being more frequent. The most common causes of fractures are fatigure of the components, malopistioning or mishandling. The clinical picture of an head fracture is straightforward; however, liner fractures can be more subtle and needs proper investigations. Once the diagnosis of ceramic fracture is made, revision surgery should not be postponed, but rather planned with ‘relative emergency’, because of the risk of fragments spreading in the soft tissues and further damaging the metal components. A debridement of the articular soft tissues with removal of cermaics fragments is mandatory in revision surgery. All damaged or malpositioned implant components should be revised and a new ceramic head and polyethilene or ceramic liner should be the beraing option. Metal heads and liners are definitively contraindicated. This chapter is aimed to present an evidence based, updated approach on how to prevent and treat this rare but devasting complication including diagnostic and surgical tips and tricks, considering risk factors and reason for failure.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Kang BJ, Ha YC, Ham DW, Hwang SC, Lee YK, Koo KH. Third-generation alumina-on-alumina total hip arthroplasty: 14 to 16-year follow-up study. J Arthroplast. 2015;30(3):411–5.
Petsatodis GE, Papadopoulos PP, Papavasiliou KA, Hatzokos IG, Agathangelidis FG, Christodoulou AG. Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing: results after a minimum of twenty years of follow-up. J Bone Joint Surg Am. 2010;92(3):639–44.
Sedel L, Walter WL, Pitto RP. Clinical faceoff: ceramic-on-ceramic THA: do the advantages outweigh the limitations? Clin Orthop Relat Res. 2014;472(10):2927–31.
Macdonald N, Bankes M. Ceramic on ceramic hip prostheses: a review of past and modern materials. Arch Orthop Trauma Surg. 2014;134(9):1325–33.
Hannouche D, Zingg M, Miozzari H, Nizard R, Lubbeke A. Third-generation pure alumina and alumina matrix composites in total hip arthroplasty: what is the evidence? EFORT Open Rev. 2018;3(1):7–14.
Zagra L. CORR insights((R)): do the reasons for ceramic-on-ceramic revisions differ from other bearings in total hip arthroplasty? Clin Orthop Relat Res. 2016;474(10):2200–1.
Koo KH, Ha YC, Kim SY, Yoon KS, Min BW, Kim SR. Revision of ceramic head fracture after third generation ceramic-on-ceramic total hip arthroplasty. J Arthroplast. 2014;29(1):214–8.
Association AO. Australian arthroplasty register 2016. Available from: https://aoanjrr.sahmri.com/annual-reports-2016.
Howard DP, Wall PDH, Fernandez MA, Parsons H, Howard PW. Ceramic-on-ceramic bearing fractures in total hip arthroplasty: an analysis of data from the National Joint Registry. Bone Joint J. 2017;99-b(8):1012–9.
D’Antonio JA, Sutton K. Ceramic materials as bearing surfaces for total hip arthroplasty. J Am Acad Orthop Surg. 2009;17(2):63–8.
Hamilton WG, McAuley JP, Dennis DA, Murphy JA, Blumenfeld TJ, Politi J. THA with delta ceramic on ceramic: results of a multicenter investigational device exemption trial. Clin Orthop Relat Res. 2010;468(2):358–66.
Hamilton WG, McAuley JP, Blumenfeld TJ, Lesko JP, Himden SE, Dennis DA. Midterm results of delta ceramic-on-ceramic total hip arthroplasty. J Arthroplast. 2015;30(9 Suppl):110–5.
Traina F, De Fine M, Di Martino A, Faldini C. Fracture of ceramic bearing surfaces following total hip replacement: a systematic review. Biomed Res Int. 2013;2013:157247.
Dalla Pria P, Zagra L, Esopi P, Masoni D. Breakage and noises in ceramic on ceramic couplings. Eur Orthop Traumatol. 2010;1(2):53–9.
Traina F, De Fine M, Bordini B, Toni A. Risk factors for ceramic liner fracture after total hip arthroplasty. Hip Int. 2012;22(6):607–14.
Johansson HR, Johnson AJ, Zywiel MG, Naughton M, Mont MA, Bonutti PM. Does acetabular inclination angle affect survivorship of alumina-ceramic articulations? Clin Orthop Relat Res. 2011;469(6):1560–6.
Elkins JM, Pedersen DR, Callaghan JJ, Brown TD. Fracture propagation propensity of ceramic liners during impingement-subluxation: a finite element exploration. J Arthroplast. 2012;27(4):520–6.
Jeffers JR, Walter WL. Ceramic-on-ceramic bearings in hip arthroplasty: state of the art and the future. J Bone Joint Surg Br. 2012;94(6):735–45.
Squire M, Griffin WL, Mason JB, Peindl RD, Odum S. Acetabular component deformation with press-fit fixation. J Arthroplast. 2006;21(6 Suppl 2):72–7.
Zagra L, Gallazzi E. Bearing surfaces in primary total hip arthroplasty. EFORT Open Rev. 2018;3(5):217–24.
Lee SC, Jung KA, Nam CH, Kim TH, Ahn NK, Hwang SH. Acetabular screw head-induced ceramic acetabular liner fracture in cementless ceramic-on-ceramic total hip arthroplasty. Orthopedics. 2010;33(5)
Parvizi J, Adeli B, Wong JC, Restrepo C, Rothman RH. A squeaky reputation: the problem may be design-dependent. Clin Orthop Relat Res. 2011;469(6):1598–605.
Toni A, Traina F, Stea S, Sudanese A, Visentin M, Bordini B, et al. Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience. J Bone Joint Surg Am. 2006;88(Suppl 4):55–63.
Stea S, Traina F, Beraudi A, Montesi M, Bordini B, Squarzoni S, et al. Synovial fluid microanalysis allows early diagnosis of ceramic hip prosthesis damage. J Orthop Res. 2012;30(8):1312–20.
Zagra L, Maccario C, Mondini A, Bianchi L. Treatment of failures related to articulation material in THA. A comprehensive algorithm of surgical options and open questions. Hip Int. 2014;24(Suppl 10):S48–57.
Sharma V, Ranawat AS, Rasquinha VJ, Weiskopf J, Howard H, Ranawat CS. Revision total hip arthroplasty for ceramic head fracture: a long-term follow-up. J Arthroplast. 2010;25(3):342–7.
Zagra L, Bianchi L, Giacometti Ceroni R. Revision of ceramic fracture with ceramic-on-polyethylene in total hip arthroplasty: medium-term results. Injury. 2016;47(Suppl 4):S116–s20.
Traina F, Tassinari E, De Fine M, Bordini B, Toni A. Revision of ceramic hip replacements for fracture of a ceramic component: AAOS exhibit selection. J Bone Joint Surg Am. 2011;93(24):e147.
Gozzini PA, Schmid C, Dalla PP. Massive wear in a CoCrMo head following the fracture of an alumina head. Hip Int. 2002;12(1):37–42.
Allain J, Roudot-Thoraval F, Delecrin J, Anract P, Migaud H, Goutallier D. Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study. J Bone Joint Surg Am. 2003;85-a(5):825–30.
Sharma OP, Lochab J, Berkovich Y, Safir OA, Gross AE. Severe metallosis leading to femoral head perforation. Orthopedics. 2013;36(2):e241–3.
Ikeda T, Takahashi K, Kabata T, Sakagoshi D, Tomita K, Yamada M. Polyneuropathy caused by cobalt-chromium metallosis after total hip replacement. Muscle Nerve. 2010;42(1):140–3.
Zywiel MG, Brandt JM, Overgaard CB, Cheung AC, Turgeon TR, Syed KA. Fatal cardiomyopathy after revision total hip replacement for fracture of a ceramic liner. Bone Joint J. 2013;95-b(1):31–7.
Hintner M, Kaddick C, Usbeck S, Scheuber L, Streicher RM. What an orthopedic surgeon should know: selection of a bearing couple in case of revision after a fractured ceramic component. Semin Arthroplast. 2012;23(4):241–7.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Zagra, L., Gallazzi, E. (2019). Revision Surgery After Fractures of Ceramic Components. In: García-Rey, E., García-Cimbrelo, E. (eds) Acetabular Revision Surgery in Major Bone Defects. Springer, Cham. https://doi.org/10.1007/978-3-319-98596-1_7
Download citation
DOI: https://doi.org/10.1007/978-3-319-98596-1_7
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-98595-4
Online ISBN: 978-3-319-98596-1
eBook Packages: MedicineMedicine (R0)