Skip to main content

Organ Preservation and Implantation

  • Chapter
  • First Online:
  • 2569 Accesses

Part of the book series: Cardiovascular Medicine ((CVM))

Abstract

Heart transplantation (HTX) is still the golden standard in the treatment of terminal heart failure. Quality of life after HTX is rated very good and the mid- to long-term results are acceptable. However, organ shortage and chronic transplantation atherosclerosis represent major challenges in this field. Therefore, improvements in organ preservation and implantation are of utmost importance and are described in detail in this report.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   109.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD   139.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Allen BS, Okamoto F, Buckberg GD, Bugyi H, Young H, Leaf J, Beyersdorf F, et al. Immediate functional recovery after six hours of regional ischemia by careful control of conditions of reperfusion and composition of reperfusate. J Thorac Cardiovasc Surg. 1986;92(3 Pt 2):621–35.

    CAS  PubMed  Google Scholar 

  2. Ardahali A, Esmailian F, Deng M, Soltesz E, Hsich E, Naka Y, et al. Ex vivo perfusion of donor hearts for human heart transplantation (PROCEED II): a prospective, open-label, multicentre, randomized non-inferiority trial. Lancet. 2015;385:2577–84.

    Article  Google Scholar 

  3. Astrup J, Siesjö BK, Symon L. Thresholds in cerebral ischemia – the ischemic penumbra. Stroke. 1981;12(6):723–5.

    Article  CAS  Google Scholar 

  4. Barnard CN. The operation. A human cardiac transplant: an interim report of a successful operation performed at Groote Schuur Hospital, Cape Town. S Afr Med J. 1967;41:1271–4.

    CAS  Google Scholar 

  5. Beyersdorf F. The use of controlled reperfusion strategies in cardiac surgery to minimize ischaemia/reperfusion damage. Cardiovasc Res. 2009;83:262–8.

    Article  CAS  Google Scholar 

  6. Beyersdorf F, Unger A, Wildhirt A, Kretzer U, Deutschländer N, Krüger S, Matheis G, Hanselmann A, Zimmer G, Satter P. Studies of reperfusion injury in skeletal muscle: preserved cellular viability after extended periods of warm ischemia. J Cardiovasc Surg. 1991;32(5):664–76.

    CAS  Google Scholar 

  7. Buckberg GD. Studies of controlled reperfusion after ischemia. J Thorac Cardiovasc Surg. 1986;92:483–7.

    CAS  PubMed  Google Scholar 

  8. Dhital KK, Iyer A, Connellan M, Chew HC, Gao L, Doyle A, et al. Adult heart transplantation with distant procurement and ex-vivo preservation of donor hearts after circulatory death: a case series. Lancet. 2015;385:2585–91.

    Article  Google Scholar 

  9. Dreyfus G, Jebara VA, Couetil JP, Carpentier A. Kinking of the pulmonary artery: a treatable cause of acute right heart failure after heart transplantation. J Heart Transplant. 1990;9:575–6.

    CAS  PubMed  Google Scholar 

  10. Eltzschig H, Eckle T. Ischemia and Reperfusion – from mechanism to translation. Nat Med. 2011;17:1391–401.

    Article  CAS  Google Scholar 

  11. Emin A, Rogers CA, Banner NR, et al. Quality of life of advanced chronic heart failure: medical care, mechanical circulatory support and transplantation. Eur J Cardiothorac Surg. 2016;50:269–73.

    Article  Google Scholar 

  12. Fellström B. Transplantation atherosclerosis. J Intern Med. 1996;240:253–7.

    Article  Google Scholar 

  13. Garcia Sáez D, Zych B, Sabashnikov A, Bowles CT, de Robertis F, Mohite PN, et al. Evaluation of the organ care system in heart transplantation with an adverse donor/recipient profile. Ann Thorac Surg. 2014;98:2099–105.

    Article  Google Scholar 

  14. Garcia Sáez D, Zych B, Mohite PN, Sabashnikov A, Patil NP, Popov A, et al. LVAD bridging to heart transplantation with an ex-vivo allograft preservation shows significantly improved outcomes: a new standard of care? J Heart Lung Transpl. 2015;34:S95.

    Article  Google Scholar 

  15. Garcia Sáez D, Elbetanony A, Lezberg P, Hassanein A, Bowles CT, Popov AF, et al. Ex-vivo heart perfusion after cardiocirculatory death: a porcine model. J Surg Res. 2015;195:311–4.

    Article  Google Scholar 

  16. Hamed A, Tsui S, Huber J, Lin R, Poggio RC, Ardehali A. Serum lactate is a highly sensitive and specific predictor of postcardiac transplant outcomes using the Organ Care System. J Heart Lung Transpl. 2009;28:S71.

    Article  Google Scholar 

  17. Hossmann KA, Schmidt-Kastner R, Grosse Ophoff B. Recovery of integrative central nervous function after one hour global cerebro-circulatory arrest in normothermic cat. J Neurol Sci. 1987;77(2–3):305–20.

    Article  CAS  Google Scholar 

  18. Iyer A, Gao L, Doyle A, Rao P, Cropper JR, Soto C, et al. Normothermic ex vivo perfusion provides superior organ preservation and enables viability assessment of hearts from DCD donors. Am J Transplant. 2015;15:371–80.

    Article  CAS  Google Scholar 

  19. Koerner MM, Ghodsizad A, Schulz U, El Baayosy A, Koerfer R, Tenderich G. Normothermic ex vivo allograft blood perfusion in clinical heart transplantation. Heart Surg Forum. 2014;17:E141–5.

    Article  Google Scholar 

  20. Leprince P, Popov AF, Simon AR, Benk C, Siepe M. Ex vivo perfusion of the heart with the use of the Organ Care System. Eur J Cardiothorac Surg. 2016;49:1318–20.

    Article  Google Scholar 

  21. Lower RR, Shumway NE. Studies on the orthotopic homotransplantations of the canine heart. Surg Forum. 1960;11:18–23.

    CAS  PubMed  Google Scholar 

  22. Mitrev Z, Beyersdorf F, Hallmann R, Poloczek Y, Ihnken K, Herold H, Unkelbach U, Zimmer G, Freisleben HJ, Satter P. Reperfusion injury in skeletal muscle: controlled limb reperfusion reduces local and systemic complications after prolonged ischaemia. Cardiovasc Surg. 1994;2(6):737–48.

    CAS  PubMed  Google Scholar 

  23. Ou R, Lim YW, Choong JW, et al. Low-flow hypothermic crystalloid perfusion is superior to cold storage during prolonged heart preservation. Transplant Proc. 2014;46:3309–13.

    Article  CAS  Google Scholar 

  24. Rosenfeldt F, Ou R, Salamonsen R, Marasco S, Zimmet A, Byrne J, Cosic F, Saxena P, Esmore D. A novel combination technique of cold crystalloid perfusion but not cold storage facilitates transplantation of canine hearts donated after circulatory arrest. J Heart Lung Transplant. 2016;35:1358–64.

    Article  Google Scholar 

  25. Sarsam MA, Campbell CS, Yonan NA, Deiraniya AK, Rahman AN. An alternative surgical technique in orthotopic cardiac transplantation. J Card Surg. 1993;8:344–9.

    Article  CAS  Google Scholar 

  26. Schmitto JD, Zimpfer D, Fiane AE, Larbalestier R, Tsui S, Jansz P, Simon A, Schueler S, Strueber M. Long-term support of patients recieving a left ventricular assist device for advanced heart failure: a follow-up analysis of the Registry to Evaluate the HeartWare Left Ventricular Assist System. Eur J Cardiothorac Surg. 2016;50:834–8.

    Article  Google Scholar 

  27. Schnoor M, Schäfer T, Lühmann D, Sievers HH. Bicaval versus standard technique in orthotopic heart transplantation: A systematic review and meta-analysis. J Thorac Cardiovasc Surg. 2007;134:1322–31.

    Article  Google Scholar 

  28. Shumway SJ. Operative Techniques in Heart Transplantation. In: Shumway SJ, Shumway NE, editors. Thoracic Transplantation. Cambridge, MA: Blackwell Science; 1995. p. 163–73.

    Google Scholar 

  29. Sievers HH, Weyand M, Kraatz EG, Bernhard A. An alternative technique for orthotopic cardiac transplantation, with preservation of the normal anatomy of the right atrium. Thorac Cardiovasc Surg. 1991;39:70–2.

    Article  CAS  Google Scholar 

  30. Sjostrand F, Allen BS, Buckberg GD, Okamoto F, Young H, Bugyi H, Beyersdorf F, Barnard RJ, Leaf J. Electron microscopic studies: importance of embedding techniques in quantitative evaluation of cardiac mitochondrial structure during regional ischemia and reperfusion. J Thorac Cardiovasc Surg. 1986;92(3 Pt 2):513–24.

    CAS  PubMed  Google Scholar 

  31. Taunyane IC, Benk C, Beyersdorf F, et al. Preserved brain morphology after controlled automated reperfusion of the whole body following normothermic circulatory arrest time of up to 20 minutes. Eur J Cardiothorac Surg. 2016;50(6):1025–34.

    Article  Google Scholar 

  32. Tolboom H, Makhro A, Rosser BA, Wilhelm MJ, Bogdanova A, Falk V. Recovery of donor hearts after circulatory death with normothermic extracorporeal machine perfusion. Eur J Cardiothorac Surg. 2015;47:173–9.

    Article  Google Scholar 

  33. Tolboom H, Olejnickova V, Reser D, Rosser B, Wilhelm MJ, Gassmann M, et al. Moderate hypothermia during ex vivo machine perfusion promotes recovery of hearts donated ater circulatory death. Eur J Cardiothorac Surg. 2016;49:25–31.

    Article  Google Scholar 

  34. Trivedi JR, Rajagopal K, Schumer EM, Birks EJ, Lenneman A, Cheng A, Slaughter MS. Differences in status 1A heart transplantation survival in the continuous flow left ventricular assist device era. Ann Thorac Surg. 2016;102:1512–6.

    Article  Google Scholar 

  35. Van Caenegem O, Beauloye C, Bertrand L, Horman S, Lepropre S, Sparavier G, et al. Hypothermic continuous machine perfusion enables preservation of energy charge and functional recovery of hearts grafts in an ex vivo model of donation following circulatory death. Eur J Cardiothorac Surg. 2016;49:1348–53.

    Article  Google Scholar 

  36. Warnecke G, et al. Organ Care System (OCS) Lung INSPIRE International Trial Results (abstract OLB05). Transplan Int. 2015;28(Suppl):131.3–4.

    Google Scholar 

  37. Yeung JC, et al. Outcomes after transplantation of lungs preserved for more than 12 h: retrospective study. Lancet Respiratory Med. 2016;5:119–24. https://doi.org/10.1016/S2213-2600(16)30323-X.

    Article  Google Scholar 

  38. Zimpfer D, Netuka I, Schmitto JD, Pya Y, Garbade M, Moshuis M, Beyersdorf F, Marasco S, Rao V, Damme L, Sood P, Krabatsch T. Multicentre clinical trial experience with the HeartMate 3 left ventricular assist device: 30-day outcomes. Eur J Cardiothorac Surg. 2016;50:548–54.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Friedhelm Beyersdorf .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this chapter

Check for updates. Verify currency and authenticity via CrossMark

Cite this chapter

Beyersdorf, F., Scheumann, J. (2019). Organ Preservation and Implantation. In: Feldman, D., Mohacsi, P. (eds) Heart Failure. Cardiovascular Medicine. Springer, Cham. https://doi.org/10.1007/978-3-319-98184-0_17

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-98184-0_17

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-98182-6

  • Online ISBN: 978-3-319-98184-0

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics