Skip to main content
Log in

Construction and performance test of prototype parallel plate avalanche counters at RAON

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

Two prototype position sensitive parallel plate avalanche counters (PPACs) have been fabricated at the Rare Isotope Science Project (RISP). Both detectors have active areas of 10 × 10 cm2 and utilize a stripped electrode structure, together with a delay line readout, to extract position information. Testing was conducted with an 241Am α source, and 2-dimensional position information was obtained. A position resolution of 0.55 mm full width at half maximum (FWHM), together with a position linearity of ±55 μm over a 67-mm detection range, were measured. A time resolution of 450 ps (FWHM) was also measured.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. E. Draper, Nucl. Instrum. Meth. 30, 148 (1964).

    Article  ADS  Google Scholar 

  2. K. Tshoo, H. Chae, J. Park, J. Y. Moon, Y. K. Kwon, G. A. Souliotis, T. Hashimoto, C. Akers, G. P. A. Berg, S. Choi, S. C. Jeong, S. Kato, Y. K. Kim, S. Kubono, K. B. Lee and C. B. Moon, Nucl. Instrum. Meth. B 376, 188 (2016).

    Article  ADS  Google Scholar 

  3. A. Zaghloul, Y. J. Kim, D. G. Kim, H. C. Jo and M. J. Kim, J. Korean Phys. Soc. 67, 1422 (2015).

    Article  ADS  Google Scholar 

  4. H. Stelzer, Nucl. Instrum. Meth. 133, 409 (1976).

    Article  ADS  Google Scholar 

  5. M. Nakhostin, Nucl. Instrum. Meth. A 615, 53 (2010).

    Article  ADS  Google Scholar 

  6. H. Kumagai, A. Ozawa, N. Fukuda, K. Summerer and I. Tanihata, Nucl. Instrum. Meth. A 470, 562 (2001).

    Article  ADS  Google Scholar 

  7. D. Harrach and H. J. Specht, Nucl. Instrum. Meth. 164, 477 (1979).

    Article  ADS  Google Scholar 

  8. H. Kumagai, T. Ohnishi, N. Fukuda, H. Takeda, D. Kameda, N. Inabe, K. Yoshida and T. Kubo, Nucl. Instrum. Meth. B 317, 717 (2013).

    Article  ADS  Google Scholar 

  9. J. F. Ziegler, M. Ziegler and J. Biersack, Nucl. Instrum. Meth. B 268, 1818 (2010).

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Charles Akers.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Akers, C., Lee, K.B., Kim, Y.J. et al. Construction and performance test of prototype parallel plate avalanche counters at RAON. Journal of the Korean Physical Society 70, 682–686 (2017). https://doi.org/10.3938/jkps.70.682

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.70.682

Keywords

Navigation