Abstract
The purpose of this study was to analyze the glottis rotational error (GRE) by using a thermoplastic mask for patients with the glottic cancer undergoing intensity-modulated radiation therapy (IMRT). We selected 20 patients with glottic cancer who had received IMRT by using the tomotherapy. The image modalities with both kilovoltage computed tomography (planning kVCT) and megavoltage CT (daily MVCT) images were used for evaluating the error. Six anatomical landmarks in the image were defined to evaluate a correlation between the absolute GRE (°) and the length of contact with the underlying skin of the patient by the mask (mask, mm). We also statistically analyzed the results by using the Pearson’s correlation coefficient and a linear regression analysis (P <0.05). The mask and the absolute GRE were verified to have a statistical correlation (P < 0.01). We found a statistical significance for each parameter in the linear regression analysis (mask versus absolute roll: P = 0.004 [P < 0.05]; mask versus 3D-error: P = 0.000 [P < 0.05]). The range of the 3D-errors with contact by the mask was from 1.2% - 39.7% between the maximumand no-contact case in this study. A thermoplastic mask with a tight, increased contact area may possibly contribute to the uncertainty of the reproducibility as a variation of the absolute GRE. Thus, we suggest that a modified mask, such as one that covers only the glottis area, can significantly reduce the patients’ setup errors during the treatment.
Similar content being viewed by others
References
S. M. Jackson, J. H. Hay and A. D. Flores, Radiother. Oncol. 59, 219 (2001).
W. M. Medenhall, R. J. Amdur, C. G. Morris and R. W. Hinerman. J. Clin. Oncol. 19, 4029 (2001).
X. Dai, Y. Zhao, Z. Liang, M. Dassarath, L. Wang, L. Jin, L. Chen, J. Dong, R. A. Price and C. M. Ma, Phys. Med. 31, 54 (2015).
S. J. Feigenberg, M. Lango, N. Nicolaou and J. A. Ridqe, Int. J. Radiat. Oncol. Biol. Phys. 68, 2 (2007).
D. L. Rosenthal et al., Int. J. Radiat. Oncol. Biol. Phys. 77, 455 (2010).
B. S. Chera, R. J. Amdur, C. G. Morris and W. M. Mendenhall, Int. J. Radiat. Oncol. Biol. Phys. 77, 1380 (2010).
S. O. Osman, H. C. de Boer, E. Astreinidou, A. Ganqsaas, B. J. Heijmen and P. C. Levendaq, Radiother. Oncol. 93, 8 (2009).
A. Tiong et al., J. Radiat. Oncol. 3, 267 (2013).
B. van Asselen, C. P. Raaijmakers, J. J. Laqendijk and C. H. Terhaard, Int. J. Radiat. Oncol. Biol. Phys. 56, 384 (2003).
L. Zhang et al., Int. J. Radiat. Oncol. Bio. Phys. 64, 1559 (2006).
S. van Kranen, S. van Beek, C. Rasch and J. J. Sonke, Int. J. Radiat. Oncol. Biol. Phys. 73, 1566 (2009).
K. Giske et al., Int. J. Radiat. Oncol. Biol. Phys. 80, 582 (2011).
Q. Zhang, W. Xiong, M. F. Chan, Y. Song and C. Burman, Phys. Med. 31, 80 (2015).
L. Glibeau, M. Octave-Prignot, T. Loncol, L. Renard, P. Scalliet and V. Gréqoire, Radiother. Oncol. 58, 155 (2001).
M. Fuss, B. J. Salter, D. Cheek, A. Sadeqhi, J. M. Hevezi and T. S. Herman, Radiother. Oncol. 71, 339 (2004).
D. Georg, J. Bogner, K. Dieckmann and R. Pötter, Int. J. Radiat. Oncol. Biol. Phys. 66, S61 (2006).
S. Kim, H. C. Akpati, J. G. Li, C. R. Liu, R. J. Amdur and J. R. Palta, Int. J. Radiat. Oncol. Biol. Phys. 59, 1531 (2004).
M. Zhang, Q. Zhang, H. Gan, S. Li and S. M. Zhou, Phys. Med. 32, 379 (2016).
L. Sharp, F. Lewin, H. Johansson, D. Payne, A. Gerhardsson and L. E. Rutqvist, Int. J. Radiat. Oncol. Biol. Phys. 61, 250 (2005).
G. Li et al., J. Appl. Clin. Med. Phys. 14, 243 (2013).
H. Inata, T. Semba, Y. ltoh, Y. Kuribayashi, S. Murayama, O. Nishizaki and F. Araki, Med. Phys. 39, 4219 (2012).
M. Velec, J. N. Waldron, B. O’Sullivan, A. Bayley, B. Cummings, J. J. Kim, J. Ringash, S. L. Breen, G. A. Lockwood and L. A. Dawson, Int. J. Radiat. Oncol. Biol. Phys. 76, 949 (2010).
C. R. Hansen, R. L. Christiansen, T. B. Nielsen, A. S. Bertelsen, J. Johansen and C. Brink, Acta Oncol. 53, 423 (2014).
K. J. Ruchala, G. H. Olivera, E. A. Schloesser and T. R. Mackie, Phys. Med. Biol. 44, 2597 (1999).
S. Yartsev, T. Kron and J. Van Dyk, Biomed. Imaging Interv. J. 3, 1 (2007).
A. Kaiser, T. E. Schultheiss, J. Y. Wong, D. D. Smith, C. Han, N. L. Vora, R. D. Pezner, Y. J. Chen and E. H. Radany, Int. J. Radiat. Oncol. Biol. Phys. 66, 949 (2006).
A. Rosset, L. Spadola and O. Ratib. J. Digit. Imaging 17, 205 (2004).
G. Kim, H. J. Jung, H. J. Lee, J. S. Lee, S. Koo and S. H. Chang, J. Digit. Imaging 25, 486 (2012).
J. Biomech, International. Society of Biomechanics. J. Biomech. 35, 543 (2002).
J. M. Bland and D. G. Altman, Lancet. 1, 307 (1986).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jung, J.H., Jung, JY., Cho, K.H. et al. Relevant reduction effect with a modified thermoplastic mask of rotational error for glottic cancer in IMRT. Journal of the Korean Physical Society 70, 308–316 (2017). https://doi.org/10.3938/jkps.70.308
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.3938/jkps.70.308