Abstract
Internal radiation dose assessment involves biokinetic models, the corresponding parameters, measured data, and many assumptions. Every component considered in the internal dose assessment has its own uncertainty, which is propagated in the intake activity and internal dose estimates. For research or scientific purposes, and for retrospective dose reconstruction for accident scenarios occurring in workplaces having a large quantity of unsealed radionuclides, such as nuclear power plants, nuclear fuel cycle facilities, and facilities in which nuclear medicine is practiced, a quantitative uncertainty assessment of the internal dose is often required. However, no calculation tools or computer codes that incorporate all the relevant processes and their corresponding uncertainties, i.e., from the measured data to the committed dose, are available. Thus, the objective of the present study is to develop an integrated probabilistic internal-dose-assessment computer code. First, the uncertainty components in internal dosimetry are identified, and quantitative uncertainty data are collected. Then, an uncertainty database is established for each component. In order to propagate these uncertainties in an internal dose assessment, a probabilistic internal-dose-assessment system that employs the Bayesian and Monte Carlo methods. Based on the developed system, we developed a probabilistic internal-dose-assessment code by using MATLAB so as to estimate the dose distributions from the measured data with uncertainty. Using the developed code, we calculated the internal dose distribution and statistical values (e.g. the 2.5th, 5th, median, 95th, and 97.5th percentiles) for three sample scenarios. On the basis of the distributions, we performed a sensitivity analysis to determine the influence of each component on the resulting dose in order to identify the major component of the uncertainty in a bioassay. The results of this study can be applied to various situations. In cases of severe internal exposure, the causation probability of a deterministic health effect can be derived from the dose distribution, and a high statistical value (e.g., the 95th percentile of the distribution) can be used to determine the appropriate intervention. The distribution-based sensitivity analysis can also be used to quantify the contribution of each factor to the dose uncertainty, which is essential information for reducing and optimizing the uncertainty in the internal dose assessment. Therefore, the present study can contribute to retrospective dose assessment for accidental internal exposure scenarios, as well as to internal dose monitoring optimization and uncertainty reduction.
Similar content being viewed by others
References
National Council on Radiation Protection & Measurements (NCRP), NCRP Report No. 164 (2009).
W. B. Li, W. Klein, E. Blanchardon, M. Puncher, R. W. Leggett, U. Oeh, B. Breustedt, D. Noßke and M. A. Lopez, Rad. Prot. Dosim. 163, 37 (2015).
D. M. Hamby and R. R. Benke, Rad. Prot. Dosim. 82, 245 (1999).
A. I. Apostoaei, Determination of the Uncertainties in Radiation Doses from Ingestion of 90Sr (University of Tennessee, 2011).
R. P. Harvey and D. M. Hamby, Rad. Prot. Dosim. 95, 239 (2001).
C. M. Catellani, J. W. Marsh, C. Hurtgen, E. Blanchardon, P. Berard, A. Giussani and M. A. Lopez, EURADOS Report 2013-01 (2013).
M. D. Dorrian and M. R. Bailey, Rad. Prot. Dosim. 60, 119 (1995).
International Commission on Radiological Protection (ICRP), ICRP Publication 66 (1994).
International Commission on Radiological Protection (ICRP), ICRP Publication 30 (1979).
International Commission on Radiological Protection (ICRP), ICRP Publication 67 (1993).
A. I. Apostoaei and L. F. Miller, Health Phys. 86, 460 (2004).
International Commission on Radiological Protection (ICRP), ICRP Publication 23 (1975).
M. D. Mckay, R. J. Beckman and W. J. Conover, Technometrics 21, 239 (1979).
A. C. James, A. Birchall, J. W. Marsh, M. Puncher, IMBA Professional Plus User Manual (Health Physics Association, 2005).
D. M. Hamby, Enviro. Monit. Assessment 33, 135 (1994).
International Commission on Radiological Protection (ICRP), ICRP Publication 60 (1991).
International Commission on Radiological Protection (ICRP), ICRP Publication 130 (2016).
International Atomic Energy Agency (IAEA), IAEATECDOC- 1568 (2007).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Noh, S., Kwon, TE. & Lee, JK. Development of probabilistic internal dosimetry computer code. Journal of the Korean Physical Society 70, 252–261 (2017). https://doi.org/10.3938/jkps.70.252
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.3938/jkps.70.252