Skip to main content
Log in

Optimization of the multi-turn injection efficiency for a medical synchrotron

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

We present a method for optimizing the multi-turn injection efficiency for a medical synchrotron. We show that for a given injection energy, the injection efficiency can be greatly enhanced by choosing transverse tunes appropriately and by optimizing the injection bump and the number of turns required for beam injection. We verify our study by applying the method to the Korea Heavy Ion Medical Accelerator (KHIMA) synchrotron which is currently being built at the campus of Dongnam Institute of Radiological and Medical Sciences (DIRAMS) in Busan, Korea. First the frequency map analysis was performed with the help of the ELEGANT and the ACCSIM codes. The tunes that yielded good injection efficiency were then selected. With these tunes, the injection bump and the number of turns required for injection were then optimized by tracking a number of particles for up to one thousand turns after injection, beyond which no further beam loss occurred. Results for the optimization of the injection efficiency for proton ions are presented.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. T. Okada et al., J. Rad. Re. 51, 355 (2010).

    Article  Google Scholar 

  2. H. Giap and B. Giap, Transl. Cancer Res. 1, 127 (2012).

    Google Scholar 

  3. PIMMS Group, Proton-Ion Medical Machine Study (PIMMS), Part I, Part II, CERN-PS/99-010 (Geneva, Switzerland, 2000).

    Google Scholar 

  4. H. Yim, D. H. An, G. H. Hahn, C. Park and G.-B. Kim, J. Korean Phys. Soc. 67, 1364 (2015).

    Article  ADS  Google Scholar 

  5. G. H. Rees, 5th General Accelerator Physics Course, CERN Accelerator School 1992, Jyväskylä, Finland, CERN 94-01 vol. II (Geneva, Switzerland, 1994).

    Google Scholar 

  6. M. Borland, Argonne National Laboratory Advanced Photon Source Report APS LS-287, 2000.

    Google Scholar 

  7. F. W. Jones, TRIUMF Design Note, TRI-DN-90-17 (1990).

    Google Scholar 

  8. W. Daqa, I. Hofmann and J. Struckmeier, in Proceedings of IPAC 2011 (San Sebastián, Spain, 2011), p. 3490.

    Google Scholar 

  9. I. Hofmann, Phys. Rev. E 57, 4713 (1998).

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Yoon.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, J., Yoon, M. & Yim, H. Optimization of the multi-turn injection efficiency for a medical synchrotron. Journal of the Korean Physical Society 69, 927–932 (2016). https://doi.org/10.3938/jkps.69.927

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.69.927

Keywords

Navigation