Abstract
As an attempt to develop a gamma-ray/neutron dual-particle imager, we employed a rotating modulation collimator (RMC) coupled to a pulse shape discrimination-capable scintillator. We performed fundamental simulations on the proposed RMC system utilizing a CLYC detector to verify the basic properties of the RMC system and to optimize the computing methods for the Monte Carlo simulation. We obtained batches of modulation patterns for various source locations by using Monte Carlo N-Particle simulations, and we studied the characteristics of the modulation patterns, such as the rotational effect, the shift effect, and the symmetric effect. We compared simulated modulation patterns with those obtained from the mathematical model of the RMC system to investigate the feasibility of identifying the source location correctly based on the simulated patterns. When a source was located in the far-field region, the modulation patterns showed good agreement between the Monte Carlo simulation and the mathematical model. The results hold promises for reconstructing gamma and neutron images of radioactivity by using a RMC system on a CLYC detector.
Similar content being viewed by others
References
M. Oda, App. Opt. 4, 000143 (1965).
H. S. Kim, H. Y. Choi, G. Lee, S. J. Ye and G. Kim, Monte Carlo Simulation of Rotational Modulation Collimator (RMC) Patterns for the Gamma-Ray/Neutron Dual-Particle Imager, in Proceeding of the 2015 IEEE NSS/MIC/RTSD (San Diego, USA. October 31-November 7, 2015).
G. J. Hurford, E. J. Schmahl, R. A. Schwartz, A. J. Conway, M. J. Aschwanden, A. Csillaghy, B. R. Dennis, C. Johns-Krull, S. Krucker et al., The RHESSI Imaging Concept (Kluwer Academic Publishers, Berlin, Germany, 2002).
A. C. Sharma, G. D. Tourassi, A. J. Kapadia, B. P. Harrawood, J. E. Bender, A. S. Crowell, M. R. Kiser, C. R. Howell and C. E. Floyd Jr., IEEE Trans. Nucl. Sci. 54, 906058 (2007).
B. R. Kowash and D. K. Wehe, Nucl. Instr. Meth. A 637, 037 (2011).
J. Glodo, R. Hawrami and K. S. Shah, J. Cryst. Growth. 379, 023 (2013).
H. S. Kim, M. B. Smith, S. W. Kwak, S. J. Ye and G. Kim, J. Radiat. Prot. Res. (to be published).
D. B. Pelowitz, MCNP6 user’s manual version 1.0 (Los Alamos National Laboratory, NM, USA, 2013).
D. M. Smith, G. J. Hurford and S. E. Boggs. New Astron. 48, 030 (2004).
Y. Shin, G. Kim and G. Lee, J. IEIE 53, 118 (2016).
M. J. Berger and J. H. Hubbell, XCOM: Photon cross sections version 1.2 (National Institute of Standards and Technology, MD, USA, 1999).
Y. Shin, G. Kim and G. Lee, Improving rotating modulation collimator imaging algorithm using regularization, in Proceeding of the 2016 IEIE (Jeju, Korea, Jun. 22-24, 2016).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kim, H.S., Ye, SJ., Shin, Y. et al. Radiation imaging with a rotational modulation collimator (RMC) coupled to a Cs2LiYCl6:Ce (CLYC) detector. Journal of the Korean Physical Society 69, 1644–1650 (2016). https://doi.org/10.3938/jkps.69.1644
Received:
Published:
Issue Date:
DOI: https://doi.org/10.3938/jkps.69.1644
Keywords
- Rotational modulation collimator
- CLYC scintillator
- Pulse shape discrimination
- Monte Carlo simulation
- Radiation imaging