Abstract
The Monte Carlo N-Particle Transport Code is adopted for numerical calculations and simulation analyses of the parameters for the designed irradiation facility for human blood (including the neutron moderator and its thickness, the neutron source’s location, and the collimator’s radius) and of the parameters for the unit for measuring human blood (such as the crystal thickness and radius of NaI) to measure the activity of 24Na in the human body exposed to neutron irradiation in nuclear accidents. Calculation results show that the most suitable parameters for the irradiation facility for human blood include 6-cm polyethylene as the neutron moderator, collimator radius of 7 mm, and a neutron source placed at the bottom of the collimator. However, the parameters for the unit to measure human blood are as follows: both the thickness and the radius of the crystal at the bottom of the NaI detector are 5 cm. The effectiveness of the design parameters was verified by using actual experiments.
References
Y. Feng, L. F. Miller, K. S. Brown, W. H. Casson, G. T. Mei and M. Thein, Oak Ridge National Laboratory Report No. ORNL/TM-12028, 1993.
S. M. Luo, Chin. J. Radiol. Med. Prot. 17, 338 (1997).
T. Momose, N. Tsujimura, T. Tasaki, K. Kanai, O. Kurihara, N. Hayashi and K. Shinohara, J. Radiat. Res. 42 Suppl, S95 (2001).
F. Takahashi, A. Endo and Y. Yamaguchi, J. Nucl. Sci. Technol. 42, 378 (2005).
J. Cheng and X. D. Xie, Chin. J. Radiol. Health 20, 118 (2011).
J. Cheng, H. J. Nan and J. Ning, Chin. J. Radiol. Health 20, 238 (2011).
Y. X. Wang, Y. F. Yang, Y. J. Lu, J. G. Zhang and H. C. Xing, Chin. J. Radiol. Medi. Prot. 31, 67 (2011).
C. L. Liu, Master thesis, Chengdu University of Technology, 2011.
J. Z. Zhang, X. G. Tuo, Z. Li and C. L. Liu, Nucl. Tech. 35, 661 (2012).
J. W. Shin, S. W. Hong, S. I. Bak, D. Y. Kim and Y. K. Chong, J. Korean Phys. Soc. 65, 591 (2014).
J. Z. Zhang, X. G. Tuo, Z. Li, L. Li and Z. X. Wan, High Pow. Las. Part. Beam 25, 189 (2013).
Y. F. Yang, K. Zhang, Y. X. Wang, Z. T. Wang and H. J. Wang, Nucl. Electr. Dete. Tech. 35, 350 (2015).
J. F. Briesmeister, Los Alamos National Laboratory Report No. LA-13709-M, 2000.
C. Oliveira, J. Salgado and F. G. Carvallio, J. Radioanal Nucl. Chem. 216, 191 (1997).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Yang, JB., Li, R., Liu, Z. et al. Optimized design of a facility for measuring sodium-24 in blood by using Monte Carlo simulations. Journal of the Korean Physical Society 68, 939–943 (2016). https://doi.org/10.3938/jkps.68.939
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.3938/jkps.68.939