Skip to main content
Log in

Optimized design of a facility for measuring sodium-24 in blood by using Monte Carlo simulations

  • Letters
  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

The Monte Carlo N-Particle Transport Code is adopted for numerical calculations and simulation analyses of the parameters for the designed irradiation facility for human blood (including the neutron moderator and its thickness, the neutron source’s location, and the collimator’s radius) and of the parameters for the unit for measuring human blood (such as the crystal thickness and radius of NaI) to measure the activity of 24Na in the human body exposed to neutron irradiation in nuclear accidents. Calculation results show that the most suitable parameters for the irradiation facility for human blood include 6-cm polyethylene as the neutron moderator, collimator radius of 7 mm, and a neutron source placed at the bottom of the collimator. However, the parameters for the unit to measure human blood are as follows: both the thickness and the radius of the crystal at the bottom of the NaI detector are 5 cm. The effectiveness of the design parameters was verified by using actual experiments.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Y. Feng, L. F. Miller, K. S. Brown, W. H. Casson, G. T. Mei and M. Thein, Oak Ridge National Laboratory Report No. ORNL/TM-12028, 1993.

    Google Scholar 

  2. S. M. Luo, Chin. J. Radiol. Med. Prot. 17, 338 (1997).

    Google Scholar 

  3. T. Momose, N. Tsujimura, T. Tasaki, K. Kanai, O. Kurihara, N. Hayashi and K. Shinohara, J. Radiat. Res. 42 Suppl, S95 (2001).

    Article  Google Scholar 

  4. F. Takahashi, A. Endo and Y. Yamaguchi, J. Nucl. Sci. Technol. 42, 378 (2005).

    Article  Google Scholar 

  5. J. Cheng and X. D. Xie, Chin. J. Radiol. Health 20, 118 (2011).

    Google Scholar 

  6. J. Cheng, H. J. Nan and J. Ning, Chin. J. Radiol. Health 20, 238 (2011).

    Google Scholar 

  7. Y. X. Wang, Y. F. Yang, Y. J. Lu, J. G. Zhang and H. C. Xing, Chin. J. Radiol. Medi. Prot. 31, 67 (2011).

    Google Scholar 

  8. C. L. Liu, Master thesis, Chengdu University of Technology, 2011.

    Google Scholar 

  9. J. Z. Zhang, X. G. Tuo, Z. Li and C. L. Liu, Nucl. Tech. 35, 661 (2012).

    Google Scholar 

  10. J. W. Shin, S. W. Hong, S. I. Bak, D. Y. Kim and Y. K. Chong, J. Korean Phys. Soc. 65, 591 (2014).

    Article  ADS  Google Scholar 

  11. J. Z. Zhang, X. G. Tuo, Z. Li, L. Li and Z. X. Wan, High Pow. Las. Part. Beam 25, 189 (2013).

    Article  Google Scholar 

  12. Y. F. Yang, K. Zhang, Y. X. Wang, Z. T. Wang and H. J. Wang, Nucl. Electr. Dete. Tech. 35, 350 (2015).

    MathSciNet  Google Scholar 

  13. J. F. Briesmeister, Los Alamos National Laboratory Report No. LA-13709-M, 2000.

    Google Scholar 

  14. C. Oliveira, J. Salgado and F. G. Carvallio, J. Radioanal Nucl. Chem. 216, 191 (1997).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jian-Bo Yang.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yang, JB., Li, R., Liu, Z. et al. Optimized design of a facility for measuring sodium-24 in blood by using Monte Carlo simulations. Journal of the Korean Physical Society 68, 939–943 (2016). https://doi.org/10.3938/jkps.68.939

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.68.939

Keywords

Navigation