Skip to main content
Log in

Development of a patient positioning error compensation tool for Korea Heavy-Ion Medical Accelerator Treatment Center

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

In this study, a potential validation tool for compensating for the patient positioning error was developed by using 2D/3D and 3D/3D image registration. For 2D/3D registration, digitallyreconstructed radiography (DRR) and three-dimensional computed tomography (3D-CT) images were applied. The ray-casting algorithm is the most straightforward method for generating DRR, so we adopted the traditional ray-casting method, which finds the intersections of a ray with all objects, voxels of the 3D-CT volume in the scene. The similarity between the extracted DRR and the orthogonal image was measured by using a normalized mutual information method. Two orthogonal images were acquired from a Cyber-knife system from the anterior-posterior (AP) and right lateral (RL) views. The 3D-CT and the two orthogonal images of an anthropomorphic phantom and of the head and neck of a cancer patient were used in this study. For 3D/3D registration, planning CT and in-room CT images were applied. After registration, the translation and the rotation factors were calculated to position a couch to be movable in six dimensions. Registration accuracies and average errors of 2.12 mm ± 0.50 mm for transformations and 1.23 ° ± 0.40 ° for rotations were acquired by using 2D/3D registration with the anthropomorphic Alderson-Rando phantom. In addition, registration accuracies and average errors of 0.90 mm ± 0.30 mm for transformations and 1.00 ° ± 0.2 ° for rotations were acquired by using CT image sets. We demonstrated that this validation tool could compensate for patient positioning errors. In addition, this research could be a fundamental step in compensating for patient positioning errors at the Korea Heavy-ion Medical Accelerator Treatment Center.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. X. Chen, M. R. Varley, L. K. Shark, G. S. Shentall and M. C. Kirby, Phys. Med. Biol. 53, 967 (2008).

    Article  Google Scholar 

  2. T. Mitin and A. L. Zietman, J. Clin. Oncol. 30, 2855 (2014).

    Article  Google Scholar 

  3. D. Schulz-Ertner and H. Tsujii, J. Clin. Oncol. 25, 953 (2007).

    Article  Google Scholar 

  4. T. Terasawa, T. Dvorak, S. Ip, G. Raman, J. Lau and T. A. Trikalinos, Ann. Intern. Med. 151, 556 (2009).

    Article  Google Scholar 

  5. C. T. Metz, Digitally Reconstructed Radiographs (Utrecht University, INF/SCR-04-72, 2006).

  6. A. Chovanec, Digitally Reconstructed Radiographs (Charles University in Prague, Bachelor Thesis, 2009).

    Google Scholar 

  7. W. Birkfellner et al., Phys. Med. Biol. 48, 2665 (2003).

    Article  Google Scholar 

  8. L. Zollei, 2D-3D Rigid-Body Registration of X-ray Fluoscopy and C Images (Massachusetts institute of technology, Bachelor Thesis, 2011).

    Google Scholar 

  9. L. Lemieux, R. Jagoe, D. R. Fish, N. D. Kitchen and D. G. T. Thomas, Med. Phys. 21, 1749 (1994).

    Article  Google Scholar 

  10. C. Yang, M. Guiney, P. Hughes, S. Leung, K. H. Liew, J. Matar and G. Quong, Australas. Radiol. 44, 439 (2000).

    Article  Google Scholar 

  11. C. Antypas and E. Pantelis, Phys. Med. Biol. 53, 4697 (2008).

    Article  Google Scholar 

  12. D. B. Russakoff, T. Rohlfing, K. Mori, D. Rueckert, A. Ho, J. R. Adler Jr., C. R. Maurer Jr., IEEE Trans. Med. Imaging. 24, 1441 (2005).

    Article  Google Scholar 

  13. X. Chen, R. Gilkeson and B. Fei, Proc. SPIE. 6512, 65120A (2007).

    Article  ADS  Google Scholar 

  14. C. Bethune and A. J. Stewart, Int. Congr. Ser. 1281, 98 (2005).

    Article  Google Scholar 

  15. C. Men, X. Gu, D. Choi, A. Majumdar, Z. Zheng, K. Mueller and S. B. Jiang, Phys. Med. Biol. 54, 6287 (2009).

    Article  Google Scholar 

  16. X. Jia, X. Gu, Y. J. Graves, M. Folkerts and S. B. Jiang, Phys. Med. Biol. 56, 7017 (2011).

    Article  Google Scholar 

  17. Y. H. Na, T. S. Suh, D. S. Kapp and L. Xing, Phys. Med. Biol. 58, 6525 (2013).

    Article  Google Scholar 

  18. H. Wang, Y. Ma, G. Pratx and L. Xing, Phys. Med. Biol. 56, N175 (2011).

    Article  Google Scholar 

  19. J. Z. Liang et al., Cancer imaging: instrumentation and application (Academic Press, Waltham, Massachusetts, 2007).

    Google Scholar 

  20. K. M. Hanson, IEEE Trans. Nucl. Sci. NS26, 1635 (1979).

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tae-Suk Suh.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, MJ., Suh, TS., Cho, W. et al. Development of a patient positioning error compensation tool for Korea Heavy-Ion Medical Accelerator Treatment Center. Journal of the Korean Physical Society 67, 204–208 (2015). https://doi.org/10.3938/jkps.67.204

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.67.204

Keywords

Navigation